Page 61

FST 200

3. Management of the control programs

Part 2 of this list shows those symbolic operands which were not found in the allocation lists, i.e. do not yet have an absolute operand. This allows you a check on which information must still be entered. Otherwise, your control program will not be executable.

Fig. 3.9: Printing the cross-reference list 3.6.6 Print error list When this function is selected, the current error list is printed on the connected printer. These error messages are listed in Appendix C.3.

9610a

3-15

Page 62

FST 200

3.7

3. Management of the control programs

Load project Use this function, when • You wish to load a complete project with all its program parts into the controller, • You wish to load several program parts from a project into the controller at the same time. Start these routines by opening the Load project function from the Project management menu. All the program parts within the current project will then be listed (see Fig. 3.10).

Fig. 3.10: Loading a project Before loading a project into a controller, you must make certain that the connection between the controller and your computer has been established correctly (see section 6.1)

3-16

9610a

Page 63

FST 200

3. Management of the control programs

You can now select from the programs listed the program you wish to load into the controller by clicking on it or placing the highlight over it and pressing the ENTER key. Programs selected in this way are marked with an asterisk at the start of the line. Then select function F1. The programs selected are now translated into the machine code. This routine includes a syntax test; any irregularities will be entered in the error list. The loading process then follows. A "Loading program" message window shows all the files transferred one by one with their sizes. If the message

FPC connection could not be established appears in the message line before loading, you should check that the controller is correctly connected and switched on (see 2.2).

9610a

3-17

Page 64

FST 200

3.8

3. Management of the control programs

Backup/Restore (Project Backup) This function assists you in file handling for complete projects. You can: • Backup a project to an external storage device • Restore a project from external storage • Rename a project in full • Delete a project completely • Format disks. Calling Project Backup Open this function through project management. Here you should select the Back up Project function. A window opens to allow selection of the various functions (see Fig. 3.11).

Fig. 3.11: Project backup

3-18

9610a

Page 65

FST 200

3. Management of the control programs

Open the function required by clicking on it with the mouse or select the function with the cursor keys and press the ENTER key.

The default target drive is drive A. You must first enter a new drive designation if you wish to use the Project Backup functions on another target drive (see below). 3.8.1 Description of the functions This section explains the functions in the same sequence as they are shown in Fig. 3.11. Back up project This function is used to backup all the files of a project to the target drive you have specified. A project selection window is displayed when this function is opened (see Fig. 3.12).

9610a

3-19

Page 66

FST 200

3. Management of the control programs

Fig. 3.12: Project selection, backup project Select the project required by clicking on it or by placing the highlight on it and pressing the ENTER key. A further window appears with the prompt:

yes

The message line shows: "Project <Name> - please wait" and the copying procedure begins.

no

The program returns to the status shown in Fig 3.11.

Project will be backed up to drive A: (Y/N)

3-20

9610a

Page 67

FST 200

3. Management of the control programs

Restore project Use this option to restore a project already saved to the external storage device to the hard disk. When you open this function, you first see the selection window similar to that in Fig. 3.12. Here you can select the project to be restored by clicking on it or by selecting it with the cursor keys and pressing the ENTER key. A further window first appears with the prompt:

Project will be restored to drive C:\FESTO\ (Y/N).

yes no

The message line shows: "Project <Name> - please wait" and the program checks whether a project with this name already exists on the hard disk. The program returns to the status shown in Fig 3.11.

If the project is already on you hard disk, you will be prompted:

Project will be overwritten! (Y/N) . yes no

9610a

The message line then displays the files currently being processed. On completion, the screen shown in Fig. 3.11 is displayed.

The program returns immediately to the status shown in Fig 3.11.

3-21

Page 68

FST 200

3. Management of the control programs

Delete project This function may be used to delete a project stored on the external storage device. The project selection window is first displayed when this function is opened (see Fig. 3.12). Select the relevant project required by clicking on it or by placing the highlight on it and pressing the ENTER key. A window appears with the prompt:

Project will be deleted from drive A: (Y/N). yes no

The message line shows: "Project <Name> - please wait" and the delete procedure begins. Then the screen shown in Fig. 3.11 is displayed. The program returns immediately to the status shown in Fig 3.11.

You can only use this function to delete projects stored on the external storage device.

3-22

9610a

Page 69

FST 200

3. Management of the control programs

Rename project This function may be used to give a new project name to a project stored on the external drive. The project selection window is displayed when this function is opened (see Fig. 3.12). Select the relevant project required by clicking on it or by placing the highlight on it and pressing the ENTER key. You will see the display illustrated in Fig. 3.13.

Fig. 3.13: Renaming a project

9610a

3-23

Page 70

FST 200

3. Management of the control programs

You should now enter the new project name in the small field in the message line (a maximum of eight characters, digits and underline are also permitted) and press the ENTER key. The message line then displays the files currently being renamed. When the procedure has been completed, the function selection menu shown in Fig. 3.11 appears again. Target drive (A:, B:) Use this function to change the identifier for the target drive. When this function is opened, an additional input field appears in the message line as shown in Fig. 3.14.

Fig. 3.14: Changing a target drive

3-24