Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 19

4800p 2D Imager User's Guide, pages 141 to 150

Pages 141 to 150 of 184

The original document is the PDF (918 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the HHP 4800p and Honeywell 4800p

Page 141

Examples of Query Commands In the following examples, a bracketed notation [ ] depicts a non-displayable response.

Example #1:What is the range of possible values for Codabar Coding Enable? Enter: cbrena*. Response: CBRENA0-1[ACK] This response indicates that Codabar Coding Enable (CBRENA) has a range of values from 0 to 1 (off and on).

Example #2: What is the default value for Codabar Coding Enable? Enter: cbrena^. Response: CBRENA1[ACK] This response indicates that the default setting for Codabar Coding Enable (CBRENA) is 1, or on.

Example #3: What is the device’s current setting for Codabar Coding Enable? Enter: cbrena?. Response: CBRENA1[ACK] This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on.

Example #4: What are the device’s settings for all Codabar selections? Enter: cbr?. Response: CBRENA1[ACK], SSX0[ACK], CK20[ACK], CCT1[ACK], MIN2[ACK], MAX60[ACK], DFT[ACK]. This response indicates that the device’s Codabar Coding Enable (CBRENA) is set to 1, or on; the Start/Stop Character (SSX) is set to 0, or Don’t Transmit; the Check Character (CK2) is set to 0, or Not Required; concatenation (CCT) is set to 1, or Enabled; the Minimum Message Length (MIN) is set to 2 characters; the Maximum Message Length (MAX) is set to 60 characters; and the Default setting (DFT) has no value.

11 - 3

Page 142

Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Standard Product Default Settings bar code below.

Standard Product Default Settings The chart on the following pages lists the factory default settings for each of the menu commands (indicated by an asterisk (*) on the programming pages).

Menu Commands Note: Not all menu commands apply to all imager models.

Selection

Factory Default Settings

Setting * Indicates default

Default

Serial Command # Indicates a numeric entry DEFALT

Page

11-4

Terminal Interfaces Terminal ID

*130

TERMID###

2-1

Output Selections Beeper - Good Read Beeper Volume Good Read

Beeper Pitch - Good Read (Frequency)

Beeper Duration Good Read

11 - 4

Off

BEPBEP0

3-1

*On

BEPBEP1

3-1

Off

BEPLVL0

3-1

Low

BEPLVL1

3-1

Medium

BEPLVL2

3-1

*High

BEPLVL3

3-1

Low (1600) (min 400Hz)

BEPFQ11600

3-2

*Medium (3250)

BEPFQ13250

3-2

High (4200) (max 9000Hz)

BEPFQ14200

*Normal Beep

BEPBIP0

3-2

Short Beep

BEPBIP1

3-2

3-2

Page 143

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

Number of Beeps Good Read

*1

BEPRPT1

3-2

Range 1 - 9

BEPRPT#

3-2

Good Read Delay

*No Delay

DLYGRD0

3-3

Short Delay (500 ms)

DLYGRD500

3-3

Medium Delay (1000 ms)

DLYGRD1000

3-3

Long Delay (1500 ms)

DLYGRD1500

3-3 3-3

User-Specified Good Read Delay

Range 0 - 30,000 ms

Reread Delay

Short (500 ms)

DLYRRD500

3-4

*Medium (750 ms)

DLYRR750

3-4

Long (1000 ms)

DLYRRD1000

3-4

Extra Long (2000 ms)

DLYRRD2000

3-4

User-Specified Reread Delay LED Power Level

Centering Window

Decode Search Mode

Range 0 - 30,000 ms

DLYGRD#####

DLYRRD#####

3-4

Off

PWRLDC0

3-5

Low (50%)

PWRLDC50

3-5

*High (100%)

PWRLDC100

3-5

Centering On

DECWIN1

3-6

*Centering Off

DECWIN0

3-6

Left of Centering Window (*40%)

DECLFT

Right of Centering Window (*60%)

DECRGT

Top of Centering Window (*40%)

DECTOP

Bottom of Centering Window (*60%)

