Page 71

IPL T S Series

A Appendix A

Specifications, Part Numbers, Accessories Specifications Part Numbers and Accessories

Page 72

Specifications, Part Numbers, Accessories Specifications Ethernet control interface Connectors ������������������������������������� 1 female RJ-45 connector Data rate ����������������������������������������� 10/100Base-T, half/full duplex with autodetect Protocols ����������������������������������������� ARP, ICMP (ping), IP, TCP, UDP, DHCP, HTTP, SMTP, Telnet Default settings ������������������������������ Link speed and duplex level = autodetected IP address = 192.168.254.254 Subnet mask = 255.255.0.0 Gateway = 0.0.0.0 DHCP = off Web server �������������������������������������� Up to 200 simultaneous sessions 7.25 MB nonvolatile user memory Program control ����������������������������� Extron Simple Instruction Set (SIS™) Global Viewer requirements �������� Microsoft® Internet Explorer ver. 6 or higher

Serial control interface Quantity/type IPL T S1 ������������������������������� 1 RS-232-only IPL T S2 ������������������������������� 2 RS-232/RS-422/RS-485 configurable serial IPL T S4 ������������������������������� 4 RS-232/RS-422/RS-485 configurable serial IPL T S6 ������������������������������� 2 RS-232/RS-422/RS-485 configurable serial 4 RS-232-only Connectors IPL T S1 ������������������������������� 1 male 9-pin D IPL T S2 ������������������������������� 2 male 9-pin D and (1) 3.5 mm captive screw connector, 5 pole IPL T S6 ������������������������������� 2 male 9-pin D and (1) 3.5 mm captive screw connector, 10 pole IPL T S4 ������������������������������� 4 male 9-pin D Baud rate and protocol ����������������� 300 to 115200 baud Default settings (adjustable): 9600 baud, 8 data bits, 1 stop bit, no parity Pin configurations Serial, 9-pin D (IPL T S1) RS-232 ������������������������� 2 = RX, 3 = TX, 5 = GND, 7 = RTS, 8 = CTS Serial, 9-pin D (IPL T S2, IPL T S4) RS-232 (default) ��������� 2 = RX, 3 = TX, 5 = GND, 7 = RTS, 8 = CTS RS-422 ������������������������� 2 = RX-, 3 = TX-, 5 = GND, 7 = TX+, 8 = RX+ RS-485 ������������������������� 2&3 (tied together) = data-, 5 = GND, 7&8 (tied together) = data+ Serial, 5-pole captive screw IPL T S2 ����������������������� COM1: pin 1 = TX, 2 = RX, 3 = GND COM2: pin 4 = TX, 5 = RX, 3 = GND Serial, 10-pole captive screw IPL T S6 ����������������������� COM3: pin 1 = TX, 2 = RX, 3 = GND COM4: pin 4 = TX, 5 = RX, 3 = GND COM5: pin 6 = TX, 7 = RX, 8 = GND COM6: pin 9 = TX, 10 = RX, 8 = GND

General Power ���������������������������������������������� Supplied by an included external power supply External power supply ����������������� 100 VAC to 240 VAC, 50-60 Hz, external; to 12 VDC, 2 A, regulated Power input requirements ����������� 12 VDC, 0.5 A Temperature/humidity ���������������� Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing Mounting

A-2

IPL T S Series • Specifications, Part Numbers, Accessories

Page 73

Rack mount ������������������������ Yes, with optional 1U rack shelf Furniture mount ���������������� Under-furniture mountable with optional kit Pole mount ������������������������� Yes, with optional pole mount kit Enclosure type ������������������������������� Metal Enclosure dimensions IPL T S1 ������������������������������� 1.0" H x 4.3" W x 3.0" D (quarter rack wide) (2.5 cm H x 10.9 cm W x 7.6 cm D) (Depth excludes connectors.) All other models ���������������� 1.7" H x 4.3" W x 3.0" D (1U high, quarter rack wide) (4.3 cm H x 10.9 cm W x 7.6 cm D) (Depth excludes connectors.) Product weight ������������������������������ 0.7 lbs (0.3 kg) Shipping weight ���������������������������� 2 lbs (1 kg) Vibration ����������������������������������������� ISTA 1A in carton (International Safe Transit Association) Regulatory compliance Safety ����������������������������������� CE, c-UL, UL UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release, excluding the power supply; meets UL 60950 for safety. EMI/EMC �������������������������� CE, C-tick, FCC Class A, ICES, VCCI MTBF ����������������������������������������������� 30,000 hours Warranty ����������������������������������������� 3 years parts and labor

N All nominal levels are at ±10%. N Specifications are subject to change without notice.

