The text of a manual · part 4 of 5

User's Manual: SW VGA / Ars Series, pages 13 to 24

Pages 13 to 24 of 28: Chapter 3 • Operation; Chapter 4 • Remote Control

The original document is the PDF (1.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Extron SW VGA Ars

Page 13

Installation, cont’d Configuring the switcher There are six jumpers on the circuit board, numbered JMP5, JMP7, JMP9, JMP11, JMP 13, and JMP15, that control connection with one or more VSW I AAP control panels (figure 2-9 and figure 2-10).

OPEN

CLOSED

All jumpers are set open (removed) by default. The jumpers in the table below must be set closed (installed) when a VSW I AAP is connected to the associated input. Close the indicated jumpers in the table below to adjust the appropriate settings.

VSW I AAP VSW I AAP connected to: Jumper connected to: Jumper Input 1

JMP5

Input 4

JMP11

Input 2

JMP7

Input 5

JMP13

Input 3

JMP9

Input 6

JMP15

Figure 2-10, Jumper positions vs. VSW I AAP input connections These jumpers enable/disable VGA connector pin 5 (control) for each input. Close (install) the jumper for a specific VGA input to allow the VSW I AAP’s “show me” signal to select that input. When an input is not connected via a VSW I AAP, that input’s jumper should be in the default (open) position. Each jumper, when closed (installed) allows the switcher to receive the “show me” signal from the VSW I AAP on that input’s VGA connector. When a jumper is open (removed) that input cannot receive the signal. Auto switch mode must be disabled when using the switcher with one or more VSW I AAP remote controls. If the auto switch mode is enabled, the input cannot be selected using the “show me” function.

2-12

SW VGArs / Ars Series Switchers • Installation

SW VGArs / Ars Series Switchers

3

Chapter Three

Operation Front Panel Controls and Indicators Front Panel Operations

Page 14

Operation Front Panel Controls and Indicators

3

The front panels are identical for the non-audio (SW VGArs) and audio (SW VGA Ars) models. Figure 3-1 shows the controls and indicators on the front panel of the SW6 VGArs / Ars Series switchers.

Mode is a secondary function of the Input 1 button. 4

Front panel buttons and LEDs 1

Auto Switch Active LED, When this LED is on, it indicates that the auto switch mode is active. 2 SW VGA/Ars SERIES

Mode button, Use this button, with either the Auto or the Normal button, to manually turn auto switch mode on or off.

Normal button, Use this button, with the Mode button, to manually turn auto switch mode off. Normal is a secondary function of the Input 2 button.

5

Auto button, Use this button, with the Mode button, to manually turn auto switch mode on. On 4-input and 6-input switchers, Auto is a secondary function of the Input 3 button.

VGA/AUDIO SWITCHER

1

2

ACTIVE

MODE

NORMAL

AUTO

1

3

4

5

Front Panel Operations

AUTO SWITCH

Plug in all system components and turn on the input devices (such as desktop computers and laptops) and the output monitor. Select an input. The image should appear on the monitor.

2 SW VGA/Ars SERIES

Normal and auto switch modes

VGA/AUDIO SWITCHER

1

2

3

ACTIVE

MODE

NORMAL

AUTO

1

3

4

5

4

AUTO SWITCH

2 SW VGA/Ars SERIES VGA/AUDIO SWITCHER

1

2

3

MODE

NORMAL

AUTO

4

5

6

AUTO SWITCH

ACTIVE

1

3

4

5

Figure 3-1, Front panel (SW VGArs and SW VGA Ars front panels are identical). 2

Input selection buttons and LEDs, When the auto switch mode is off, use these buttons to select the input. The LED for the selected input lights.

All SW VGArs / Ars Series switchers can operate in either normal (manual switch) mode or auto switch mode. In auto switch mode, the highest numbered input with a sync signal present is automatically selected for output. If no sync signal is present, no input is selected. Input selection by the front panel buttons is blocked while the switcher is in auto switch mode. However, the front panel LEDs remain functional and the buttons can be used to view or change the mode. Viewing the current switch mode You can determine the current switch mode at any time by noting the state of the Auto Switch Active LED. This LED is lit if the switcher is in auto switch mode. Selecting normal switch mode Press and hold the Input 1/Mode button while you press and release the Input 2/Norm button. The Auto Switch Active LED turns off, indicating normal switch mode. Release the Input 1/Mode button.