DECBOT

*Full Omnidirectional (Default for 2D imagers)

DECMOD0

Quick Omnidirectional

DECMOD1

Advanced Linear Decoding (Default for PDF imagers)

DECMOD2

3-6 3-6 3-6 3-6 3-7 3-7 3-7

11 - 5

Page 144

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

Output Sequence Editor

Enter Sequence

SEQBLK

3-10

Default Sequence

SEQDFT

3-10

Require Output Sequence

Required

SEQ_EN2

3-11

On/Not Required

SEQ_EN1

3-11

*Off

SEQ_EN0

3-11

Set Print Weight (1-7)

PRTWGT

3-11

*Default (4)

PRTWGT4

3-11

On

VIDREV1

3-12

*Off

VIDREV0

3-12

*Upright

ROTATN0

3-13

Rotate Code Clockwise 90°

ROTATN1

Upside Down

ROTATN2

Rotate Code Counterclockwise 90°

ROTATN3

Print Weight Video Reverse Working Orientation

3-13 3-13 3-13

Prefix/Suffix Selections Add CR Suffix to All Symbologies

VSUFCR

4-3

Prefix

Add Prefix

PREBK2##

4-4

Clear One Prefix

PRECL2

4-4

Clear All Prefixes

PRECA2

4-4

Add Suffix

SUFBK2##

4-4

Clear One Suffix

SUFCL2

4-4

Suffix

Clear All Suffixes

SUFCA2

4-4

Function Code Transmit

*Enable

RMVFNC0

4-4

Disable

RMVFNC1

4-4

Intercharacter Delay

Range 0 - 495 ms

DLYCHR##

4-5

User Specified Intercharacter Delay

Delay Length (0 - 495 ms)

DLYCRX##

Character to Trigger Delay

DLY_XX###

Interfunction Delay

Range 0 - 495 ms

DLYFNC##

4-6

Intermessage Delay

Range 0 - 495 ms

DLYMSG##

4-7

11 - 6

4-6 4-6

Page 145

Selection

Setting * Indicates default

Serial Command # Indicates a numeric entry

Page

Data Formatter Selections Data Format Editor

Data Formatter

*Default Data Format (None)

DFMDF3

5-4

Enter Data Format

DFMBK3##

5-4

Clear One Data Format

DFMCL3

5-4

Clear All Data Formats

DFMCA3

5-4

Off

DFM_EN0

5-5

*On, but Not Required

DFM_EN1

5-5

On, Required

DFM_EN2

5-5

1

VSAF_1

5-5

2

VSAF_2

5-5

3

VSAF_3

5-5

All Symbologies

All Symbologies Off

ALLENA0

6-2

All Symbologies On

ALLENA1

6-2

Codabar

Default All Codabar Settings

CBRDFT

Alternate Data Formats

Symbologies

Codabar

6-3

Off

CBRENA0

6-3

*On

CBRENA1

6-3

Codabar Start/Stop Char.

*Don’t Transmit

CBRSSX0

6-3

Transmit

CBRSSX1

6-3

Codabar Check Char.

*No Check Char.

CBRCK20

6-4

Validate, But Don’t Transmit

CBRCK21

Validate, and Transmit

CBRCK22

6-4

*Off

CBRCCT0

6-4

On

CBRCCT1

6-4

Require

CBRCCT2

6-4

Minimum (2 - 60) *4

CBRMIN##

6-5

Maximum (2 - 60) *60

CBRMAX##

6-5

Codabar Concatenation

Codabar Message Length

6-4

11 - 7

Page 146

Selection

Setting * Indicates default

Serial Command # Indicates a numeric entry

Page

Code 39

Default All Code 39 Settings

C39DFT

6-5

Code 39

Off

C39ENA0

6-5

*On

C39ENA1

6-5

Code 39 Start/Stop Char.

*Don’t Transmit

C39SSX0

6-5

Transmit

C39SSX1

6-5

Code 39 Check Char.

*No Check Char.

