Page 391

FST 200-STL

Appendix A

Input Operations:

interrogate

I0.0 - I31.7 I0.0.0 - I0.15.7 I1.0.0 - I31.15.7 I1.0.0 - I31.7.15

One-bit, local inputs (incl. CP, AS-i) One-bit, diagnostics inputs One-bit, field bus inputs (8 bit) One-bit, field bus inputs (16 bit)

Input words Operations:

load, compare

IW0 - IW31 IW0.0 - IW31.15 IW1.0 - IW31.7

Multi-bit-bit, local inputs (incl. CP, AS-i) Multi-bit, diagnostics and field bus inputs (8 bit) Multi-bit, field bus inputs (16 bit)

Output Operations:

interrogate, set, assign

O0.0 - O31.7 O0.0.0 - O0.15.7 O1.0.0 - O31.15.7 O1.0.0 - O31.7.15

One-bit, local outputs (incl. CP, AS-i) One-bit, diagnostics outputs One-bit, field bus outputs (8 bit) One-bit, field bus outputs (16 bit)

Output words Operations:

load, compare, assign

OW0 - OW31 OW0.0 - OW31.15 OW1.0 - OW31.7

9610a

Multi-bit-bit, local outputs (incl. CP, AS-i) Multi-bit, diagnostics and field bus outputs (8 bit) Multi-bit, field bus outputs (16 bit)

A-5

Page 392

FST 200-STL

Appendix A

Timer Operations:

One-bit: interrogate, start, stop Multi-bit: load, compare

T0 to T31 TW0 to TW31 TP0 to TP31

Timer status, pulse timer, one-bit Timer word, multi-bit Timer preselection, multi-bit Preselection value:

0.00 to 655.35s

Counter Operations:

one-bit: interrogate, set, reset Multi-bit: load, compare, assign

C0 to C31 CW0 to CW31 CP0 to CP31

Counter status, one-bit Counter word, multi-bit Counter preselection, multi-bit Preselection value: decimal +/-: -32768 to +32767 decimal +: 0 to 65535 hexadecimal: $0000 to $FFFF

Constant Operations: Vnnnnn load, compare Multi-bit Range of values: decimal +/-: -32768 to +32767 decimal +: 0 to 65535 hexadecimal: $0000 to $FFFF

A-6

9610a

Page 393

FST 200-STL

Appendix A

Register Operations:

load, compare, assign

R0 to R127

Multi-bit Range of values: decimal +/-: -32768 to +32767 decimal +: 0 to 65535 hexadecimal: $0000 to $FFFF

Function unit Operations:

load, compare, assign

For SF 3 FU0 to FU4095

Special function unit Module parameters

Program Operations:

interrogate, set, load

P0 to P15

One-bit

Error Operations:

interrogate, delete

E EW

One-bit Multi-bit

Index register Operations: load, compare, assign for indexed addressing x, y

9610a

Multi-bit

A-7

Page 394

FST 200-STL

Appendix A

A.1.3 Syntax Operand

Address key

Iw.b Ow.b Ef.w.b Af.w.b IWw OWw IWf.w OWf.w f= w= b= field bus station no. word number bit number

Fw.b FWw w= b= flag word number bit number

Pp p= program number

Timer preselection The values in the timer preselection are expressed in hundredths of a second e.g.: TP=125 ... timer preselection is 1.25 seconds). You may also enter the timer preselection as real-time e.g.: 123.45s.

A-8

9610a

Page 395

FST 200-STL

A.2

Appendix A

Multitasking operation for programmable valve terminal with control block SF 3 The SF 3 has a multitasking-capable operating system. This permits a number of tasks to be processed simultaneously on the one processor. A task is a single processor cycle; i.e. one step in an STL program. Comment on modules If you call a program or function module instead of a further program, the module takes the place of the next step. The calling program will only be continued at the point of suspension once the module has been completely processed. The multitasking process is described in detail in the SF-3 description "Electronics".

9610a

A-9

Page 396

FST 200-STL

A.3

Appendix A

Syntax of the control program in the statement list The last section in this appendix shows all possible STL statement list diagrams in the sequence appropriate for programming. These are intended to help you as a user of the statement list in your program generation work. Please consult appendix A.1.2 for the range of values of the various operands.

Program of statement list:

Step

End

Statement

Execution part

Step:

Step

A-10

Label

THEN

Execution part

Statement

9610a

Page 397

FST 200-STL

Appendix A

Statement:

IF

Conditional part

THEN

NOP

Execution part NOP

OTHRW

Execution part NOP

Conditional part:

Multi-bit comparison

Bit assignment

EXOR expression

Bit assignment

LOAD AND OR EXOR

9610a

A-11

Page 398

FST 200-STL

Appendix A

EXOR Expression:

One-bit operand

AND OR EXOR

One-bit operand:

Bit operand N NOT

(

EXOR expression

)

Multi-bit comparison

Bit operand:

Operand reference Input (I) Output (O) Flag (F) Counter (C) Timer (T) Error (E) Program (P)

A-12

9610a

Page 399

FST 200-STL

Appendix A

Multi-bit comparison:

Multiple-bit value

< <= = => > <>

Multiple-bit value

Multi-bit value:

Base term * / + AND OR EXOR

Base term:

Word operand (

9610a

Multi-bit value

SI )

A-13

Page 400

FST 200-STL

Appendix A

Execution part:

One-bit expression Multi-bit expression Count command SET

Settable bit operand Program

RESET

Settable bit operand Program Error

Module call PSE JMP TO

A-14

Label

9610a