Page 31

FST 200

2.2

2. Setting up the software

Configuring the FST program The FST software links a number of hardware components (e.g. PC, controller, printer). Entries in the configuration menu ensure that they are configured to work together. Configuration is divided into four stages: • Computer configuration • Controller configuration • Set printer control sequences (including printer selection) • Field bus configuration or AS-i Master configuration, if required (see section 8) You enter the configuration routine, • When you start the FST software for the first time after installation (see section 2.3) and acknowledge the message:

Please configure FST project path <ESC> by pressing the ESC key; • Each time you activate the Configuration function from the utility programs. You are then first taken to the Computer configuration function (see Fig. 2.3). 2.2.1 Computer configuration The computer configuration window appears on the screen after the FST program is started for the first time (see section 2.3) or when you activate the Configuration function (see Fig. 2.3).

9610a

2-5

Page 32

FST 200

2. Setting up the software

Fig. 2.3: PC configuration data You may overwrite the various entries once you have positioned the cursor in the relevant field. Press the INS key and type in the characters (insert mode). Do not forget to press this key again afterwards (overwrite mode). You can delete superfluous characters with the DEL key or with the backspace key (see section 2.5). From here, use the function keys to switch to controller configuration or to the screen for setting the printer control sequences and printer selection. In addition, function key F4 allows you to enter any program call (see section 3.10).

2-6

9610a

Page 33

FST 200

2. Setting up the software

Initialization Here you can enter instructions to be executed immediately after the FST software is started. Such instructions might be: • Any DOS command, e.g. setting the serial interface with the MODE command, • A BATCH file (..... .BAT), but this may not activate a memory-resident program, • Any executable program. Termination: Here you can enter instructions to be executed before the FST software is exited. Such instructions might be: • Any DOS command, e.g. resetting the serial interface with the MODE command, • Any executable programs. • If you work with the memory-resident emulators, it is useful to enter EABG1N -u as these emulators are then uninstalled when you quit FST 200.

9610a

2-7

Page 34

FST 200

2. Setting up the software

Comments on initialization and termination You will need two serial interfaces if you wish to work with a serial mouse. These must be defined as COM1 and COM2. If you use a serial mouse on COM1 or COM2, you must ensure in all your other entries that this interface is excluded for use by other devices. Your serial interface must always be active. If you make a COM1 or COM2 serial interface exclusively available for the connection of the controller, you should enter a DOS command in Initialization such as MODE COM1:9600,N,8,1. If you use the serial interface for the connection of the controller for other tasks whilst you are using the FST software (e.g. connection of a serial printer), you should take this into consideration accordingly in the later controller configuration (see section 2.2.2). Project directory This entry contains the directory path. Here, your control programs are stored in the form of projects. The default is the C:\FESTO directory. You can change this default by overwriting it.

If the project directory specified does not exist on the hard disk, it will be created automatically by the FST software when you leave the configuration routine (see section 2.2.5).

2-8

9610a

Page 35

FST 200

2. Setting up the software

Screen adapter E - Enhanced Graphic Adapter V - Video Graphic Array C - Color Graphic Adapter H - Hercules Graphic Card and compatible M - IBM monochrome card. Monitor type M - Monochrome monitor F - Colour monitor. Mouse type M - Microsoft® mouse and compatibles N - No mouse

If you have inadvertently entered incorrect data during computer configuration, and the screen displays no information once you have completed configuration, you must delete the file KONFIG.FST from the program directory at the DOS level. Do this with the command: DEL KONFIG.FST When you start the FST software again (see section 2.3), you will be taken back into the Computer configuration function.

9610a

2-9

Page 36

FST 200

2. Setting up the software

2.2.2 Controller configuration In the screen shown in Fig. 2.3 enter the controller configuration function by selecting FPC (F5). The following screen image appears when you activate this function (see Fig. 2.4)

Fig. 2.4: Controller configuration data SF 3 interface This parameter specifies the port on the computer to which the controller is connected (COM1 or COM2), and the baud rate at which data transmission is to take place. Check that the controller is connected to the port and is running at the baud rate specified. You can change these defaults by overwriting them.

Section 7.3 describes how to connect your computer to the controller correctly.

2-10

9610a

Page 37

FST 200

2. Setting up the software

If you use the specified port exclusively for connection with the controller, you should make no entries on initialization and termination in the controller configuration shown in Figure 2.4. SF 3 initialization If you wish to use the same serial interface COM1 or COM2 for the controller and for other devices (e.g. a serial printer or an EPROM programmer), you should enter here a DOS command such as MODE COM1:9600,N,8,1

This DOS command initializes the interface for the controller. SF 3 termination If you are connecting the controller and other devices to the same serial interface COM1 or COM2, you should enter here a DOS command ensuring that the interface is configured correctly for the second connected device, such as: MODE COM1:2400,N,8,1.

This command ensures that the transmission characteristics of the interface are always reset on conclusion of the communication with the controller. Note for users of an FPC 202C FST 200 can be used to program all FPC 202C devices. Following installation, FST 200 is initially set to FPC 203/SF3. You may use the function -> FST 202C (F7) in the main menu (similar to that shown in Fig. 2.8) to switch over to the FPC 202C.

9610a

2-11

Page 38

FST 200

2. Setting up the software

2.2.3 Selecting the printer type You may use the Printer selection (F1) function to select which printer you wish to use for printing, or to divert the print output to a file. When the function is activated, a window listing the printer types supported by the FST software appears on the screen.

Fig. 2.5: Printer selection

Select the User specific option if the printer you wish to use is not included in the list of options. Then enter the control sequences your printer uses. The control sequences for the EPSON FX 80/81 are entered as the default value. Once you have selected a printer type, the control sequences for that printer are shown. If you select the File option, you must then enter a filename after the Communication port in the control sequences (see Fig. 2.6).

2-12

9610a

Page 39

FST 200

2. Setting up the software

The printer control sequences for a printer will be saved separately if you have modified them. You will then be able to decide, when selecting a printer, whether you wish to use the default control sequences or the modified control sequences for printing.

Please note the settings of the dip switches in the printer. You should refer to the printer manual for these.

2.2.4 Setting the printer control sequences Select function F2 if you wish to modify the printer control sequences. You will then see the following display.

Fig. 2.6: Printer control sequences

9610a

2-13

Page 40

FST 200

2. Setting up the software

You will find the current printer type on the right of the header line. You can modify the control characters by overwriting the individual characters. The last line defines the printer port. Binding margin You should remove the binding margin if you are printing out an STL program with comments. Do this by deleting with the Delete key all the spaces after the after the Line feed and Carriage return characters (highlighted). Insert more spaces if you wish to have a wider binding margin. This is done by pressing the Insert key once and then the space bar several times. Do not forget to press the Insert key again afterwards. Modifying control characters You can overwrite the characters entered if your printer requires characters other than those given as defaults. After pressing the Insert key, enter the characters at the current cursor position. Delete any superfluous characters with the Delete key. You must read your printer manual with regard to the modification of the printer commands.

2-14

9610a