C39CK20

6-6

Validate, But Don’t Transmit

C39CK21

Validate, and Transmit

C39CK22

Code 39 Message Length

Minimum (0 - 48) *0

C39MIN##

6-6

Maximum (0 - 48) *48

C39MAX##

6-6

Code 39 Append

*Off

C39APP0

6-7

6-6 6-6

On

C39APP1

6-7

Code 32 Pharmaceutical (PARAF)

*Off

C39B320

6-7

On

C39B321

6-7

Code 39 Full ASCII

*Off

C39ASC0

6-8

On

C39ASC1

6-8

Code 39 Code Page

C39DCP

6-9

Interleaved 2 of 5

Default All Interleaved 2 of 5 Settings

I25DFT

Interleaved 2 of 5

Off

I25ENA0

6-9

*On

I25ENA1

6-9

*No Check Char.

I25CK20

6-10

Validate, But Don’t Transmit

I25CK21

Interleaved 2 of 5 Check Digit

6-9

6-10

Validate, and Transmit

I25CK22

6-10

Interleaved 2 of 5 Message Length

Minimum (2 - 80) *4

I25MIN##

6-10

Maximum (2 - 80) *80

I25MAX##

6-10

Code 93

Default All Code 93 Settings

C93DFT

11 - 8

6-11

Page 147

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

Off

C93ENA0

6-11

*On

C93ENA1

6-12

Minimum (0 - 80) *0

C93MIN##

6-11

Maximum (0 - 80) *80

C93MAX##

6-11

Code 93 Code Page

C93DCP

6-11

Straight 2 of 5 Industrial

Default All Straight 2 of 5 Industrial Settings

R25DFT

Straight 2 of 5 Industrial

*Off

R25ENA0

6-12

On

R25ENA1

6-12

Straight 2 of 5 Industrial Message Length

Minimum (1 - 48) *4

R25MIN##

6-12

Maximum (1 - 48) *48

R25MAX##

6-12

Straight 2 of 5 IATA

Default All Straight 2 of 5 IATA Settings

A25DFT

*Off

A25ENA0

6-13

On

A25ENA1

6-13

Straight 2 of 5 IATA Message Length

Minimum (1 - 48) *4

A25MIN##

6-13

Maximum (1 - 48) *48

A25MAX##

6-13

Matrix 2 of 5

Default All Matrix 2 of 5 Settings

X25DFT

Code 93 Code 93 Message Length

Straight 2 of 5 IATA

Matrix 2 of 5

6-12

6-13

6-14

*Off

X25ENA0

6-14

On

X25ENA1

6-14

Matrix 2 of 5 Message Length

Minimum (1 - 80) *4

X25MIN##

6-14

Maximum (1 - 80) *80

X25MAX##

6-14

Code 11

Default All Code 11 Settings

C11DFT

Code 11

*Off

C11ENA0

6-15

On

C11ENA1

6-15

1 Check Digit

C11CK20

6-15

*2 Check Digits

C11CK21

6-15

Code 11 Check Digits Required

6-14

11 - 9

Page 148

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

Code 11 Message Length

Minimum (1 - 80) *4

C11MIN##

6-15

Maximum (1 - 80) *80

C11MAX##

6-15

Code 128

Default All Code 128 Settings

128DFT

Code 128

Off

128ENA0

6-16

*On

128ENA1

6-16

ISBT Concatenation

*Off

ISBENA0

6-16

6-16

On

ISBENA1

6-16

Code 128 Message Length

Minimum (0 - 80) *0

128MIN##

6-17

Maximum (0 - 80) *80

128MAX##

6-17

Code 128 Code Page

Code 128 Code Page (*2)