The LEDs continue to indicate the selected input when auto switch mode is on. If no input LED is lit, no input has active sync pulses and no input is selected.

3-2

SW VGArs / Ars Series Switchers • Operation

SW VGArs / Ars Series Switchers • Operation

3-3

Page 15

Operation, cont’d Selecting auto switch mode Press and hold the Input 1/Mode button while you press and release the Input 3/Auto button. The Auto Switch Active LED turns on, indicating auto switch mode. Release the Input 1/Mode button. Auto switch mode must be disabled when using the switcher with one or more VSW I AAP remote controls. If the auto switch mode is enabled, the input cannot be selected using the “show me” function.

Locking the front panel (Executive mode) To toggle the front panel lock on and off, press and hold the Input 2/Normal button and the Input 3/Auto button for approximately 3 seconds. All front panel LEDs flash three times to indicate the mode change. All input LEDs blink once if you attempt a front panel operation while the panel is locked.

Selecting an input in normal switch mode To select an input using the front panel buttons, press and release the button for the desired input (must be in normal switch mode). The LED for the selected input lights. An input can also be selected by an RS-232 device or a remote control device (see chapter 4, “Remote Control”).

SW VGArs / Ars Series Switchers

4

Chapter Four

Remote Control Simple Instruction Set Control Windows-Based Program Control VSW I AAP Remote Control Contact Closure Remote Control IR 102 Infrared Remote Control

3-4

SW VGArs / Ars Series Switchers • Operation

Page 16

Remote Control The SW VGArs / Ars Series switcher’s rear panel Remote connector (figure 4-1) can be connected to the serial port output of a host device, such as a computer or control system, to an Extron IR 102 Kit Universal Remote Control, OR to a remote contact closure device. Other than the IR 102 Kit, remote communications with the switcher are via the Extron Simple Instruction Set (SIS™) or under Windows®-based control program; or they can be pin-programmed for use with a contact closure device.

REMOTE

PIN 1 2 3 4 5 6 7 8 9

RS-232, TX RX, Gnd, - - - Contact Closure In #1, - In #2 Gnd In #3 In #4 In #5 In #6

Function Input #1 Transmit data Receive data Input #2 Ground Input #3 Input #4 Input #5 Input #6

Figure 4-1, Remote connector pinout The RS-232 protocol of the rear panel Remote connector is 9600 baud, 1 stop bit, no parity, and no flow control. The connector has the pin assignments shown in figure 4-1. For RS-232 and IR control, use a control cable with only pins 2, 3, and 5 connected. To accomplish this, either cut the wires to the other pins in hard-shelled connectors, or remove the unneeded pins from molded plugs. For contact closure, use a control cable with pins 2 and 3 NOT connected. To accomplish this, either cut the wires to these pins in hard-shelled connectors or remove these pins from molded plugs.

Simple Instruction Set Control Host-to-switcher communications SIS commands consist of one or more characters per field. No special characters are required to begin or end a command character sequence. When a command is valid, the switcher executes the command and sends a response to the host device. All responses from the switcher to the host end with a carriage return and a line feed (CR/LF = ), which signals the end of the response character string. A string is one or more characters.

4-2

SW VGArs / Ars Series Switchers • Remote Control

Switcher-initiated (unsolicited) messages When a local event, such as a front panel operation or error condition, occurs, the switcher responds by sending a message to the host. The switcher-initiated messages are listed below: (C) Copyright 2002, Extron Electronics SWy VGArs, Vx.xx The switcher issues the copyright message when it first powers on. Vx.xx is the firmware version number. Inn•All The switcher issues the Inn message when a front panel input selection operation occurs. n is the input number. Reconfig The switcher initiates this message when there is a change in an audio model’s audio gain setting. Sig•n•n•n•n•n•n The switcher initiates this message when there is a change in the status of an input. n = 1 indicates the video signal is present, n = 0 indicates the video signal is not present. There are as many ns in the switcher-initiated message as the maximum number of inputs for the models (2, 4, or 6). For example, the response Sig•1•1•1•0•1•0 shows that the input signal is present on inputs 1, 2, 3, and 5, and that no signal is present on inputs 4 and 6.

