Page 67
3 Symbologies
Introduction Use this section to program the hand-held Imager. This programming section contains the following menuing selections: • Linear Symbology Selections • Stacked Symbology Selections • Postal Symbology Selections • 2D Matrix Symbology Selections • Diagnostics
3-1
Page 68
Linear Symbologies Codabar <Default All Codabar Settings>
Codabar
* On
Off
Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters.
Start/Stop Transmit
* Don’t Transmit Start/Stop
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3-2
Page 69
Linear Symbologies Codabar, continued Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, But Don’t Transmit, the unit will only read Codabar bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate, And Transmit, the scanner will only read Codabar bar codes printed with a check character, and will transmit this character at the end of the scanned data.
* No Check Character
Validate, But Don’t Transmit
Validate, And Transmit
3-3
Page 70
Linear Symbologies Code 39 < Default All Code 39 Settings >
Code 39
* On
Off
Start/Stop Characters Start/Stop characters identify the leading and trailing ends of the bar code. You may either transmit, or not transmit Start/Stop characters.
Transmit
* Don’t Transmit
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Maximum Message Length Message Length A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3-4
Page 71
Linear Symbologies Code 39, continued Full ASCII If Full ASCII Code 39 decoding is turned on, certain character pairs within the bar code symbol will be interpreted as a single character. For example: $V will be decoded as the ASCII character SYN, and /C will be decoded as the ASCII character #. NUL %U
DLE $P
SP
SPACE 0
0
@
%V
P
P
‘
W p
+P
SOH $A
DC1 $Q
!
/A
1
1
A
A
Q
Q a
+A q
+Q
STX $B
DC2 $R
“
/B
2
2
B
B
R
R b
+B r
+R
ETX $C
DC3 $S
#
/C
3
3
C
C
S
S c
+C s
+S
EOT $D
DC4 $T
$
/D
4
4
D
D
T
T d
+D t
+T
ENQ $E
NAK $U
%
/E
5
5
E
E
U
U e
+E u
+U
ACK $F
SYN $V
&
/F
6
6
F
F
V
V f
+F v
+V
BEL $G
ETB $W
‘
/G
7
7
G
G
W
W g
+G w
+W
BS
$H
CAN $X
(
/H
8
8
H
H
X
X h
+H x
+X
HT
$I
EM
$Y
)
/I
9
9
I
I
Y
Y i
+I y
+Y
LF
$J
SUB $Z
*
/J
:
/Z
J
J
Z
Z j
+J z
+Z
VT
$K
ESC %A
+
/K
;
%F
K
K
[
%K k
+K
{
%P
FF
$L
FS
%B
,
/L
<
%G L
L
\
%L l
+L
|
%Q
CR
$M
GS
%C
-
-
=
%H
M
M
]
%M m
+M
}
%R
SO
$N
RS
%D
.
.
>
%I
N
N
^
%N n
+N
~
%S
SI
$O
US
%E
/
/O
?
%J
O
O
_
%0 o
+O
DEL %T
Character pairs /M and /N decode as a minus sign and period respectively. Character pairs /P through /Y decode as 0 through 9.
Full ASCII On
* Full ASCII Off
3-5
Page 72
Linear Symbologies Code 39, continued Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character. When Check Character is set to Validate, But Don’t Transmit, the unit will only read Code 39 bar codes printed with a check character, but will not transmit the check character with the scanned data. When Check Character is set to Validate, And Transmit, the scanner will only read Code 39 bar codes printed with a check character, and will transmit this character at the end of the scanned data.will transmit this character at the end of the scanned data.
* No Check Character
Validate, But Don’t Transmit
3-6
Validate, And Transmit
Page 73
Linear Symbologies Interleaved 2 of 5 < Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3-7
Page 74
Linear Symbologies Interleaved 2 of 5, continued Check Digit When Check Digit is set to Validate, But Don’t Transmit, the unit will only read Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the check digit with the scanned data. When Check Digit is set to Validate, And Transmit, the scanner will only read Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit at the end of the scanned data.
* No Check Digit
Validate, But Don’t Transmit
3-8
Validate, And Transmit
Page 75
Linear Symbologies Iata 2 of 5 < Default All Iata 2 of 5 Settings >
Iata 2 of 5
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).