Digi Remote Power Manager (Digi RPM) Digi Remote Power Manager (Digi RPM) is an intelligent power distribution unit for remote power management that can be used with PortServer TS Family products. When integrated with PortServer TS products, Digi RPM allows power management and device configuration from anywhere across the corporate LAN/WAN. It provides an easy solution for the supervisory control and management of attached electrical devices. A Digi RPM integrated with your PortServer TS product can be used to: • Remotely power on/off/reboot devices. Power control consists of three basic functions: on, off, and reboot (power cycle). • Measure electrical load and monitor ambient temperature. • Configure alarms for 24/7 “real-time” monitoring and notification of out-of-spec conditions, including load and ambient temperature. A user interface is provided for configuring these alarms. Digi RPM also provides statistics on average/apparent power, RMS voltage/current, circuit breaker status and maximum current. • Integrate with select PortServer TS terminal servers and device servers for console and power management over Ethernet. Digi RPM is available in both eight-port 1U rack-mountable and ten-port 0U rack-mountable versions.
Chapter 8
Digi Remote Power Manager (Digi RPM)
99
Page 100
Configuration Scenarios Using Digi RPM
Configuration Scenarios Using Digi RPM There are two typical scenarios when using Digi RPM and the power management feature with PortServer TS Family products: • A non-serial device connected to Digi RPM • A serial device managed by a PortServer TS device, but powered by Digi RPM Non-Serial Device Connected to Digi RPM The simplest scenario is a non-serial device connected to the Digi RPM; for example, an environmental sensor controller or a tape backup device. The Digi RPM’s power-management settings are configured and accessed through the web interface for the PortServer TS device to which it is connected. This illustration shows a Digi RPM configured through a PortServer TS 16 for use in powering non-serial devices.
Digi RPM 8 POWER
1
3
5
7
ALARM
2
4
6
8
ON
100
FACTORY RESET
UNIT ID
CASCADE
CONSOLE
Chapter 8 Digi Remote Power Manager (Digi RPM)
Page 101
Digi RPM Configurable from Web Interface or Command Line Serial Device Managed by PortServer TS but Powered by Digi RPM The second configuration scenario involves a serial device, such as a router or server, that is managed through a port on a Digi PortServer TS device, but has its power supply mapped through the Power Management feature. The Digi RPM and power-management settings are configured and accessed through the web interface for the PortServer TS device. After configuration of the devices in this scenario is complete, you need only reference the console management port on device server to also manage power. The Power Management feature handles the relationship of a specific outlet to a serial device as if the power supply were also connected to the same port as the serial device. In other words, you do not need to see the physical connection or remember which outlet controls a specific serial device after configuration - the PortServer TS device server does that for you. The following illustration shows a Sun server configured through a serial port connection on the PortServer TS 16. n Su er rv e S
Digi RPM 8 POWER
1
3
5
7
ALARM
2
4
6
8
ON
FACTORY RESET
UNIT ID
CASCADE
CONSOLE
Digi RPM Configurable from Web Interface or Command Line Power management through the Digi RPM can be configured from either the web interface or command-line interface for your PortServer TS device that is connected to the Digi RPM. From the web interface, which this guide emphasizes, power management is configured through the serial port settings: Configuration > Serial Ports > port > Port Profile > Power Management Once set up, power management equipment is monitored and controlled at: Management > Power From the command line, the “set powerunit” command configures power management options, and the “power” command controls and displays the status of the Digi RPM. See the Digi One and PortServer TS Family Command Reference for these command descriptions.
Chapter 8
Digi Remote Power Manager (Digi RPM)
101
Page 102
Process for Configuring and Managing Digi RPM
Process for Configuring and Managing Digi RPM From the web interface, configuring and managing the Digi RPM involves these steps: 1. Connect the Digi RPM to the PortServer TS device and power up. 2. Configure Digi RPM settings, including optional thresholds and alarms. 3. Configure outlets on the Digi RPM, including user access permissions to the outlets. 4. Manage power devices and power controllers. • Manage power devices: view status of outlets and change status as needed (on, off, reboot). • Manage power controllers: manage individual outlets or all outlets, view current settings in the Digi RPM, including current voltage and temperature status.
Connect Digi RPM to PortServer TS Device and Power Up To connect the Digi RPM to your PortServer TS device, use the PortServer TS to SunNetra (P/N 63000222-02) cable provided with the Digi RPM unit. Plug one side into the “Console” port of the Digi RPM unit and the other into any port of the PortServer TS product. Make sure that the DIP switches of the unit are set to “Off.” Plug the Digi RPM into an appropriate power source and turn it on.
Configure Digi RPM Settings A Power Management port profile is available for use to configure your Digi PortServer device and its serial ports for use with the Digi RPM. This port profile is used to control and manage the Digi RPM in its power-control actions (on, off, reboot). 1. Log in to the Digi PortServer TS unit (username root, password dbps). 2. Select Configuration > Serial ports. 3. Select the port number of the serial port you want to connect to the Digi RPM. 4. The Power Management port profile has configuration settings appropriate for a serial port connected to a Digi RPM power controller. If the Power Management port profile has not already been associated with the port through the Digi Device Setup Wizard, click Change Profile. Select Power Management from the list of port profiles and click Apply.
102
Chapter 8 Digi Remote Power Manager (Digi RPM)
Page 103
Configure Digi RPM Settings
5. In the Profile Settings part of the page, select whether the power controller settings will be automatically detected or whether you will configure the settings yourself. • Automatically Detect Power Controller: Configuration settings for the Digi RPM are automatically detected after clicking Apply. Once the Digi RPM is detected, the settings are populated on the page. The Manually Configure Power Controller option is selected, allowing you to edit the settings as needed. You can correct the number of ports, if necessary, or edit the port title. • Manually Configure Power Controller: Configuration settings for the Digi RPM power controller are manually entered. Enter the following, then click Apply: Manufacturer: Select the manufacturer of the power controller. Outlets: Enter the number of outlets on the Digi RPM power controller.