Error responses When the switcher receives a valid SIS command, it executes the command and sends a response to the host device. If the switcher is unable to execute the command because the command is invalid or it contains invalid parameters, the switcher returns an error response to the host. The error response codes are: E01, Invalid input channel number (out of range) E06, Invalid input channel change (auto-switch mode active) E09, Invalid function (mode) parameter E10, Invalid command E13, Invalid value (out of range) E14, Illegal command for this configuration

SW VGArs / Ars Series Switchers • Remote Control

4-3

Page 17

4-4 = space

X1

= Input number 0 through 6 (0 = output mute)

X2

= Input signal status 0 = no signal detected 1 = signal detected

X3

= On/off status 0 = off 1 = on

X4

= Software version x.xx

X5

= Switch mode 1 = normal switch mode 2 = auto switch mode

ASCII to HEX Conversion Table •

SW VGArs / Ars Series Switchers • Remote Control Sig•1•1•1•0•1•0 X2

0S X1 S

Example (SW6 VGArs):

SW VGArs / Ars Series Switchers • Remote Control

Amt X3

0 Z/z Z/z

Unmute audio Read audio mute

X3

Amt X3

1 Z/z Mute audio

Audio Mute

B/b Read video mute

X3

Vmt X3 Vmt X3

1 B/b 0 B/b

Mute video Unmute video

Video Mute

Request one input’s status

Sig• X2 1• X2 2•...• X2 n

0S

Audio mute status

Audio mute off

Audio mute on

Video mute status

Video mute off

Video mute on

Each X2 response is the signal status of an input, starting from input 1; n is the maximum number of inputs for this model. The input signal is present on inputs 1, 2, 3, and 5. No signal is present on inputs 4 and 6. X1 ’s signal status = X2 .

Select input X1 video and audio. Select input X1 video only (audio breakaway). Select input X1 audio only (audio breakaway).

Timeout

Request all inputs’ status

Input video sensing

X1 $

In X1 All In X1 Vid In X1 Aud

Using the command/response table

X1 &

X1 !

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The command operation is aborted with no other indication.

Select video and audio input Select video input only Select audio input only

Input selection

Response (switcher to host)

(host to switcher)

= CR/LF (carriage return/line feed) (0x0D 0A)

ASCII Command

Symbol definitions

Command

The command/response table is on the next page. Lowercase letters are allowed in the command field only as indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command/response table.

Additional description

•

Command/response table for SIS commands

Remote Control, cont’d

4-5

Page 18

= space

0 through 6 (0 = output mute)

Timeout

= Input number

Pauses of 10 seconds or longer between command ASCII characters result in a timeout. The command operation is aborted with no other indication.

•

0 = no signal detected 1 = signal detected

Using the command/response table

X1

= Input signal status

0 = off 1 = on

The command/response table is on the next page. Lowercase letters are allowed in the command field only as indicated. Symbols are used throughout the table to represent variables in the command/response fields. Command and response examples are shown throughout the table. The ASCII to HEX conversion table below is for use with the command/response table.

X2

= On/off status x.xx

Symbol definitions

X3

= Software version

1 = normal switch mode 2 = auto switch mode

= CR/LF (carriage return/line feed) (0x0D 0A)

X4

= Switch mode

•

X5

ASCII to HEX Conversion Table

SW VGArs / Ars Series Switchers • Remote Control Command

SW VGArs / Ars Series Switchers • Remote Control

ASCII Command

Response

(host to switcher)

(switcher to host)

Additional description

X1 ! X1 $

In X1 All In X1 Vid In X1 Aud

Select input X1 video and audio. Select input X1 video only (audio breakaway). Select input X1 audio only (audio breakaway).

