fi-5000N Operator's Guide: Chapter 5 Installing and setting the fi-5000N Software, pages 55 to 64

Pages 55 to 64 of 118, from fi-5000N Operator's Guide

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Fujitsu fi-5000N

Page 55

Chapter 5 Installing and setting the fi-5000N Software To control a fi-5000N connected to the network from your PC, and to scan with the scanner connected to the fi-5000N, install the "fi-5000N Software" on: • The PC of fi-5000N’s Administrator • The PCs used by the scanner’s users This chapter describes the installation and operation procedures of the fi-5000N Software.

5 5.1 Installing fi-5000N Software.............................................................................42

5.2 fi-5000N Software Overview.............................................................................44

5.3 Adding and Deleting fi-5000N..........................................................................48

5.4 Managing User Information of fi-5000N..........................................................51

5.5 fi-5000N Administrator Settings ......................................................................56

5.6 Managing Scanner Information .......................................................................59

5.7 Settings of [Launch Options] ..........................................................................64

5.8 Uninstalling the fi-5000N Software..................................................................67 fi-5000N Operator’s Guide

41

Page 56

5.1

Installing fi-5000N Software

■ Preparation Before starting the installation, check the following contents. • Prepare the Setup CD-ROM

■ System Requirements The system requirements for the fi-5000N is as follow. • Operating System Microsoft Windows 98 Microsoft Windows 2000 Professional Microsoft Windows Millennium Edition Microsoft Windows XP Professional Microsoft Windows XP Home Edition

• RAM 128 MB or higher

■ Installing Windows XP screenshots are used in this section as examples. The windows and operations may slightly vary depending on your OS.

HINT

1. Turn on the power of the PC, and log on to Windows.

ATTENTION

When using Windows 2000 or Windows XP, log on as a user with "Administrator" rights.

2. Insert the Setup CD-ROM into the CD drive.

⇒ <SETUP DISK START UP SCREEN> appears.

ATTENTION

42

This screen may not appear when the "Autoplay" setting of your PC is OFF. In this case, run "Install.exe" in this CD-ROM directly from the "Explorer" or "My Computer".

Page 57

5.1 Installing fi-5000N Software 3. Click [INSTALL PRODUCTS].

4. Click [fi-5000N Software] on the window below.

5

6. Follow the instructions on the window to install the application. 7. When the [InstallShield Wizard Complete] window appears, click [Finish]. Installation of the fi-5000N Software is completed.

fi-5000N Operator’s Guide

43

Installing and setting the fi-5000N Software

5. Select a language used for installation on [Choose Setup Language] window and click [OK].

Page 58

5.2 fi-5000N Software Overview

■ Starting fi-5000N Configuration Tool To start the fi-5000N software, from the [Start] menu, select [All Programs] -> [fi-5000N Software] -> [fi-5000N Configuration Tool].

ATTENTION

If Windows XP Service Pack 2 is installed, [Windows Security Alert] dialog box may appear when starting up fi-5000N Software. If [Keep Blocking] is selected with Windows firewall, PC cannot communicate with fi-5000N. In this case, click [Unblock] to start the program.

■ [Select Scanner] Tab (Main Screen) This screen (in which the [Select Scanner] tab is selected) is the main screen. All kinds of administrative settings of fi-5000N can be done from this screen.

Tabs Buttons

List View The fi-5000Ns connected to the network are displayed in a list.

44

Page 59

5.2 fi-5000N Software Overview

Name of Item

Function

[OK] button

Closes the screen and exits the fi-5000N Configuration Tool.

[Refresh] button

Updates and displays the latest information of the List View.

[Favorite] button

Selects a scanner to use among the scanners connected to the network. With the device name selected, when you click this button, a "*" is displayed in the "Favorite" column, and it is configured as the default scanner. When using multiple scanners, this button helps you to switch easily to other scanners.

[Add] button

Adds a new fi-5000N to the List View. There is no need to add because the fi-5000N in the same subnet as the PC is displayed automatically in the list. To add an fi-5000N which is in other subnet, use this button.

