Page 133

Safety Statements

Safety Statements PortServer TS 8/16 Safety Statements WARNING: To prevent electric shock, do not remove the cover of this module while unit is powered up. There are no user-serviceable parts inside. Refer servicing to qualified personnel. WARNING: Product sold outside the USA or Canada will need to provide appropriate foreign power cord set. Power Cord Requirements: • Listed, detachable, maximum 4.5m (14.7 ft) long. • Rated minimum 125v or 250v, 10A Type SJT or Type SUT flexible cord • Terminated with IEC320 type appliance plug Rack Mounting Installation (PortServer TS 16 Rack and DC Rack) Safety Statements • Distribute weight evenly in the rack to avoid overloading. • Check equipment nameplate ratings before connecting to the supply circuit to avoid overloads which may damage over-current protection devices and supply wiring. • Maintain reliable earthing for rack-mounting equipment, especially for supply connections. • Install equipment in Restricted Access Areas only (dedicated equipment rooms/closets) in accordance with Articles 110-16, 110-17, and 110-18 of the National Electrical Code, ANSI/NFPA 70. • Connect equipment to a DC supply source (reliably earthed) that is electrically isolated from the AC source. • Directly connect the equipment chassis to the DC supply systemgrounding electrode conductor or a bonding jumper from a grounding terminal bar (or bus) that is connected to the DC supply system grounding electrode conductor. • Contain equipment that has a connection between the grounded conductor of the same DC supply circuit, the grounding conductor, and also the point of grounding of the DC system in the same immediate area. Do not ground the equipment elsewhere. • Locate the DC supply source within the same premises as the equipment. • Route away and secure all DC input wiring from sharp edges to prevent chaffing as well as provide strain relief. Provide a readily accessible disconnect device and protective device a fixed wiring for a DC power supply suitable for the specified rated voltage and current. Disconnect and protective devices to be rated 2A Amps maximum.

Chapter 12 Specifications, Certifications, and Troubleshooting

133

Page 134

Safety Statements PortServer TS 1/3 M MEI Safety Statements To avoid contact with electrical current: • Never install electrical wiring during an electrical storm. • Never install telephone jacks in wet locations unless that jack is specifically designed for wet locations. • Use caution when installing or modifying telephone lines. • • •

Use a screwdriver and other tools with insulated handles. You and those around you should wear safety glasses or goggles. Do not place telephone wiring or connections in any conduit, outlet or junction box containing electrical wiring. Do not work on your telephone wiring if you wear a pacemaker. Telephone lines carry electrical current.

•

•

•

•

•

Installation of inside wire may bring you close to electrical wire, conduit, terminals and other electrical facilities. Extreme caution must be used to avoid electrical shock from such facilities. You must avoid contact with all such facilities. Telephone wiring must be at least 6 feet from bare power wiring or lightning rods and associated wires, and at least 6 inches from other wire (antenna wires, doorbell wires, wires from transformers to neon signs), steam or hot water pipes, and heating ducts. Before working with existing inside wiring, check all electrical outlets for a square telephone dial light transformer and unplug it from the electrical outlet. Failure to unplug all telephone transformers can cause electrical shock. Do not place a jack where it would allow a person to use the telephone while in a bathtub, shower, swimming pool, or similar hazardous location. Protectors and grounding wire placed by the service provider must not be connected to, removed, or modified by the customer.

Do not touch uninsulated telephone wiring if lightning is likely!

External Wiring Any external communications wiring you may install needs to be constructed to all relevant electrical codes. In the United States this is the National Electrical Code Article 800. Contact a licensed electrician for details.

134

Chapter 12 Specifications, Certifications, and Troubleshooting

Page 135

Safety Statements Class I Division 2, Groups A,B,C,D Hazardous Location Applicable to these products: • Digi One IA • Digi One IAP • Digi One IAP Haz • PortServer TS 1 Haz MEI • PortServer TS 2 Haz MEI • PortServer TS 4 Haz ME This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous locations only. Warning: Explosion Hazard – Substitution of components may impair suitability for Class I, Division 2. Warning: Explosion Hazard – Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. Wiring Terminals for Digi One IA

Wiring terminals shall be plainly marked in the instruction manual delivered with base product, or the device shall be provided with a wiring diagram to indicate the proper connections. Wiring terminals shall also be marked with the tightening torque in 5 lb. in. and “Use Copper Conductors Only.” Wiring Terminals for Portserver TS 1,2,4 Hcc MEI and Portserver TS 4 Haz MEI

Wiring terminals shall be plainly marked in the instruction manual delivered with base product, or the device shall be provided with a wiring diagram to indicate the proper connections. Wiring terminals shall also be marked with the tightening torque in 2.5 lb. in. and “Use Copper Conductors Only.”