128DCP##

Telepen

Default All Telepen Settings

TELDFT

Telepen

*Off

TELENA0

6-17

On

TELENA1

6-17

6-17 6-17

*AIM Telepen Output

TELOLD0

6-18

Original Telepen Output

TELOLD1

6-18

Telepen Message Length

Minimum (1 - 60) *1

TELMIN##

6-18

Maximum (1 - 60) *60

TELMAX##

6-18

UPC-A

Default All UPC-A Settings

UPADFT

UPC-A

Off

UPAENA0

6-19

*On

UPAENA1

6-19

Off

UPACKX0

6-19

Telepen Output

UPC-A Check Digit

6-19

*On

UPACKX1

6-19

UPC-A Number System

Off

UPANSX0

6-19

*On

UPANSX1

6-19

UPC-A 2 Digit Addenda

*Off

UPAAD20

6-20

On

UPAAD21

6-20

UPC-A 5 Digit Addenda

*Off

UPAAD50

6-20

On

UPAAD51

6-20

11 - 10

Page 149

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

UPC-A Addenda Required

*Not Required

UPAARQ0

6-20

Required

UPAARQ1

6-20

UPC-A Addenda Separator

Off

UPAADS0

6-20

*On

UPAADS1

6-20

UPC-A/EAN-13 with Extended Coupon Code

*On

CPNENA1

6-21

Off

CPNENA0

6-21

UPC-E0

Default All UPC-E Settings

UPEDFT

UPC-E0

Off

UPEEN00

6-21

*On

UPEEN01

6-21

UPC-E0 Expand

*Off

UPEEXP0

6-21

6-21

On

UPEEXP1

6-21

UPC-E0 Addenda Required

Required

UPEARQ1

6-22

*Not Required

UPEARQ0

6-22

UPC-E0 Addenda Separator

*On

UPEADS1

6-22

Off

UPEADS0

6-22

UPC-E0 Check Digit

Off

UPECKX0

6-22

*On

UPECKX1

6-22

UPC-E0 Number System

Off

UPENSX0

6-23

*On

UPENSX1

6-23

UPC-E0 Addenda

2 Digit Addenda On

UPEAD21

6-23

*2 Digit Addenda Off

UPEAD20

6-23

5 Digit Addenda On

UPEAD51

6-23

UPC-E1 EAN/JAN-13 EAN/JAN-13

*5 Digit Addenda Off

UPEAD50

6-23

*Off

UPEEN10

6-23

On

UPEEN11

6-23

Default All EAN/ JAN Settings

E13DFT

Off

E13ENA0

6-24

*On

E13ENA1

6-24

6-24

11 - 11

Page 150

Selection

Setting

Serial Command

Page

* Indicates default

# Indicates a numeric entry

EAN/JAN-13 Check Digit

Off

E13CKX0

6-24

*On

E13CKX1

6-24

EAN/JAN-13 2 Digit Addenda

2 Digit Addenda On

E13AD21

6-25

*2 Digit Addenda Off

E13AD20

6-25

5 Digit Addenda On

E13AD51

6-25

*5 Digit Addenda Off

E13AD50

6-25

EAN/JAN-13 Addenda Required

*Not Required

E13ARQ0

6-25

Required

E13ARQ1

6-25

EAN/JAN-13 Addenda Separator

Off

E13ADS0

6-25

*On

E13ADS1

6-25

ISBN Translate

*Off

E13ISB0

6-26

On

E13ISB1

6-26

EAN/JAN-8

Default All EAN/ JAN 8 Settings

EA8DFT

EAN/JAN-8

Off

EA8ENA0

6-26

6-26

*On

EA8ENA1

6-26

EAN/JAN-8 Check Digit

Off

EA8CKX0

6-26

*On

EA8CKX1

6-26

EAN/JAN-8 Addenda

*2 Digit Addenda Off

EA8AD20

6-27

2 Digit Addenda On

EA8AD21

6-27

*5 Digit Addenda Off

EA8AD50

6-27

5 Digit Addenda On

EA8AD51

6-27

EAN/JAN-8 Addenda Required

*Not Required

EA8ARQ0

6-27

Required

EA8ARQ1

6-27

EAN/JAN-8 Addenda Separator

Off

EA8ADS0

6-27

*On

EA8ADS1

6-27

MSI

Default All MSI Settings

MSIDFT

6-28

MSI

*Off

MSIENA0

6-28

On

MSIENA1

6-28

11 - 12