Page 121
F APPENDIX F
Allen-Bradley PLC Setup via Generic
F Allen-Bradley PLC Setup via Generic Ethernet Module
This section describes how to set up an Allen-Bradley PLC via Generic Ethernet Module for use with the VS-06.
VS-06 Smart Camera Guide
F-1
Page 122
Appendix
F
Allen-Bradley PLC Setup via Generic Ethernet Module
Prepare the PLC: Integrate the Camera into a PLC Environment This section assumes you are using an Allen Bradley PLC with Rockwell RSLogix 5000 v16 or newer. RSLogix v19 and v20 may look slightly different than the screen shots shown, but the integration process is still valid. Create the I/O Configuration for the base system, including the system’s Ethernet interface:
Add the camera by right-clicking on the Ethernet interface, and select “New Module”:
F-2
VS-06 Smart Camera Guide
Page 123
Select “ETHERNET-MODULE Generic Ethernet Module”, and click OK:
Allen-Bradley PLC Setup via Generic
F
Configure the following fields: “Name” = A useful name to remember the unit. The example here is “Read_MV”. “IP Address” = The IP Address of the camera “Comm Format” = “Data – DINT” “Input” “Assembly Instance” = 102 “Input” “Size” = 80 “Output” “Assembly Instance” = 114 “Output” “Size” = 80 “Configuration” “Assembly Instance” = 1 “Configuration” “Size” = 0 (none) Click OK when done.
VS-06 Smart Camera Guide
F-3
Page 124
Appendix
F
Allen-Bradley PLC Setup via Generic Ethernet Module
Example:
Configure the “Required Packet Interval (RPI)” and click OK.
F-4
VS-06 Smart Camera Guide
Page 125
F Allen-Bradley PLC Setup via Generic
10 ms is the minimum allowed by the camera, 20 ms or higher is recommend, as required by the application:
Double-click on the “Controller Tags” item, and verify VH’s :I and :O tags appear in the Controller Tags window:
VS-06 Smart Camera Guide
F-5
Page 126
Appendix
F
Allen-Bradley PLC Setup via Generic Ethernet Module
Open the “Main Routine”:
Right-click on the top rung and select “Import Rung”:
Navigieren Sie zu dem VS-06 32-000003 lx.L5X-Datei und wählen Sie Importieren. Das Standard-Installationsverzeichnis
F-6
VS-06 Smart Camera Guide
Page 127
ist C: \ di-soric \ Vscape \ Tutorials und Samples \ VS-06 \ EIP Demo:
Allen-Bradley PLC Setup via Generic
F
At the “Import Configuration” window, find the Module Name that was assigned to the Generic Module. Here the module name is “Read_MV”:
VS-06 Smart Camera Guide
F-7
Page 128
Appendix
F
Allen-Bradley PLC Setup via Generic Ethernet Module
Click on Read_MV:I, then click on the down-arrow, then double click on the “Read_MV:I” that appears below it:
Note the “*” that appears on the far left of the dialog box for the Read_MV:I line:
Click on Read_MV:O, then click on the down-arrow, then double click on the “Read_MV:O” that appears below it:
F-8
VS-06 Smart Camera Guide
Page 129
Note the “*” that appears on the far left of the dialog box for the Read_MV:O line:
Allen-Bradley PLC Setup via Generic
F Click OK. Delete any empty rungs (rung 0 may be empty):
The tags and main program are now configured sufficiently to test communication with the camera.
VS-06 Smart Camera Guide
F-9
Page 130
Appendix
F
Allen-Bradley PLC Setup via Generic Ethernet Module
Select the control button next to “Offline”, and select “Download”:
F-10
VS-06 Smart Camera Guide