Infrared Data Transfer Is Not Working

If you are experiencing problems transferring data over the system’s infrared interface, note the following:

Can the IrDA port on the pen tablet “see” the IrDA port on the other device? A direct line-of-sight path must exist between the IrDA port on the pen tablet and the IrDA port on the other device.

The distance between the two devices must not be more than approximately 3 feet or 1 meter.

The viewing angle from the IrDA port on the pen tablet must not be more than 15 degrees from a center line between the IrDA port on the pen tablet and the IrDA port on the other device.

The device with which you are trying to communicate must be compliant with the IrDA Standard Revision 1.1 (or 1.0).

Pen Tablet ls Not Responding to the Pen

If your pen tablet is not responding to the pen, connect an external keyboard to the system to see if it responds to keyboard commands. If the system doesn’t respond to the keyboard, the application or system may have crashed, and it may be necessary to reset the system.

Audio Volume Too Low

If the audio volume on your pen tablet speaker or external headphones is too low, check the following:

Ensure that the speaker (or headphone output if using headphones) is enabled. To do so, tap the Speaker Mute hotpad. The system beeps when the speaker or headphone output is turned on using the hotpad.

Ensure that the volume level set with the Volume hotpads is set to an audible level.

Ensure that the mute box in the system volume control (accessible from the system tray) is not set.

Ensure that any volume control in your audio software is set to an audible level.

Troubleshooting 35

Page 42 read from a scan by OCR; it may hold reading errors

Configuring Peripherals Interfaces

Certain peripheral devices can be disabled during the BIOS Setup. If the peripheral interface you want to use does not appear to be working with your peripheral device, ensure that it is enabled in the BIOS. Contact your local help desk or reseller if you need assistance using BIOS Setup.

36 Care and Maintenance

Page 43 read from a scan by OCR; it may hold reading errors

Appendix A

Agency Notices

UL Notices

Cautions

* For continued protection against the risk of fire, replace only with the same type and rating of fuse.

* There is a danger of explosion if the CMOS battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to manufacturer's instruction.

* Changes or modifications not expressly approved by Fujitsu PC Corp. could void this user’s authority to operate the equipment.

Warnings

* The CMOS battery may explode if mistreated. Do not recharge, disassemble, or dispose of in fire.

* For a spare battery pack, order only Fujitsu Model FMW42BP1.

* To charge the battery pack FMW42BP1 externally, use only a Stylistic external battery charger model FMW42BC1.

FCC Notices

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules.

Changes or modifications not expressly approved by Fujitsu PC Corporation, could void the user’s authority to operate the equipment.

Notice to Users of Radios and Television

These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which

Agency Notices 37

Page 44 read from a scan by OCR; it may hold reading errors

can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

* Reorient or relocate the receiving antenna.

¢ Increase the separation between the equipment and receiver.

¢ Connect the equipment into an outlet that is on a different circuit than the receiver.

* Consult the dealer or an experienced radio/TV technician for help.

Shielded interconnect cables must be employed with this equipment to ensure compliance with the pertinent RF emissions limits governing this device.

Notice to Users of the US Telephone Network

38

The Stylistic 3400 pen tablet is supplied with an internal modem which complies with Part 68 of the FCC rules. On the pen tablet is a label that contains the FCC Registration Number and Ringer Equivalence Number (REN) of this system, along with other information. If requested, users must provide their telephone company with the following information:

¢ The telephone number to which the pen tablet is connected ¢ The Ringer Equivalence Number (REN) for this equipment

¢ The information that the system requires a standard modular jack type USOC RJ-11C which is FCC Part 68-compliant

¢ The FCC Registration Number

This equipment is designed to be connected to the telephone network or premises wiring using a standard modular jack type USOC RJ-11C which is FCC Part 68-compliant.

The REN is used to determine the number of devices you may connect to your telephone line and still have all those devices ring when your number is called.Too many devices on one line may result in failure to ring in response to an incoming call. In most, but not all, areas, the sum of all of the devices should not exceed five (5). To be certain of the number of devices you may connect to your line, as determined by the RENs, contact your local telephone company.

If this equipment causes harm to the telephone network, your telephone company may discontinue your service temporarily. If possible, they will notify you in advance. If advance notice is not practical, they will notify you as soon as possible. You will also be advised of your right to file a complaint with the FCC.

Appendix

Page 45 read from a scan by OCR; it may hold reading errors

This fax modem also complies with fax branding requirements per FCC Part 68.

If you experience trouble with this equipment, please contact your support representative.

Your telephone company will probably ask you to disconnect this equipment from the telephone network until the problem is corrected and you are sure that the equipment is not malfunctioning.

This equipment may not be used on coin service telephones provided by your telephone company. Connection to party lines is subject to state tariffs. Contact your state’s public utility commission, public services commission, or corporation commission for more information.

FCC rules prohibit the use of non-hearing aid compatible telephones in the following locations or applications: ¢ All public or semipublic coin-operated or credit card telephones.

¢ Elevators, highways, tunnels, (automobile, subway, railroad, or pedestrian) where a person with impaired hearing might be isolated in an emergency.

¢ Places where telephones are specifically installed to alert emergency authorities such as fire, police, or medical assistance personnel.

¢ Hospital rooms, residential health care facilities, convalescent homes, and prisons. ¢ Workstations for the hearing impaired.

¢ Hotel, motel, or apartment lobbies.

* Stores where telephones are used by patrons to order merchandise.

¢ Public transportation terminals where telephones are used to call taxis or to reserve lodging or rental cars.

* In hotel and motel rooms at least ten percent of the rooms must contain hearing aid compatible telephones which will be provided to hearing impaired customers on request.