Request all inputs’ status

0S

Sig• X2 1• X2 2•...• X2 n

Example (SW6 VGArs):

0S

Sig•1•1•1•0•1•0

X1 S

X2

Each X2 response is the signal status of an input, starting from input 1; n is the maximum number of inputs for this model. The input signal is present on inputs 1, 2, 3, and 5. No signal is present on inputs 4 and 6. X1 ’s signal status = X2 .

Input selection Select video and audio input Select video input only Select audio input only

X1 &

Input video sensing

Request one input’s status

Video Mute Mute video

1 B/b

Vmt X3

Video mute on

Unmute video

0 B/b

Vmt X3

Video mute off

Read video mute

B/b

X3

Video mute status

Audio Mute Mute audio

1 Z/z

Amt X3

Audio mute on

Unmute audio

0 Z/z

Amt X3

Audio mute off

Read audio mute

Z/z

X3

Audio mute status

Remote Control, cont’d

4-4

Command/response table for SIS commands

4-5

Page 19

Additional description Front panel mode

(switcher to host)

1# 2#

F1 F2

Set switch mode to normal. Set switch mode to auto (auto-switch). Set normal switch mode Set auto switch mode

Response (host to switcher)

Command

ASCII Command

Front panel lock (Executive mode) 1X 0X

Exe1 Exe0

Lock front panel controls. Unlock front panel controls. Show front panel lock status

X

X3

Show front panel lock status, 0 = unlocked, 1 = locked).

View, information, part number, and firmware requests

Software version x.xx.

Information request Example

I/i

Request for part number

N/n

V X1 •A X1 •F• X5 •Vmt X3 •Amt X3 V2•A2•F•2•Vmt 0•Amt 1 Video input 2; audio input 2; front panel mode auto; video not muted, audio muted. 60-xxx-xx Query software version

Q/q

X4

SW VGArs / Ars Series Switchers • Remote Control

Lock front panel Unlock front panel

Remote Control, cont’d

4-6

Command/response table for SIS commands (continued)

Windows-Based Program Control

The Windows-based Extron Universal Switcher Control Program, which communicates with the switcher via the RS-232 port, provides an easy way to configure and operate the SW VGArs / Ars Series switchers. The program is compatible with Windows 2000 and Windows XP.

Installing the software

The program is contained on the Extron Software Products disk. Install the software as follows: 1.

Insert the disk into the drive. The installation program should start automatically. If it does not self-start, run Launch.exe from the disk.

The Extron software disk window appears (figure 4-2).

Click the Software tab (figure 4-2).

Figure 4-2, Software disk window 2.

Scroll to the desired program and click Install (figure 4-3).

4-7

3.

Figure 4-3, Software installation

SW VGArs / Ars Series Switchers • Remote Control

Page 20

Remote Control, cont’d

4-6

The program is contained on the Extron Software Products disk. Install the software as follows: 1.

Insert the disk into the drive. The installation program should start automatically. If it does not self-start, run Launch.exe from the disk. The Extron software disk window appears (figure 4-2).

X4

Software version x.xx.

Installing the software

Q/q

N/n

V X1 •A X1 •F• X5 •Vmt X3 •Amt X3 V2•A2•F•2•Vmt 0•Amt 1 Video input 2; audio input 2; front panel mode auto; video not muted, audio muted. 60-xxx-xx I/i

The Windows-based Extron Universal Switcher Control Program, which communicates with the switcher via the RS-232 port, provides an easy way to configure and operate the SW VGArs / Ars Series switchers. The program is compatible with Windows 2000 and Windows XP.

Query software version

Request for part number

Figure 4-2, Software disk window

Information request Example

View, information, part number, and firmware requests

F1 F2 1# 2# Set normal switch mode Set auto switch mode

(host to switcher)

Front panel mode

Response

(switcher to host)

ASCII Command Command

Command/response table for SIS commands (continued)

Additional description

Set switch mode to normal. Set switch mode to auto (auto-switch).

Windows-Based Program Control

SW VGArs / Ars Series Switchers • Remote Control

2.

Click the Software tab (figure 4-2).

3.

Scroll to the desired program and click Install (figure 4-3).

