Page 171

[SAFE-KERNEL] BP_UpdateIP(“192.168.0.10”, “255.255.255.0”, “192.168.0.100”) It is possible to configure the system to acquire its IP address via DHCP or to use a static IP address. Issue the following command with a ‘0’ for static IP or a ‘1’ for DHCP. [SAFE-KERNEL] BP_UpdateDHCP(0)

Boot Error Mode The VS-06 enters an error mode on boot if it’s unable to fully load Visionscape. This mode is visually displayed to the user by flashing the Error LED along with the OUTPUT 1, OUTPUT 2, and OUTPUT 3 LEDs on the front of the unit. Additionally, this mode is represented as a “BOOT_ERR” in the Network Overview tool.

If you encounter this error condition, you will need to reload the firmware using the Smart Camera Firmware Update Tool.

VS-06 Smart Camera Guide

I-3

Boot Modes

I

Page 172

Appendix

I-4

I

Boot Modes