[Delete] button

Deletes the selected fi-5000N from the list. (An fi-5000N cannot be deleted if it is in the same subnet as your PC.)

[User Config.] button

Registers/changes/deletes user information of the selected fi5000N. Can be used only by the Operating Administrator. The Administrator PIN is necessary.

[Admin.] button

Changes the name of the selected fi-5000N, network settings, and Administrator PIN. Also, user information can be backed up and restored. Can be used only by the Administrator. The Administrator PIN is necessary.

[Scanner Info.] button

Displays the information of the scanner that is connected to fi5000N. (It can be used by both, Administrator and users) Consumables counters resetting, offset settings and power saving settings can also be done. (Only by the Administrator)

45

Installing and setting the fi-5000N Software fi-5000N Operator’s Guide

5

Page 60

■ [Launch Option] Tab The scanning application to be started when the button on the scanner ([Scan] or [Send To]) is pressed, can be configured from this screen.

Name of Item

46

Function

Button:

Selects the button to be configured from among "Scan", and "Send To 1 - Send To 9". You must set the following "Target", "Argument" and "Start In", otherwise no application will start up.

Target:

Specifies the file name of the application to be started.

Argument:

Configures the argument to be passed to the specified application that is started. With this function, you can also add more actions than just start the scanning application when scanner button is pressed. The argument that can be specified differs depending on the application being used. (Refer to "5.7 Settings of [Launch Options]" (page 64) for details.)

Start In:

Specifies the default folder when the application starts.

Page 61

5.2 fi-5000N Software Overview

■ [Advance] Tab When receiving image data, the trigger port number for the fi-5000N, may conflict with other applications. This setting is used to change the trigger port number on the PC.

Name of Item

Function

Trigger port (PC):

Used to specify a trigger port number on the PC.

[Default] button:

Resets to the default number.

Installing and setting the fi-5000N Software

ATTENTION

5

When changing the trigger port number on the PC, you must also change the trigger port on the fi-5000N. Refer to "5.5 fi-5000N Administrator Settings" (page 56). If the both port numbers are not the same, the fi-5000N will not work correctly.

■ [Version] Tab This tab shows the version information of the fi-5000N Configuration Tool.

fi-5000N Operator’s Guide

47

Page 62

5.3

Adding and Deleting fi-5000N When a fi-5000N is in the same subnet as the PC, it is automatically recognized and displayed in the List View. However, when it is in other subnet, add or delete with the following procedure.

■ Adding fi-5000N 1. Click the [Add] button on the main screen of fi-5000N Configuration Tool.

2. Specify the IP address or host name of the fi-5000N to be added.

Select either the "IP Address:" or "Host Name", and enter the necessary information. Example of entry: IP Address: 192.168.1.100 Host name: fi-5000n-00-01.fi-domain.xx.jp

48

Page 63

5.3 Adding and Deleting fi-5000N

ATTENTION

Certain DNS servers and DHCP servers, which do not support DNS update, may cause host name resolution problems when DHCP is specified in IP address settings with fi-5000N. If you experience such problems, consult with your network administrator and take one of the following measures for fi-5000N and PC: For fi-5000N, 1) Change to DNS server and DHCP server which support DNS update. 2) Set the IP address lease time longer in DHCP server settings. 3) Use static IP method. For PC, 1) Change to DNS server and DHCP server which support DNS update. 2) Set the IP address lease time longer in DHCP server settings and register the PC name on the DNS server. 3) Use static IP method.

3. Click the [OK] button.

HINT

5

There is no need to add it manually as it is automatically detected if it is on the subnet.

Installing and setting the fi-5000N Software fi-5000N Operator’s Guide

49

Page 64

■ Deleting fi-5000N 1. Select the fi-5000N you want to delete from the List View of the main screen of fi5000N Configuration Tool.

2. Click the [Delete] button. 3. Click [Yes] when the confirmation message appears.

HINT

50