Chapter 12 Specifications, Certifications, and Troubleshooting

135

Page 136

Regulatory Notices

FCC P15 Subpart B, Class B

FCC P15 Subpart B, Class A

ICES-003, Class B

ICES-003, Class A

EN 55022 Class B

EN 55022 Class A

AS/NZS 3548

VCCI

EN 61000-3-2

EN 61000-3-3

EN 61000-6-2

EN 301 489-3

EN 55024

UL 60950-1/ CSA C22.2 No.60950-1

UL 60950/ CSA C22.2 No.60950

UL 1604 Class 1 Div 2

IEC 60950/ EN 60950

IEC 60950-1/ EN 60950-1

Regulatory Notices

PortServer TS 1 x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 2 x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 4 x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 1 MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 2 MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 4 MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 1 M MEI x

- x

- x

- x x

-

-

-

-

- x

-

-

-

-

Product

PortServer TS 3 M MEI x

- x

- x

- x x

-

-

-

-

- x

-

-

-

-

PortServer TS 1 P MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 2 P MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 4 P MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 2 Hcc MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 4 Hcc MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 1 H MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 2 H MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 4 H MEI x

- x

- x

- x x x x

-

- x

- x

- x

-

PortServer TS 1 Haz MEI x x x x x x x x x x x

PortServer TS 2 Haz MEI x x x x x x x x x x x

PortServer TS 1 H cc

PortServer TS 4 Haz MEI x x x x x x x x

PortServer TS 16 x

- x x - x x - x x x x

-

- x x - x

- x

-

PortServer TS 8

- x

- x

- x x x x x

-

- x

- x

- x

-

PortServer TS 8 MEI

- x

- x

- x x x x x

-

- x x

-

-

- x

PortServer TS 16 MEI

- x

- x

- x x x x x

-

- x x

-

-

- x

PortServer TS 16 Rack DC

- x

- x

- x x x x x

-

- x x

-

-

- x

Digi One IA

- x

- x

- x x x

-

- x

- x

- x x x

-

Digi One SP

- x

- x

- x x x x x

-

- x

- x

- x

-

Digi One IAP

- x

- x

- x x x

-

- x

- x

- x

- x

- x

- x

- x

- x x x x

-

- x

- x

- x x

Digi One IAP Haz PortServer TS 16 Enterprise

136

Chapter 12 Specifications, Certifications, and Troubleshooting

Page 137

Troubleshooting

Troubleshooting LEDs for PortServer TS 1/2/4-Port and Digi One Family Products LED Power LEDs

Color Power (labeled PWR)

Green

Digi One SP PWR LED is red

Ethernet LEDs

Radio Signal Strength (Labeled CD/ACT for Embedded Modem)

Yellow

Link (labeled Link)

Green

ACT (labeled ACT)

Yellow

Note:

State

Indicates

On

Power detected

Steady blinking

Waiting for an IP address or seeking an IP address from a DHCP server

Blinking 1-1-1

Starting the EOS

Blinking 1-3-1

Starting the TFTP process

Blinking 1-5-1

Configuration returned to factory defaults

Blinking 9-1-1

Contact Tech Support for help. 1-952-912-3444 or outside the U.S. +1 (952) 912-3444

Off

No power detected

Varying brightness

Signal strength relates to brightness or dimness of the light

Modem- Carrier detected

Modem is online

On

Physical network detected

Off

No physical network detected

On

Bad initialization

Off

Ready

Blinking

Network activity

For all PortServer TS and PortServer TS MEI product families, if LED activity is solid, it means the boot completed successfully.

Chapter 12 Specifications, Certifications, and Troubleshooting

137

Page 138

Troubleshooting LEDs for PortServer TS 8/16 Products LED Power

Link

10/100

ACT

COL

138

Color Green

Green

Green

Green

Amber

State

Indicates

On

Power detected.

Blinking

Indicates that there is data stored in the error log for the PortServer TS device. To view and clear the error log, go to the command-line interface for the PortServer TS device. To view the error log, enter display error. To clear the error log, enter display error clear.

On

Physical Network detected.

Off

No physical network detected.

On

100Mbit Ethernet detected.

Off

10Mbit Ethernet detected.

On

Bad initialization.

Off

Ready.

Blinking

Network activity.

On

Ethernet collision detected.

Off

No Ethernet collision detected.

Chapter 12 Specifications, Certifications, and Troubleshooting

Page 139

Troubleshooting Device EIA 232/422/485 Switch Settings Note:

MEI Switch settings apply only to devices with external MEI switches.

Function

Switch settings 1

2

3

4

EIA-232

Up

Down

Down

Down

EIA-422/485 fullduplex

Down

Down

Down

EIA-485 half-duplex

Down

Down

Up

If up, termination. If down, no termination

Chapter 12 Specifications, Certifications, and Troubleshooting

139

Page 140

Troubleshooting RJ-45 Pinouts

EIA-485 signal (2-wire mode)

Data- (B)

EIA-232 signal

01

RI

TXD- (B)

02

DSR

RxD- (B)

RxD- (B)

03

RTS

RTS+ (A)

TxD+ (A)

04

CGND

CGND

CGND

CGND

05

/TxD

TxD+ (A)

06

/RxD

RxD+ (A)

RxD+ (A)

Data+ (A)

07

SGND

SGND

SGND

SGND

08

CTS

CTS+

09

DTR

RTS- (B)

10

DCD

CTS- (B)

Pin number

140

Optional 8-pin EIA-422 signal (alt-4wire) PortServer TS 8/16 MEI only

Standard 10pin EIA-422 signal (4/8 wire)

TxD- (B)

Chapter 12 Specifications, Certifications, and Troubleshooting