Figure 4-3, Software installation

SW VGArs / Ars Series Switchers • Remote Control

4-7

Page 21

Remote Control, cont’d 4.

Follow the on-screen instructions. By default, the Windows installation of the Universal Switchers Control Program creates a C:\Program Files\Extron\UnivSW, and it places four icons into a group folder named “Extron Electronics\Universal Switcher.” The four installed icons are: • Check for Universal Switcher Updates • Uninstall Universal Switcher • Universal Switcher Control Program • Universal Switcher Help

In figure 4-4: indicates that the video input is selected. indicates that the audio input is selected. indicates that the input is not selected. indicates that the video input signal is present.

Using the software indicates that no video input signal is present.

Run the program as follows: 1.

Click Start > Programs > Extron Electronics > Universal Switcher Control Pgm.

2.

Click the comm port that is connected to the switcher’s RS-232 port.

3.

The Extron Universal Switcher Control Program window (figure 4-4) displays the input signal status for each input (signal present or not present) and the selected input.

Updating firmware If firmware updates are implemented for the SW VGA Ars, they are made available on the Extron Web site, www.extron.com. The Firmware Loader software is also available from the Extron site. Use the SIS “Q” command to determine the switcher’s current firmware level. Downloading the firmware from the Web site To obtain the latest version of firmware for your SW VGA Ars switcher: 1.

Visit the Extron Web site, www.extron.com, click the Download tab, then click the Firmware link on the left sidebar menu.

Figure 4-5, Extron Web site Download Center Figure 4-4, Universal Switcher Control program window

4-8

SW VGArs / Ars Series Switchers • Remote Control

SW VGArs / Ars Series Switchers • Remote Control

4-9

Page 22

Remote Control, cont’d 2.

On the Download Center screen, click the SW VGA Series Download link.

Loading the firmware to the switcher To load a new version of firmware to your SW VGA Ars switcher, call the Firmware Loader software from within the Universal Switcher Control Program. Your computer’s serial port must be connected to the switcher’s serial port. See chapter 2, “Installation,” for more information. 1.

If necessary, download the Firmware Loader installer executable file to your computer, as follows: a.

On the Extron Web page, click the Download tab.

b.

On the Download Center page, click Software on the left sidebar menu.

c.

Locate the “Firmware Loader” line and click the Download link at the far right.

d.

Follow the instructions on the download screens to save the installer file to your computer.

e.

In the Windows Explorer or other file browser, locate the Firmware Loader executable file in your computer’s file system and double-click on it to open it.

f.

Follow the instructions on the Installation Wizard screens to install the Firmware Loader on your computer. Unless you specify otherwise, the installer program places the Firmware Loader file, “FWLoader.exe” in c:\Program Files\Extron\FWLoader.

Figure 4-6, SW VGA Ars firmware 3.

Complete the Personal Information form and click the Download button.

Figure 4-7, Personal information form 4.

Follow the instructions on the rest of the download screens to save the executable firmware file to your computer. Note the folder to which you save the file.

5.

In the Windows Explorer or other file browser, locate the downloaded executable file, and double-click on it to open it.

6.

4-10

Follow the instructions on the Installation Wizard screens to install the new firmware on your computer. A Release Notes file, giving information on what has changed in the new firmware version, and a set of instructions for updating the firmware are also loaded.

SW VGArs / Ars Series Switchers • Remote Control

If the Extron and FWLoader folders do not yet exist in your Program Files folder, the installer creates them. 2.

In the Universal Switcher Control Program, click the Firmware Loader button. If the Firmware Loader button does not appear in the Universal Switcher Control Program window, the Firmware Loader software is not installed.

SW VGArs / Ars Series Switchers • Remote Control

4-11

Page 23

Remote Control, cont’d 3.

If you have not updated firmware for the SW VGA switcher before, on the Add Device screen, select the RS-232 tab.

7.

If you have updated firmware for this model, click Cancel. The Firmware Loader window appears. Proceed to step 6.

Navigate to and select the new firmware file. The Choose Firmware File window closes. When downloaded from the Extron Web site, the firmware is placed at C: Program Files\Extron\Firmware\SW .

