Page 131

Supported Interface Keys

ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F

Esprit 200, 400 ANSI Supported Keys Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Esprit 200, 400 ASCII Supported Keys Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab N/A New Line N/A Escape F11 Insert F13 Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

Esprit 200, 400 PC Supported Keys Reserved New Line N/A N/A N/A N/A N/A New Line N/A Tab N/A Tab Delete New Line Insert Escape F11 Home Print Back Space Back Tab F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10

9-5

Page 132

Supported Interface Keys ASCII NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US DEL

9-6

HEX 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F 7F

Apple Mac/iMac Supported Keys Reserved Enter/Numpad Enter CAPS ALT make ALT break CNTRL make CNTRL break RETURN APPLE make TAB APPLE break TAB Del RETURN Ins Help ESC F11 Home Prnt Scrn BACKSPACE LSHIFT TAB F12 F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 BACKSPACE

Page 133

10

Utilities

To Add a Test Code I.D. Prefix to All Symbologies This selection allows you to turn on transmission of a Code I.D. before the decoded symbology. (See the Symbology Chart, included in the Appendix A, page A-1) for the single character code that identifies each symbology.) This action first clears all current prefixes, then programs a Code I.D. prefix for all symbologies. This is a temporary setting that will be removed when the unit is power cycled.

Add Code I.D. Prefix to All Symbologies (Temporary)

Show Decoder Revision Scan the bar code below to output the decoder revision.

Note: You may use the Show Decoder Revision option if you have firmware with a base number of 31205480. Refer to Show Software Revision on page 10-2 for information on determining the firmware revision in your unit.

Show Decoder Revision

Show Engine Revision Note: You may use the Show Engine Revision option if you have firmware with a base number of 31205480. Scan the bar code below to output the engine revision. If your imager has an 4X00 engine, it will return an [ACK] with no data in the string. If your imager has an 5X00 engine, it will return the engine type, revision number, and status character [ACK]. For example, an imager with an 5100, version 26 would return: ENGREVType:

1

Revision: 26[ACK]

Show Engine Revision

10 - 1

Page 134

Show Scan Driver Revision Scan the bar code below to output the scan driver revision. The scan driver controls image capture.

You may use the Show Scan Driver Revision option if you have firmware with a base number of 31205480. Refer to the Show Software Revision below for information on determining the firmware revision in your unit.

Show Scan Driver Revision

Show Software Revision Scan the bar code below to output the current software revision, unit serial number, and other product information.

Show Software Revision

Show Data Format Scan the bar code below to show current data format settings.

Data Format Settings

Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the standard product default settings restored, scan the Standard Product Default Settings bar code below.

Standard Product Default Settings The Menu Commands starting on page 11-4 lists the standard product default settings for each of the commands (indicated by an asterisk (*) on the programming pages).

10 - 2

Page 135

Test Menu When you scan the Test Menu On code, then scan a programming code in this manual, the imager displays the content of a programming code. The programming function will still occur, but in addition, the content of that programming code is output to the terminal.

Note: This feature should not be used during normal imager operation.

On

* Off

2D PQA (Print Quality Assessment) Two-dimensional Print Quality Assessment (2D PQA) is a feature of Honeywell image readers where the data from the successful read of a 2D bar code symbol is augmented with lines of text that both identify the symbol, and also report graded measurement parameters obtained from it.

2D PQA Reporting Honeywell 2D PQA reporting can be enabled in two different modes: Full Report or Screening. (To see displayed results, Microsoft® Notepad or a word processor/editing program is recommended.) If you are using Visual Xpress, you can enable Full Report, a listing of all of a symbol's identifying information, measurements, and corresponding grades, by typing the following menu command: 2D_PQA1 or by scanning the following bar code:

Full Report

Note: The PQA report is sent out as a second data/beep sequence after the bar code data. The report has its own Honeywell code ID of >(0X3E) so it can be uniquely identified.

10 - 3

Page 136

You can exit Full Report mode by either typing the menu command, 2D_PQA0, if you are using Visual Xpress, or by scanning the following bar code:

Exit

Note: For additional information on interpreting your read results, refer to Honeywell Quick Check 2D Print Assessment User’s Guide.

Visual Xpress™ Introduction Visual Xpress provides a wide range of PC-based programming functions that can be performed on an imager connected to your PC's COM port. Visual Xpress allows you to download upgrades to the imager's firmware, change programmed parameters, and create and print programming bar codes. Using Visual Xpress, you can even save/open the programming parameters for an imager. This saved file can be e-mailed or, if required, you can create a single bar code that contains all the customized programming parameters and mail or fax that bar code to any location. Users in other locations can scan the bar code to load in the customized programming. To communicate with an imager, Visual Xpress requires that the PC have a serial port emulation using a physical USB port.

Visual Xpress Operations The Visual Xpress software performs the following operations:

Scan Data Scan Data allows you to scan bar codes and display the bar code data in a window. Scan Data lets you send serial commands to the imager and receive imager response that can be seen in the Scan Data window. The data displayed in the Scan Data window can either be saved in a file or printed.

