Page 271

FST 200-LDR

5. Programming in ladder diagram

Symbol

Contents of the operand 1 0

Presentation of the operand inverse conventional

Coil (reset)

0 1 inverse conventional

Coil (assignment)

1 0 inverse conventional

Coil (assignment negated)

0 1 inverse conventional

Coil (set)

Example: If an operand with the value 0 is to be reset, it is shown in inverse video. Counter The operand for the counter status is shown inversely during decrementation if its value is one (counter active).

The values of multibit operands can only be viewed by function F4 Show operands. The following mask shows the status display of an example program. Symbols displayed in inverse video are shown against a black background.

9610a

5-93

Page 272

FST 200-LDR

5. Programming in ladder diagram

Fig. 5.29: Status display The functions you can now activate via the menu system are described in the following:

5-94

9610a

Page 273

FST 200-LDR

5. Programming in ladder diagram

Changing the scanning frequency The scanning frequency determines how quickly the statuses and values of operands in the rung are to be interrogated. The frequency of interrogation depends on the number of operands in the rung. The factor 100 indicates the maximum frequency. The default rate is factor 50. By activating function F1 (Faster) or F2 (Slower), the scanning frequency can be increased or decreased in steps of 5. The current scan rate is shown in the message line. The flashing star indicates the interrogation rate in the marked rung.

Please note that a high interrogation rate can considerably slow execution of the program in the controller.

9610a

5-95

Page 274

FST 200-LDR

5. Programming in ladder diagram

Change operand value This function allows you to change the values of one-bit and multibit operands for test purposes. Activate function F3 to call up a data input window.

Fig. 5.30: Modifying operands In the first line, enter the operand the value of which you wish to change and press the Enter key. The actual value of the operand is then shown in line 2. In the third line, enter the desired nominal value of the operand. All input formats (e.g. hexadecimal) are allowed. Please note the permissible ranges of the operand values (refer to Appendix A1.2). Activate function F1 Execute to enter the value into the controller.

5-96

9610a

Page 275

FST 200-LDR

5. Programming in ladder diagram

Display operand value This function allows you to display the current value of an operand. The current value of the operand is then always displayed in the message line (dynamic display). Function F6, Display format can be used to set the display format. First, a prompt appears in the message line:

Which operand for dynamic display? Enter the operand name and press the Enter key to confirm. If you wish to display a different operand, terminate the output by activating function F8 End operand display. Now you can reactivate the function Display operand and select the new operand for display.

9610a

5-97

Page 276

FST 200-LDR

5. Programming in ladder diagram

Display format Function F6 allows you to set the output format for the operand value. The current format is shown on the right of the message line. The possible formats are: • decimal without sign (Dec) • decimal with sign (Dec +/-) • hexadecimal (Hex)

Error messages Error messages due to defective connection are shown in the message line. In this event, check the connection between your computer and the controller.

5-98

9610a

Page 277

FST 200

6. Text editor

6. Text editor The text editor in the FST software package allows you to • Create and edit a text document relating to a project, • Create title pages for a project, • Define a page header to appear on each page of the printout. The texts you create using the text editor are automatically assigned to the current project. Therefore, before you use the functions of the text editor • You should make sure that the intended project has been activated, • If not, you should use the Select project function to select and activate the project.

9610a

6-1

Page 278

FST 200

6.1

6. Text editor

Description and functions To open the text editor activate the function (F3) Utility programs and then select the Texteditor option. You will then see the screen shown in Fig. 6.1.

WARNING. Please do not use the text editor to edit control programs. There are editors for this purpose in the various programming languages which will also permit you to carry out a syntax check. This check is not incorporated in the text editor (see section 4).

Fig. 6.1: Text editor

6-2

9610a

Page 279

FST 200

6. Text editor

The example in Fig. 6.1 gives a summary of the various options for text manipulation. Functions F1 to F8 take you from here to the various options. The following command levels are available: • You can use search commands to find and replace text. • Block commands are used to form, copy, move, delete and save text blocks. • Use tab commands to set, move or delete tab settings. • Editor help gives you a brief summary of how to use the editor. • File commands are used to save texts, to open or save text blocks and to quit the text editor. • Additional commands permit you to use simple editing functions within the text.

9610a

6-3

Page 280

FST 200

6. Text editor

6.1.1 Search commands Selecting function F1 from the screen shown in Fig. 6.1 switches function key assignment to the Search commands (see Fig. 6.2).

Fig. 6.2: Search commands text editor

6-4

9610a