CAUTION

The firmware file must have a .s19 extension. Other file types can cause the switcher to stop functioning.

Figure 4-8, Add Device screen Although the screen also has a TCP/IP tab, the switcher does not have a LAN port. Do not select the TCP/IP tab. 4.

5.

From the drop-down menus on the RS-232 screen, select the appropriate Com port number (obtained from your system administrator) and baud rate (the default is 9600).

Figure 4-10, Choose Firmware File window 8.

In the Firmware Loader window, click Begin. The Total Progress and Progress status bars show the progress of the upload. The firmware upload to the switcher may take several minutes. Once the status bars have progressed from 0% to 100%, and Status is listed as Complete, the firmware loader utility resets the switcher.

Click OK. The Firmware Loader window appears.

Figure 4-9, Extron Firmware Loader window 6.

Select the SW VGArs and click File > Open. The Choose Firmware File screen appears.

Figure 4-11, Extron’s Firmware Loader screen 9.

4-12

SW VGArs / Ars Series Switchers • Remote Control

Click Exit to close the Firmware Loader.

SW VGArs / Ars Series Switchers • Remote Control

4-13

Page 24

Remote Control, cont’d Using the help system

Contact Closure Remote Control

For information about program features, you can access the help program in any of the following ways: •

Click Start > Programs > Extron Electronics > Universal Switcher Control Help.

•

From within the Windows-based switcher control program, select Help > Contents on the task bar.

•

From within the Windows-based switcher control program, press the F1 key.

The Remote connector also provides a way to select an input to the switcher using a remote contact closure device. Contact closure control uses pins on the Remote connector that are not used by the RS-232 interface. The contact closure pin assignments are shown in figure 4-1 on page 4-2. To select a different input number using a contact closure device, momentarily short the pin for the desired input number to logic ground (pin 5). To force one of the inputs to be always selected, leave the short to logic ground in place. The short overrides front panel input selections.

VSW I AAP Remote Control Each input of an SW VGArs / Ars Series switcher can be connected to a VSW I AAP passive interface. The VSW I AAP features a computer video input and pass-through, an unbalanced stereo input and pass-through, and an input select (Show Me) button. Pressing the VSW I AAP’s Show Me button causes the switcher to select the input connected via that AAP.

IR 102 Infrared Remote Control The optional Extron IR 102 kit consists of the following components: •

IR 102 handheld remote control unit

•

VersaTools IR 102 remote receiver with 3-foot cable and RS-232 connector

•

IR detector with 6-foot cable and captive screw connector

•

External 12 VDC power supply

Projector

SHOW ME AUDIO

SHOW ME AUDIO

VSW I AAP

COMPUTER

COMPUTER

VSW I AAP

VSW I AAP

100-240V

0.2A

Install and operate the remote control in accordance with the IR 102 User’s Guide included with the remote.

SHOW ME AUDIO

VSW I AAP

COMPUTER

VSW I AAP

VSW I AAP

REMOTE

INPUTS

SW6 VGA Ars Switcher

3

2

4

0.2A

1

3

OUTPUT

L

2

4

SW6VGA VGAArs Ars SW6

5 OUTPUT

50-60Hz

6

REMOTE

INPUTS

5 OUTPUT

50-60Hz

Power Supply

SW6VGA VGAArs Ars SW6 100-240V

1

6

OUTPUT

L

R

3' Cable

R

RS-232 Control

SW6 VGA Ars

6' Cable IR-102

+10

IR 102

IR 102 Remote Control

SHOW ME AUDIO COMPUTER

VSW I AAP

VSW I AAP

SHOW ME AUDIO COMPUTER

VSW I AAP

VSW I AAP

SHOW ME AUDIO COMPUTER

IR Detector

IR 102 Remote Control Receiver

Figure 4-13, IR 102 Remote application

VSW I AAP

VSW I AAP

Figure 4-12, VSW I AAP application

4-14

SW VGArs / Ars Series Switchers • Remote Control

SW VGArs / Ars Series Switchers • Remote Control

4-15