Page 11
Adjusting the Backlight Brightness levels of the liquid crystal display (LCD) are adjustable based on the lighting conditions. By default the level is set to 7. (0 being the lowest and 7 being the highest level) To adjust the level of backlight:
Start>Control Panel. Choose the DLI Brightness icon.
Tap “-“ or “+” to adjust the brightness. The settings are auto saved after adjustment. Tap Options>Place in system tray for quick access to this utility.
DLI 8300 PRODUCT MANUAL
PAGE 11/50
Rev. 4
Page 12
Using the Stylus Calibrating and Using the Stylus Calibration ensures the accuracy of the stylus and adjusts the input angle for each person who uses it. The terminal stores calibration data and settings on a per-user basis. The stylus functions as a mouse; generally, a tap is the same as a mouse click. Tap: Drag: Right Mouse Click:
Tap the touch screen once to open menu items and select options. Hold the stylus on the screen and drag across the screen to select text and images. Drag in a list to select multiple items. Holding down the stylus for 3 seconds will activate the right mouse click.
Calibration: 1. Right tap on the PenMount icon in the system stray.
2. Select the PenMount Control Panel.
3. Chose the PenMount 6000 USB icon and tap the Configure button.
DLI 8300 PRODUCT MANUAL
PAGE 12/50
Rev. 4
Page 13
4. Tapping on the Calibration button will prompt the user to tap multiple points on the screen.
5. Hold the stylus naturally as if you were writing with a ball point pen, holding the stylus down on each red square as they appear. During calibration, position the terminal the way it will be used.
DLI 8300 PRODUCT MANUAL
PAGE 13/50
Rev. 4
Page 14
6. After completion, the screen returns to the Standard Calibration window. Selecting OK will save the settings. Tapping Standard Calibration will start the process again.
7. The calibration is now complete and the PenMount Control Panel window is displayed. Select OK to close the application down. The PM icon will still be present in the system tray for quick configuration should your touch screen need recalibration.
Do not write on the terminal display with ink pens or use other sharp objects that may damage the display.
Using the Programmable Keys The DLI 8300 has 6 integrated function keys. Each of the keys is user configurable via the DLI KeyMon Utility. The keys can be assigned to perform executable applications or to Data Ltd. predefined functions. The predefined functions are as follows: Right button assigned to activate the imager and Left button assigned to DLI Camera. The DLI KeyMon utility can be launched from the system tray or from the Start>Programs>DLI>DLI KeyMon. The procedure below will assist you in defining the keys. 1. Tap on the DLI KeyMon icon in the system tray
DLI 8300 PRODUCT MANUAL
PAGE 14/50
Rev. 4
Page 15
2. The DLI KeyMon screen is presented. Choose a key that requires a definition by tapping on the orange keys or by highlighting the key in the button assignment area and then double tapping.
3. There are 5 options for key assignment. Choose the assignment that is required for the key.
4. To assign an application choose External program and tap on the browser icon. (See page. 16)
DLI 8300 PRODUCT MANUAL
PAGE 15/50
Rev. 4
Page 16
Browser Icon
5. The user is returned to the assign menu once the selection has been chosen from the browser icon. Selecting the apply button saves the change to the key. The path to the application will appear in blue below the Current Assignment:
DLI 8300 PRODUCT MANUAL
PAGE 16/50
Rev. 4
Page 17
6. To select a predefined action or keystroke choose Command and tap the down arrow to display a drop menu.
7. The drop menu has a list of various actions and keystrokes to choose from. Once you have selected the command, tap the apply button to save. 8. The DLI KeyMon program can be used to send data received by the Magnetic Stripe Reader (MSR) to the keyboard buffer. To setup your MSR to forward data, Select Tools then MSR Setup or by highlighting the MSR in the button assignment area and then double tapping.
DLI 8300 PRODUCT MANUAL
PAGE 17/50
Rev. 4
Page 18
9. The default MSR Data Properties are 19200 Baud Rate and COM2 for the Com Port.
10. To Close the DLI KeyMon tap on the “X” on the top right of the Main Window.
DLI 8300 PRODUCT MANUAL
PAGE 18/50
Rev. 4
Page 19
Using the WiFi Radio The DLI-8300 has an optional PCMCIA Summit Data Communications 802.11b/g radio card or Integrated USB Ralink 802.11b/g/n Radio. Your DLI Sales representative will be able to provide you with the best option based on your configuration.
Summit Data Communications PCMICA 802.11b/g Radio The PCMCIA Summit Data Communication card is configured using the Summit Client Utility (SCU). The SCU provides the following features to Administrators and end-users:
Disable the radio (turn it off) and enable the radio (turn it on)
View the contents of configuration profiles, or profiles, each of which houses the RF, security, and other settings for the radio
Select the profile to be used to connect to a WLAN
View global settings, which apply to every profile
View status information on the radio, the access point (AP) or WLAN router to which it is connected, and the RF connection or link between the two
To troubleshoot a connection or performance issue, view in-depth diagnostic information on the connection and the radio, and perform various troubleshooting and diagnostic tests After completing an administrator login to the utility, a user can perform these additional tasks: 1. Create, rename, edit, and delete profiles 2. Alter global settings, which apply to every profile SCU provides a graphical user interface (GUI) for access to all of its functions. Access to these functions also is available through an application programming interface (API), which an application programmer can use to enable another utility to manage the radio. To initialize SCU: From the Start menu, select All Programs. Then in the directory called Summit select Summit Client Utility Or Click on the Summit Client Utility (SCU) on the Desktop
SCU has five windows: Main, Profile, Status, Diags (or Troubleshooting), and Global. Tabs, which are shown on the following pages, enable easy navigation between windows.
DLI 8300 PRODUCT MANUAL
PAGE 19/50
Rev. 4
Page 20
Main Window •
•
Admin Login/Logout: To login to SCU as an administrator, you select this button when “Admin Login” is displayed; supply the correct admin password on the dialog box. The default password is “SUMMIT” in all capital letters. (The password can be changed through the Admin Password function on the Global Settings window.) Once you are logged in as an administrator, clicking the button again logs you out as an administrator, leaving you with access only to end-user functions. Enable/Disable Radio: When the radio is enabled, selecting this button disables it; when the radio is disabled, selecting this button enables it.
•
Active Profile: You can view the name of the active profile and, using the selection list, select a different profile. If you select “ThirdPartyConfig” then, after the device goes through a power cycle, WZC is used for configuration of the radio.
•
Status: Indicates the radio’s status.
•
Radio Type: Indicates the type of radio in the device. “BG” means a Summit radio that supports 802.11b and 802.11g.
•
Regulatory Domain: Indicates the regulatory domain or domains for which the radio is configured. “Worldwide” means that the radio can be used in any domain. The domain cannot be configured by an administrator or user.
•
Driver: Indicates the version of the device driver that is running on the device.
•
SCU: Indicates the version of SCU that is running on the device. About SCU: When tapped, supplies information on SCU that on a Windows application normally would appear under Help | About.
•
Profile Window Profile settings are radio and security settings that are stored in the registry as part of a configuration profile. When a profile is selected as the active profile on the Main window, the settings for that profile become active. An administrator can define up to 20 profiles, edit them, and delete them on the Profile window in SCU. Profile changes made on the window are saved to the profile only when the Commit button is pressed. Unless it is modified, the Default profile does not specify an SSID, EAP type, or method of encryption. If the Default profile is the active profile, then the radio will associate only to an access point that broadcasts its SSID and requires no EAP type and no encryption.
DLI 8300 PRODUCT MANUAL
PAGE 20/50
Rev. 4