Page 76
Linear Symbologies Code 93 < Default All Code 93 Settings >
Code 93
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Message Length
Maximum Message Length
A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 10
Page 77
Linear Symbologies Code 128 < Default All Code 128 Settings >
Code 128
* On
Off
Message Length The message length selection is used to set the valid reading length of the bar code. If the data length of the scanned bar code doesn’t match the valid reading length, the scanner will issue an error beep. You may wish to set the same value for minimum and maximum length to force the scanner to read fixed length bar code data. This helps reduce the chances of a misread. EXAMPLE: Decode only those bar codes with a count of 9-20 characters. Min. length = 09 Max. length = 20 EXAMPLE: Decode only those bar codes with a count of 15 characters. Min. length = 15 Max. length = 15
Minimum Maximum Message Length Message Length A one- to two-digit number and Save are required after reading this programming symbol. Refer to the Programming Chart (inside back cover).
3 - 11
Page 78
Linear Symbologies ISBT Scan the On code below if you wish to decode ISBT bar codes. (ISBT codes are a combination of multiple linear symbols used to mark blood bags.)
On
3 - 12
* Off
Page 79
Linear Symbologies EAN/JAN 8 < Default All EAN/JAN 8 Settings >
EAN/JAN 8
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
Transmit Check Digit
* Don’t Transmit Check Digit
3 - 13
Page 80
Linear Symbologies EAN/JAN 13 < Default all EAN/JAN 13 Settings >
EAN/JAN 13
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
Transmit Check Digit
3 - 14
* Don’t Transmit Check Digit
Page 81
Linear Symbologies EAN Addenda You can add 2 or 5 digits to the end of all scanned EAN data (EAN 8 and EAN 13).
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
3 - 15
Page 82
Linear Symbologies UPC A < Default All UPC A Settings >
UPC A
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
Transmit Check Digit
* Don’t Transmit Check Digit
Number System The numeric system digit of a UPC symbol is normally transmitted, but the unit can be programmed so it will not transmit it.
* Transmit Number System
3 - 16
Don’t Transmit Number System
Page 83
Linear Symbologies UPC E0 < Default All UPC E0 Settings >
UPC E0 Most UPC bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes which lead with the 1 number system, use the UPC E1 selection.
* On
Off
Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not.
Transmit Check Digit
* Don’t Transmit Check Digit
Number System The numeric system digit of a UPC symbol is normally transmitted, but the unit can be programmed so it will not transmit it.
Transmit Number System
* Don’t Transmit Number System
3 - 17
Page 84
Linear Symbologies UPC E0, continued Version E Expand Version E Expand, expands the UPC-E code to the 12 digit, UPC-A format.
Expand
* Don’t Expand
UPC E1 Most UPC bar codes lead with the 0 number system. For these codes, use the UPC E0 selection. If you need to read codes which lead with the 1 number system, use the UPC E1 selection.
* On
Off
UPC Addenda You can add 2 or 5 digits to the end of all scanned UPC data (UPC A, UPC E0, and UPC E1).
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
3 - 18