IPL T S Series • Specifications, Part Numbers, Accessories

A-3

Page 74

Specifications, Part Numbers, Accessories, cont’d Part Numbers and Accessories Included parts Included parts

Replacement part number

IPL T S1

60-801-81

IPL T S2

60-544-81

IPL T S4

60-544-83

IPL T S6

60-544-84

Power supply; external 12 VDC, 1 A (U.S., Canada)

70-055-01

Power supply; external 12 VDC, 1 A (International)

70-055-02

IEC power cord Rubber feet (4) Velcro®; industrial strength strip Captive screw connector; female 3.5 mm, 5-pole

10-319-10

Captive screw connector; female 3.5 mm, 2-pole

10-319-05

Captive screw connector; female 3.5 mm, 2-pole (orange)

10-702-10LF

Tweeker IPL T S Series Setup Guide

Optional accessories Accessories

A-4

Part number

RSF 123 1U 3.5-inch Deep Rack Shelf Kit

60-190-20

RSU 129 1U 9.5-inch Deep Universal Rack Shelf Kit

60-190-01

MBU 123 Under-Desk Mount Kit

70-212-01

PMK 100 Mini Projector Mounting Kit

70-217-01

MBU 125 Under-Desk Mount Kit (for S1 only)

70-077-01

PMK 200 Projector Mount Kit (for S1 only)

70-077-04

IPL T S Series • Specifications, Part Numbers, Accessories

Page 75 read from a scan by OCR; it may hold reading errors

IPL TS Series

Appendix B

Glossary

Glossary

Page 76

Glossary Glossary

10/100Base-T is Ethernet that uses Unshielded Twisted Pair (UTP - CAT 5, and so on.) cable, on which the amount of data transmitted between two points in a given amount of time is equal to either 10 Mbps or 100 Mbps. Address Resolution Protocol (ARP) is a protocol that assigns an IP address to a device based on the device’s MAC or physical machine address. Custom Web page is any file that can be loaded into an IPL T S interface and served by the unit’s internal Web server. A custom Web page can provide control of devices attached to the unit without use of Global Configurator (GC) or GlobalViewer® (GV). This is true with or without an accompanying event script. Any number and size of graphics can be used, but if they are too large to fit on the IPL T S interface, you can write your Web page so that they can be served from another Web server. If you install Microsoft® Internet Information Services (IIS) on your desktop, you can serve any page on its hard disk. The IPL T S unit functions like a little computer with a Web server, you can use it for various Web tasks. DataViewer allows you to send ASCII or hexadecimal commands to an Extron IPL T S interface and view the device’s responses. You can configure the data display in several ways, including selecting the text color, text font, and whether to view commands and responses in separate panes within the DataViewer window. The software can save the command/response data as a text file (.txt) or as an HTML file that preserves some of the display formatting. Default Web pages are a set of preloaded Web pages that can be accessed via a standard Web browser. These pages are a primary means of initial setup for IP Link® products and a way to change their settings. Web browsers such as Netscape® Navigator (version 6.0 or higher), or Internet Explorer® (version 5.5 or higher) can be used, but if using Internet Explorer, you must also have Microsoft Script (version 5.6 or higher). DHCP is the Dynamic Host Configuration Protocol (DHCP), which is a standardized communications protocol that enables network administrators to locally and automatically manage the assignment of IP addresses in an organization’s network. Driver is a GC compatible package. It includes the event script that controls devices. Ethernet is a network protocol that uses MAC addresses instead of IP addresses to exchange data between computers. Using ARP (see Address Resolution Protocol), with TCP/IP support, Ethernet devices can be connected to the Internet. An Ethernet LAN typically uses unshielded twisted pair (UTP) wires. Ethernet systems currently provide transmission speeds of 10 Mbps or 100 Mbps. Event script is a program that runs on an IPL T S interface, and issues queries and commands to the attached devices. Event scripts are written in the “Extron C” language (as .sc files), and are compiled into event scripts using GC. The results are compiled as .evt files and loaded onto the IPL T S device. The Extron C language is similar to ANSI C, with some differences. As long as event scripts are turned on, they run on the device continuously. Global Configurator (GC) is a Windows® program that, based on user input, creates the GlobalViewer pages. Global Configurator requests system information such as which devices you have and your current list of IP addresses. With this information, GC creates a GV page for your specific devices. GC also compiles the event scripts and loads the GV pages and event scripts onto the device. When using GC, you must specify the port number for each device (for attached devices to be controlled, they must be on that port). In order for multiple IP Link® devices to appear in the same GV page, all devices must be configured at the same time using GC.

