Page 55
DVTel EV Series User Manual 4.) Select Using an IP network connection and click Start.
5.) In the Firmware File Selection dialog box, click Browse and select the correct firmware file.
6.) Click Next to view the verification screen. 7.) Click Start to begin the firmware update.
To update the firmware from the Home panel: 1.) In a web browser, type the IP address of the device in the Address bar, and then press ENTER. 2.) Type the username and password. 3.) From the Home panel, click Update located beside the firmware version. 4.) In the Firmware Update dialog box, click Browse and select the firmware file.
5.) Click Open. 6.) Click Start to begin updating the firmware of the unit.
52
Page 56
DVTel EV Series User Manual
To update the firmware from the Diagnose panel: 1.) In a web browser, type the IP address of the device in the Address bar, and then press ENTER. 2.) Type the username and password. 3.) From the Support folder, select Diagnose. 4.) From the Diagnose panel, click Update Firmware.
5.) In the Firmware Update dialog box, click Browse and select the firmware file.
6.) Click Open. 7.) Click Start to begin updating the firmware of the unit.
To perform a batch firmware update: The Device Configurator enables you to easily update the firmware for multiple devices via a network IP connection at the same time, rather than updating them individually. 1. On Latitude, select the network in which the devices are located. 2. Click on United Configurator and select Pro Line. 3. Click on the Discovery tab on the Navigation Bar and select all the EV devices that you wish to update. 4. Right-click on your mouse and select Batch Network Configuration. The Batch Network Configuration window opens. 5. You can select Use DHCP to automatically enter the network IP addresses or Static Configuration to manually enter the network IP addresses. 6. If you select Static Configuration, enter the Starting IP address and Ending IP Address that you wish to use. Also enter the Subnet Mask and Gateway addresses. 7. Click Apply. The system automatically performs the batch firmware update.
53
Page 57
DVTel EV Series User Manual
7.2
Using Recovery Mode
A device can reboot into recovery mode in one of the following situations:
The device failed to boot normally
The power or network connection to the device is lost during a firmware upgrade
A flashing orange LED (at one second intervals) or flashing orange LED (three blinks at one second intervals) and two quick red pulses (at half-second intervals) indicate the device failed to boot normally and has entered recovery mode. For more information on LED status, refer to Understanding the LED Indicators. When the device is in recovery mode, the only way to access the device is using Device Configurator or the Web Interface with reduced functionality. NOTE: If you are going to use Device Configurator to update the firmware of a device in recovery mode, you need to know the IP address of the device in order to access it. The Web Interface with reduced functionality is only accessible using the unsecure Hypertext Transfer Protocol (HTTP). A flashing orange LED (at one second intervals) indicates that the device is using a static IP address. A flashing orange LED (three blinks at one second intervals) and two quick red pulses (at half-second intervals) indicate that the device is using the APIPA address format. For more information on APIPA addressing, see Obtaining and Setting the IP Address. Once you have access to a device in recovery mode, the only way to exit recovery mode is to update the firmware using a valid firmware file.
7.3
Performing a Hardware Reset
Depending on the severity of the situation, you can reboot the device and load its default configuration, or perform both these actions if the device does not function the way it should. Start by rebooting the device to see if this restores functionality back to the device. See Rebooting the EV Series Device. If the device still does not function normally, restore the default configuration. See Restoring the Factory Default Settings.
7.4
Rebooting the EV Series Device
If the EV Series device does not function the way it should, you can reboot the device to reinitializes the settings.
54
Page 58
DVTel EV Series User Manual
To reboot the EV Series device using Device Configurator: 1.) Double-click EV Device Configurator.exe to start Device Configurator. 2.) Select the Units tab, then click Discover. 3.) Select the malfunctioning device and click Reboot. 4.) Click OK to confirm the reboot. 5.) Click Exit to close Device Configurator.
To reboot the edge device: 1.) In a web browser, type the IP address of the device in the Address bar, and then press ENTER. 2.) Type the username and password. 3.) From the Quick Launch bar, click the Reboot icon.
To reboot the EV Series device from the device: 1.) On device, press the Reset button.
7.5
Restoring the Factory Default Settings
If the device still does not function the way it should after rebooting, you can load the factory default configuration. This operation restores the factory default settings to the device and deletes all user-defined values.
To restore the factory default settings using Device Configurator: 1.) Double-click EV Device Configurator.exe to start Device Configurator. 2.) Select the Units tab, then click Discover. The information displayed for the EV Series device varies depending on whether you are using a static IP address or one assigned by a DHCP server.
3.) Select the device and click Configure.
55
Page 59
DVTel EV Series User Manual 4.) Click Load Default Settings.
5.) Click OK. The device reboots automatically. 6.) Click Exit to close Device Configurator.