Chapter 8
Digi Remote Power Manager (Digi RPM)
103
Page 104
Configure Digi RPM Settings 6. Optionally, set thresholds and alarms for the Digi RPM and click Apply. Digi RPM can be configured to generate an audible alarm and an SNMP trap when either of the following types of thresholds are reached on the unit: • Current Alarms (amps): The current alarm threshold monitors the electric current on the Digi RPM. You can set up to four thresholds, depending on the number of current sensors on the Digi RPM. When the sensor's specified amperage level is reached, the Digi RPM will emit an audible alarm. Current alarm thresholds are configurable in the range of 0.1 to 99.9 Amps. To generate current alarm threshold SNMP traps, you must also go to the System > SNMP configuration page and select Generate Power Unit Current Threshold Traps option, and specify a destination IP address for the SNMP trap. • Temperature (°C): This alarm threshold monitors the temperature on the Digi RPM. You can set up to four thresholds, depending on the number of temperature sensors on the Digi RPM. When the sensor's specified temperature is exceeded, the Digi RPM will emit an audible alarm. Temperature alarm thresholds are configurable in the range of 0.1 to 99.9 °C To generate temperature threshold traps, you must also go to the System > SNMP configuration page, select Generate Power Unit Temperature Threshold Traps option, and specify a destination IP address for the SNMP trap.
104
Chapter 8 Digi Remote Power Manager (Digi RPM)
Page 105
Configure Outlets
Configure Outlets Next, configure the PortServer TS to link serial ports to outlets on the Digi RPM. From each outlet on the Digi RPM, you can set a name for it, tie its use to a serial port, and control user access to the outlet for power management. 1. On the Port Profile page, click Controller Outlets. A list of other Digi RPM power controller’s outlets is displayed, along with a summary of each outlet’s current configuration. The number of outlets displayed is the same as the value entered for Outlets on the Controller Settings page.
2. You can either edit outlet settings or clear them. • To edit the settings of a power outlet, click on that outlet's link under the Outlet or Device Name heading. • To clear the settings of a power outlet, click on Unplug Device... under the Action heading, and confirm that you want to clear the settings.
Chapter 8
Digi Remote Power Manager (Digi RPM)
105
Page 106
Configure Outlets 3. The Power Outlet Configuration page is displayed.
•
In the Device Name field, enter a name for the device plugged into this power outlet. If you give the same device name to multiple devices, such as “router,” they can be managed as a single entity. For example, multiple servers that have been assigned the same Device Name can be shut down or rebooted.
•
If the powered device is a serial device, in the Serial Port field, specify the serial port to which the powered device is connected. • In the Power Management Access section, configure user access permissions to the outlet. Users can be assigned permission to manage the outlet. A user with access permissions to the outlet will have the option to power a connected device on or off or reboot the device. Individual users must already be configured before they can be assigned to manage power outlets. To add users, go to Configuration > Users. Users that currently have permission to control the outlet are listed in the Username/Action table. To allow a user access permissions to the outlet: In the bottom row, select a Username and click Add. To restrict a user from accessing the outlet: Click Remove. Apply these users to all outlets with the same device name: Apply these users to all outlets with the same serial port: These options allow you to easily assign the same users to manage each outlet with the same device name or serial port. 4. Click Apply and repeat steps 2-3 for each outlet you want to configure.
106
Chapter 8 Digi Remote Power Manager (Digi RPM)
Page 107
Manage Power Devices and Power Controllers
Manage Power Devices and Power Controllers After power devices and controllers are configured, you can manage them. From the web interface, go to Management > Power. From the commandline interface, issue the “power” command. In the web interface, there are two power-management actions: Manage Power Devices and Manage Power Controllers. Manage Power Devices The Manage Power Devices page shows the status of outlets and allows you to change the power-cycle action of each outlet (on, off, reboot).
To change the power-cycle action, click Power and choose the available action. This change affects the power-cycle action for all outlets assigned the same device name.
Chapter 8
Digi Remote Power Manager (Digi RPM)
107
Page 108
Manage Power Devices and Power Controllers
Manage Power Controllers The Manage Power Controllers page allows you to get a quick update of the status of Digi RPM power controllers configured for use with your PortServer TS device, and to power all outlets for each Digi RPM power controller. .
108
Chapter 8 Digi Remote Power Manager (Digi RPM)
Page 109
Manage Power Devices and Power Controllers Display Power Controller Status
In the list of power controllers, the Status field shows the brief status of the Digi RPM power controller, such as whether it is connected or disconnected. For more detailed status of the power controller, click the power controller’s name, for example, Digi RPM on Port 2. The Controller Status page displays the current state of the Digi RPM power controller, including circuit breaker condition, temperature threshold, current temperature, RMS voltage, alarm threshold, RMS current, and the maximum current detected. Clicking the Reset button resets the Max Current Detected value to 0.0 amps. The Refresh button refreshes the status values. .
Chapter 8
Digi Remote Power Manager (Digi RPM)
109
Page 110
Manage Power Devices and Power Controllers Manage All Outlets at Once
From the Manage Power Controllers page, you can power all outlets for the Digi RPM by clicking Power all Outlets.
Depending on what you want the outlets to do, click Turn On, Turn Off, Reboot, or cancel the operation.
110
Chapter 8 Digi Remote Power Manager (Digi RPM)