B-2

IPL T S Series • Glossary

Page 77

GlobalViewer (GV) is a set of Web pages (HTML, XML, JS) and graphics that are loaded into the memory of an IPL T S interface. These pages provide an interface for control of devices attached to the IPL T S interface. They communicate with the event scripts running on the device, and the event scripts issue the commands and queries. This communication between the Web pages and the event scripts occurs through predetermined memory locations in the IPL T S interface. GV is initially created by Global Configurator; however, it is possible to edit GV’s HTML, XML, and JavaScript files outside of GC. This edited GV is called “hard-coded” or manually generated GlobalViewer. HTTP is an acronym for the HyperText Transfer Protocol (HTTP), a Web protocol based on TCP/IP, that is used to fetch HyperText objects from remote Web pages. Internet Protocol (IP) is the protocol or standard used to send information from one computer to another on the Internet. IP address is a unique, 32-bit binary number (up to a 12 digit decimal number, xxx.xxx.xxx.xxx) that identifies each sender and each receiver of information connected to a LAN, WAN, or the Internet. IP addresses can be static (see Static IP) or dynamic (see DHCP). IP Netmask is a 32-bit binary number (12 digit decimal number, xxx.xxx.xxx.xxx) used on subnets (smaller, local networks) to help the router determine which network traffic gets routed internally to local computers and which network traffic goes out on the Internet. Media Access Control (MAC) Address is a unique hardware number given to devices that connect to the Internet. When your computer or networking device (router, hub, interface, etc.) is connected to the Internet, a table (see ARP) associates the device’s IP address to its corresponding physical (MAC) address on the LAN. Pass-through allows control systems to work with the IPL T S interface, and provides a link between two ports. Ping is a utility that tests network connections. It is used to determine if the host has an operating connection and is able to exchange information with another host. Port number is a preassigned address within a server that provides a direct route from the application to the Transport layer or from the Transport layer to the application of a TCP/IP system. Static IP refers to an IP address that has been specifically (instead of dynamically, see DHCP) assigned to a device or system in a network configuration. This type of address requires manual configuration of the actual network device or system and can only be changed manually or by enabling DHCP. Transmission Control Protocol/Internet Protocol (TCP/IP) is the communication protocol (language) of the Internet. Computers and devices with direct access to the Internet are provided with a copy of the TCP/IP program to allow them to send and receive information in an understandable form. Telnet is a utility available on most PCs that allows the computer system to communicate with one of its remote users/clients. A user who wishes to access a remote system initiates a Telnet session, using the address of the remote client. The user may be prompted to provide a user name and password if the client is set up to require them. URL encoding allows you to send information and commands to the unit to change its configuration or provide you with feedback. Web Server resides on the IPL T S interface and provides storage of the default Web pages, GlobalViewer, and your custom Web pages.

IPL T S Series • Glossary

B-3

Page 78

Extron’s Warranty Extron Electronics warrants this product against defects in materials and workmanship for a period of three years from the date of purchase. In the event of malfunction during the warranty period attributable directly to faulty workmanship and/or materials, Extron Electronics will, at its option, repair or replace said products or components, to whatever extent it shall deem necessary to restore said product to proper operating condition, provided that it is returned within the warranty period, with proof of purchase and description of malfunction to: USA, Canada, South America, and Central America: Extron Electronics 1001 East Ball Road Anaheim, CA 92805 U.S.A.

Japan: Extron Electronics, Japan Kyodo Building, 16 Ichibancho Chiyoda-ku, Tokyo 102-0082 Japan

Europe, Africa, and the Middle East: Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands

China: Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China

Asia: Extron Asia 135 Joo Seng Road, #04-01 PM Industrial Bldg. Singapore 368363 Singapore

Middle East: Extron Middle East Dubai Airport Free Zone F12, PO Box 293666 United Arab Emirates, Dubai

This Limited Warranty does not apply if the fault has been caused by misuse, improper handling care, electrical or mechanical abuse, abnormal operating conditions or non-Extron authorized modification to the product. If it has been determined that the product is defective, please call Extron and ask for an Applications Engineer at (714) 491-1500 (USA), 31.33.453.4040 (Europe), 65.383.4400 (Asia), or 81.3.3511.7655 (Japan) to receive an RA# (Return Authorization number). This will begin the repair process as quickly as possible. Units must be returned insured, with shipping charges prepaid. If not insured, you assume the risk of loss or damage during shipment. Returned units must include the serial number and a description of the problem, as well as the name of the person to contact in case there are any questions. Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage. Please note that laws vary from state to state and country to country, and that some provisions of this warranty may not apply to you.

Page 79

Extron USA - West Headquarters +800.633.9876

Inside USA / Canada Only

+1.714.491.1500 +1.714.491.1517 FAX

Extron USA - East

Extron Europe

Extron Asia

Extron Japan

Extron China

Extron Middle East

+800.633.9876

+800.3987.6673

+800.7339.8766

+81.3.3511.7655 +81.3.3511.7656 FAX

Inside China Only

+400.883.1568

+971.4.2991800 +971.4.2991880 FAX

+1.919.863.1794 +1.919.863.1797 FAX

+31.33.453.4040 +31.33.453.4050 FAX

+65.6383.4400 +65.6383.4664 FAX

Inside USA / Canada Only

Inside Europe Only

Inside Asia Only

© 2010 Extron Electronics. All rights reserved.