To restore the factory default settings using the Web Interface: 1.) In a web browser, type the IP address of the device in the Address bar, and then press ENTER. 2.) Type the username and password. 3.) From the Administration folder, select Factory Default Settings.
56
Page 60
DVTel EV Series User Manual 4.) From the Factory Default Settings panel:
Select Restore to Factory Default Settings (Partial) if you want the unit to keep the network settings while restoring the default configuration
Select Restore to Factory Default Settings if you want to restore the unit back to the factory default configuration and remove all user settings
5.) Click Restore.
To restore the factory default settings using the hard reset: 1.) Press and hold the Reset button on the device until the status LED flashes red very rapidly.
NOTE: It can take up to 10 seconds for the system status LED to begin flashing red. 2.) Hold the button for an additional five seconds until the status LED changes color.
7.6
Losing Connection to a Camera
If the connection to a camera is lost while streaming video to Latitude, the software displays an error message on the screen and the streaming video displays red/blue frames. On the device, a steady red on any of the video status LEDs indicates that a connection to a camera is lost. In this case, perform the following tasks:
Check the connection between the device and the camera
Check the camera to ensure that it is transmitting video or that it is functioning correctly
Check the device to ensure that it is functioning correctly
57
Page 61
DVTel EV Series User Manual
8 Appendix The following items are included in this section:
Technical Specifications
Factory Default Configuration
Contacting DVTel Service and Support
Glossary
58
Page 62
DVTel EV Series User Manual
8.1
Technical Specifications
The following table presents the technical specifications for the DVTel EV Series devices: EV-208 EV-208-A EV-216 EV-216-A EV-116 Encoders
EV-101-D Decoder
EV-401-D Decoder
One composite, 1V p-p into 75Ω NTSC/ PAL, BNC female, 1 audio in, and 1 audio out
One HDMI output, 1 audio-in, and 1 audio-out
Video Input
Outputs/Connectors
H.264 Encoding Quadruple Stream Performance
Compression Resolution
Bandwidth
One, two, 8 or 16 composites, 1V p-p into 75Ω, NTSC/PAL, BNC female Two RJ-45, 8 or 16 BNC female video connectors, 4 or 8 3.5mm PL audio connectors (EV-208A and EV-216-A, respectively), one USB Dual-stream N/A EV-208 and EV216: 4CIF/30 fps + 2CIF/30 fps + CIF/15 fps on all channels simultaneously EV-116: D1/15 fps (H.264) H.264 Main Profile NTSC: Scalable from CIF (352 x 240 pixels) to 4CIF (704 x 480 pixels) PAL: Scalable from CIF (352 x 288 pixels) to 4CIF (704 x 576 pixels) Each stream configurable from 9 Kbps to 6 Mbps
Maximum Latency
115 msec
Tiles
N/A
N/A
N/A Yes 4 x D1/30 fps
NTSC: Scalable from CIF (352 x 240 pixels) to D1 (720 x 480 pixels) PAL: Scalable from CIF (352 x 288 pixels) to D1 (720 x 576 pixels) N/A
Scalable from SD to 720p or 1080i
Maximum of four tiles on one monitor. Tile display options: 1 x 1 and 2 x 2
59
Page 63
DVTel EV Series User Manual EV-208 EV-208-A EV-216 EV-216-A EV-116 Encoders
EV-101-D Decoder
EV-401-D Decoder
Network Interface 1 Interface 2 Protocols Security
RJ-45 Ethernet RJ-45 Ethernet (10/100 Mbps) (10/100/1000 Mbps) RJ-45 Ethernet N/A (10/100/1000 Mbps) for maintenance only RTP/IP, UDP/IP, TCP/IP or multicast IP, DNS, NTP, SNMP v1/v2/v3 (MIB-II), HTTP, HTTPS, DHCP and 802.1x SSL-based authentication, password protected, HTTPS
Serial and USB Ports Electrical
Operating Mode USB
Port 1: RS-232 (max. 230 kbps) pluggable screw terminal strip.
RS-232 (max. 230 kbps) pluggable clip terminal strip or RS-422/485 two/four wires (max. 230 kbps) pluggable clip terminal strip.
Port 2: RS-422/485 two/four wires (max. 230 kbps) pluggable screw terminal strip. Transparent serial port supporting any asynchronous serial protocol 1 USB host port N/A (USB drive not included)
Alarm Input
Output
EV-208: 8 dry contacts EV-216: 16 dry contacts EV-208: Two relay contacts (48V AC/DC at 500 mA max.)
Two dry contacts
One relay contact (48V AC/DC at 100 mA max.)
EV-216: Four relay contacts (48V AC/DC at 500 mA max.)
60