DOC (Industry Canada) Compliance Notices This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set forth in the radio interference regulations of the

Canadian Department of Communications.

Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de classe B prescrites dans le reglement

Agency Notices 39

Page 46 read from a scan by OCR; it may hold reading errors

sur le brouillage radioélectrique édicté par le Ministére des Communications du Canada.

Notice to Users of Radios and Television

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du réglement sur le matériel brouilleur du Canada.

Notice to Users of the Canadian Telephone Network

40

The Canadian Industry Canada label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational, and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction.

Repairs to telecommunication equipment should be made by a Canadian authorized maintenance facility. Any repairs or alterations not expressly approved by Fujitsu PC Corp. or any equipment failures may give the telecommunications company cause to request the user to disconnect the equipment from the telephone line.

The connecting arrangement code for this equipment is CA11A. The Load Number is 0.2.

The Load Number assigned to each telephone terminal device denotes the percentage of the total load to be connected to a telephone loop or circuit to be used by the device to prevent overloading. The termination on a loop may consist of any combination of devices such that the total of the load numbers of all devices does not exceed 100.

Caution

For safety, users should ensure that the electrical ground of the power utility, the telephone lines, and the metallic water pipes are connected together. Users should not attempt to make such connections themselves but should contact the appropriate electric inspection authority or electrician. This may be particularly important in rural areas.

Appendix

Page 47 read from a scan by OCR; it may hold reading errors

Avis Aux Utilisateurs Du Réseau Telephonique Canadien

L’étiquette canadienne Industrie Canada identifie l’équipement certifié. Cette certification signifie que l’équipement satisfait certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le département ne garantit pas le fonctionnement de l’équipement 4 la satisfaction de l'utilisateur.

Le Stylistic 3400 possede un modem interne conforme aux normes de certification d’Industrie Canada pour protéger les réseaux de télécommunications et satisfaire aux normes de sécurité. Avant de connecter cet équipement a une ligne téléphonique, l'utilisateur doit vérifier s’il est permis de connecter cet équipement aux installations de télécommunications locales. L’utilisateur est averti que méme la conformité aux normes de certification ne peut dans certains cas empécher la dégradation du service.

Les réparations de l’équipement de télécommunications doivent étre effectuées par un service de maintenance agréé au Canada. Toute réparation ou modification, qui nest pas expressement approuvée par Fujitsu PC Corp., ou toute défaillance de l’équipement peut entrainer la compagnie de téléecommunications a exiger que l'utlilisateur déconnecte l’équipement de la ligne téléphonique.

Le code d’arrangement de connexion de cet équipement est CA11A. Le numéro de charge est 0.2.

Le numéro de charge assigné a chaque terminal téléphonique indique le pourcentage de la charge totale pouvant étre connecté a une boucle ou a un circuit téléphonique, utilisé par ce périphérique afin de prévenir toute surcharge. La terminaison d’une boucle peut étre constituée de n’importe quelle combinaison de périphériques de sorte que le total de numéros de charge de tous les périphériques n’excéde pas 100.

Avertissement

Pour assurer la sécurité, les utilisateurs doivent vérifier que la prise de terre du service d’électricité, les lignes téléphoniques et les conduites d’eau métalliques sont connectées ensemble. Les utilisateurs NE doivent PAS tenter d’établir ces connexions eux-mémes, mais doivent contacter les services d’inspection d’installations électriques appropriés ou un électricien. Ceci peut étre particuliérement important en régions rurales.

Agency Notices 41

Page 48 read from a scan by OCR; it may hold reading errors

42

Appendix

Page 49 read from a scan by OCR; it may hold reading errors

Appendix B

Stylistic 3400 Hardware Specifications

The following table provides general hardware specifications of the Stylistic 3400 by category. Stylistic 3400 Specifications Physical Specifications Dimensions 11” w x 8.5" d x 1.1” h (280mm x 215mm x 27.4mm) Weight 3.2 Ibs. (1.45 Kg) Processing Specifications CPU Intel Pentium III Chip set Intel 440MX - 100 Processor Speed 400 MHz Memory/Storage Specifications Main RAM 64 MB on main board 32MB, 64MB, and 128MB expansion modules available, with a system maximum of 192 MB. L1 cache (CPU) 16 KB L2 cache 256 KB BIOS ROM 512 KB (flash ROM upgradeable) Hard disk drive * Removable 2.5” HDD * 6 GB IDE HDD ¢ Ultra DMA

Stylistic 3400 Hardware Specifications

43

Page 50 read from a scan by OCR; it may hold reading errors

Stylistic 3400 Specifications (Continued)

Input/Output Specifications

Digitizer

¢ Resistive, with palm rejection

Display

* Indoor Color Display 10.4” TFT XGA (1024 x 768 dot) 256K colors Brightness: 8 levels

¢ Indoor/Outdoor Color Display 10.4” TFT SVGA (800 x 600 dot) 256K colors Brightness: 8 levels

VRAM

2.5 MB VRAM

Interface Specifications

PC Card Slots

* One Type-ll ¢ PCMCIA CardBus version 3.0 * Zoom Video port

Integrated Interfaces

* FDD

* RJ-11

* USB

* DC-In

* Video connector

* Expansion connector

Infrared

IrDA version 1.1 (FIR, 4Mbps)

Audio

* Sound Function + AC’97 codec (18-bit stereo codec) ¢ Sound Blaster Pro-compatible ¢ Internal microphone and speaker

¢ Microphone and headphone jacks

High-Usage Docking Contacts

¢ DC-In ¢ USB Host

44 Appendix