Configure Configure displays the programming and configuration data of the imager. The imager's programming and configuration data is grouped into different categories. Each category is displayed as a tree item under the "Configure" tree node in the application explorer. When one of these tree nodes is clicked, the right-hand side is loaded with the parameters' form belonging to that particular category. The "Configure" tree option has all the programming and configuration parameters specified for an imager. You can set or modify these parameters as required. You can later write the modified settings to the imager, or save them to a dcf file.

10 - 4

Page 137

Imaging Imaging provides all the image-related functions that a 2D Imager can perform. You can capture an image using the current settings, and the image will be displayed in an image window. Images captured from the imager can be saved to files in different image formats. You can modify the image settings and save the image settings to an INI file, which can be loaded later to capture new images. Imaging also lets you preview the images continuously captured by the imager.

Installing Visual Xpress from the Web Note: Visual Xpress requires .NET software. If .NET is not installed on your PC, you will be prompted to install it during the Visual Xpress installation. 1. Access the Honeywell web site at www.honeywellaidc.com. 2. Click on Downloads. 3. Click on Software. 4. Select your model number from the list of product numbers. 5. Click on the entry for Visual Xpress. 6. When prompted, select Save File, and save the files to the c:\windows\temp directory. 7. Once you have finished downloading the file, exit the web site. 8. Using Explorer, go to the c:\windows\temp file and unzip the file you saved. 9. Double click on Setup.exe and follow the screen prompts to install the Visual Xpress program. 10. If you’ve selected the defaults during installation, you can click on Start Menu-Programs-Honeywell-Visual Xpress.

Temporary USB Com Port Configuration For a quick download communication configuration, scan the Visual Xpress bar code and the imager will be temporarily configured for USB Com Port Emulation.

USB Com Port Emulation (temporary)

10 - 5

Page 138

10 - 6

Page 139

11

Serial Programming Commands

The serial programming commands can be used in place of the programming bar codes. Both the serial commands and the programming bar codes will program your imager. For complete descriptions and examples of each serial programming command, refer to the corresponding programming bar code in this manual. The device must be set to an USB Com Port Emulation interface (see page 1-5). The following commands can be sent via a PC COM port using terminal emulation software.

Conventions The following conventions are used for menu and query command descriptions:

parameterA label representing the actual value you should send as part of a command. [option] An optional part of a command. {Data} Alternatives in a command. bold Names of menus, menu commands, buttons, dialog boxes, and windows that appear on the screen.

Menu Command Syntax Menu commands have the following syntax (spaces have been used for clarity only):

Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage Prefix

Three ASCII characters: SYN M CR (ASCII 22,77,13).

Tag

A 3 character case-insensitive field that identifies the desired menu command group. For example, all beeper configuration settings are identified with a Tag of BEP.

SubTag

A 3 character case-insensitive field that identifies the desired menu command within the tag group. For example, the SubTag for the Beeper Volume is LVL.

Data

The new value for a menu setting, identified by the Tag and SubTag.

Storage

A single character that specifies the storage table to which the command is applied. An exclamation point (!) performs the command’s operation on the device’s volatile menu configuration table. A period (.) performs the command’s operation on the device’s non-volatile menu configuration table. Use the non-volatile table only for semi-permanent changes you want saved through a power cycle.

11 - 1

Page 140

Query Commands Several special characters can be used to query the device about its settings.

^ ? *

What is the default value for the setting(s). What is the device’s current value for the setting(s). What is the range of possible values for the setting(s). (The device’s response uses a dash (-) to indicate a continuous range of values. A pipe (|) separates items in a list of non-continuous values.)

Tag Field Usage When a query is used in place of a Tag field, the query applies to the entire set of commands available for the particular storage table indicated by the Storage field of the command. In this case, the SubTag and Data fields should not be used because they are ignored by the device. SubTag Field Usage When a query is used in place of a SubTag field, the query applies only to the subset of commands available that match the Tag field. In this case, the Data field should not be used because it is ignored by the device. Data Field Usage When a query is used in place of the Data field, the query applies only to the specific command identified by the Tag and SubTag fields.

Concatenation of Multiple Commands Multiple commands can be issued within one Prefix/Storage sequence. Only the Tag, SubTag, and Data fields must be repeated for each command in the sequence. If additional commands are to be applied to the same Tag, then the new command sequence is separated with a comma (,) and only the SubTag and Data fields of the additional command are issued. If the additional command requires a different Tag field, the command is separated from previous commands by a semicolon (;).

Responses The device responds to serial commands with one of three responses: ACK Indicates a good command which has been processed. ENQ Indicates an invalid Tag or SubTag command. NAK Indicates the command was good, but the Data field entry was out of the allowable range for this Tag and SubTag combination, e.g., an entry for a minimum message length of 100 when the field will only accept 2 characters. When responding, the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks (the period, exclamation point, comma, or semicolon) in the command.

11 - 2