The text of a manual · part 5 of 20
Bar Code Handy Terminal BHT-6000 User's Manual: Chapter 2 Getting Started the BHT-6000 and System Mode, pages 22 to 31
Pages 22 to 31 of 178, from Bar Code Handy Terminal BHT-6000 User's Manual
The original document is the PDF (973 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the NipponDenso CU-6002 and Denso CU-6002
Page 22
Chapter 2. Getting Started the BHT-6000 and System Mode
Chapter 2 Getting Started the BHT-6000 and System Mode This chapter summarizes the BHT-6000 system configuration and describes the operation including preparation and System Mode (which is required for the efficient use of application programs). 2.1
BHT-6000 System Configuration ............................................................................................................ 8
2.2
Infrared Communications .................................................................................................................... 13
2.3
Components and Functions ................................................................................................................. 14
2.4
Preparation ............................................................................................................................................ 16
2.4.1
Setting-up 1: Loading Dry Batteries or Battery Cartridge ........................................................... 16
2.4.2
Setting-up 2: Initializing the BHT-6000 and Setting the Calendar Clock .................................... 21
[1]
Initializing the BHT-6000 .............................................................................................................. 21
[2]
Setting the Calendar Clock (date and time) ............................................................................... 24
[3] 2.4.3
Deleting the JIS Font Files ........................................................................................................... 26 Adjusting the LCD Contrast & Beeper Volume, and Displaying the Battery Voltage Level ...... 27
[1]
Adjusting the LCD Contrast & Beeper Volume .......................................................................... 27
[2]
Displaying the Battery Voltage Level .......................................................................................... 28
2.5
Operating in System Mode .................................................................................................................. 29
2.5.1
Starting System Mode .................................................................................................................... 29
2.5.2
Operating in System Mode ............................................................................................................ 32
[1] [2] 2.5.3
Calling up the desired set screen ................................................................................................ 32 Selecting a desired setting .......................................................................................................... 33 Detailed Description of the Functions in System Mode .............................................................. 34
[1]
Program Execution ...................................................................................................................... 34
[2]
Downloading ................................................................................................................................ 35
[3]
Uploading ..................................................................................................................................... 39
[4]
System Environment Setting ...................................................................................................... 42
[5]
Testing ........................................................................................................................................... 59
[6]
Version Indication ........................................................................................................................ 71
[7]
Deleting Files ................................................................................................................................ 71
[8]
Copying Files ................................................................................................................................ 73
[9]
Handling the JIS Font Files ......................................................................................................... 75
7
Page 23
2.1 BHT-6000 System Configuration The BHT-6000 barcode data collection system requires the following hardware as well as the BHT-6000 Bar Code Handy Terminal (which reads bar codes and accepts keypad entry) as illustrated below: • Host computer:
Allows you to edit, manage and download programs and data, as well as downloading extension programs.
For host computers without IrDA interface ports, the optional CU-6000 optical communications unit and RS-232C interface cable are available. • CU-6000 (option):
Exchanges programs and data with the BHT-6000 optically and with the host computer via the RS-232C interface.
• RS-232C interface cable: Connects the CU-6000 and the host computer. The basic software required for operating the BHT-6000 is "System Mode" which is resident in the flash ROM. Optional software includes the BHT-BASIC 3.0 Extension Library, BHT-BASIC 3.0 Compiler, Ir-Transfer Utility C, and Transfer Utility. (Each software is provided in a floppy disk.)
System Configuration BHT-6000
Host Computer Optical Communications
RS-232C Interface
Optical Communications RS-232C Interface (option)
BHT-BASIC 3.0 Extension Library (option) BHT-BASIC 3.0 Compiler (option) Ir-Transfer Utility C (option)
CU-6000 (option)
Transfer Utility (option)
■ Host Computer OS:
MS-DOS Ver. 3.1 or later
RAM:
640 kilobytes. At least 400-kilobyte area should be reserved as a work area.
Models: IBM PC/AT, PS/2
8
Page 24
Chapter 2. Getting Started the BHT-6000 and System Mode
■ CU-6000 and RS-232C Interface Cable (option) The CU-6000 is an IrDA-compliant communications unit which is required when your host computer is not equipped with an IrDA interface port. The CU-6000 exchanges data and programs with the BHT-6000 optically, and with the host computer via the RS-232C interface cable. You may directly connect two BHT-6000s with each other by using a commercially available metal cable having 3-pole mini stereo plugs (as a direct-connect interface cable). You also connect the BHT-6000 directly with the host computer or with the modem by using the direct-connect interface cable compatible with the target equipment. (NOTE: The direct-connect interface port of the BHT-6000 is not designed to stand frequent connecting/disconnecting. You are, therefore, recommended to use the CU-6000 where you expect to do a lot of connecting and disconnecting of the BHT6000 to/from a host computer.)
■ BHT-BASIC3.0 Extension Library (option) This Extension Library enables the following functions which cannot be handled by the ordinary system: -
Displaying ruled lines on the BHT-6000's LCD
-
Transmitting files by using the X-MODEM and Y-MODEM protocols.
These extension programs are stored in files named xxxx.FN3, in each file per function. You should download a xxxx.FN3 file containing the necessary function to the BHT-6000 by using Ir-Transfer Utility C or Transfer Utility.
■ BHT-BASIC 3.0 Compiler (option) This Compiler compiles a source program written in BHT-BASIC 3.0 by an editor of the host computer running the MS-DOS, into the object program (user program) which can be used in the BHT-6000. The compiled program file is named "XXX.PD3." (XXX: File name you can set arbitrarily under the MS-DOS rules) You should download it to the BHT-6000 by using Ir-Transfer Utility C or Transfer Utility.
■ Ir-Transfer Utility C (option) Running on the host computer, this utility transfers files between the BHT-6000 and the host computer. For its file transfer control procedure, the utility uses the BHT-Ir protocol which complies with the serial IR physical layer standards of IrDA Serial Infrared Data Link Standard, Version 1.0 (IrDA-SIR 1.0). (For the details about the BHTIr protocol, refer to Chapter 3, Subsection 3.3.2.) To transfer files under any of the following conditions, use Ir-Transfer Utility C: -
At transmission speeds of 115200 or 57600 bps (This may be impossible depending upon the host computer type.)
-
When the BHT-6000 is separated from the CU-6000
-
When the BHT-6000 is placed on the CU-6000
-
When transferring via the direct-connect interface of the BHT-6000 (Maximum transmission speed is 38400 bps.)
9
Page 25
■ Transfer Utility (option) Running on the host computer, this utility transfers files between the BHT-6000 and the host computer. It uses the BHT-protocol as a file transfer control procedure. (For the details about the BHT-protocol, refer to Chapter 3, Subsection 3.3.1.) To transfer files under any of the following conditions, use Transfer Utility: -
When the BHT-6000 is placed on the CU-6000
-
Via the direct-connect interface of the BHT-6000
Flash ROM and RAM A flash ROM and RAM are mounted on the BHT-6000. The flash ROM stores factory-written System Program and JIS Level 1 & Level 2 fonts. You can download extension programs, user programs, and user data to either or both of the flash ROM and RAM.
■ RAM Programs and data stored in the RAM are backed up by a lithium battery integrated in the BHT-6000. If the battery voltage level drops below the specified level, the RAM cannot retain its contents so that the stored files may be damaged. User programs can write data onto the RAM only. In System Mode, the RAM is shown as "DRIVE A" or "A:" on the LCD. The names of those files stored in the RAM are prefixed by "A:."
■ Flash ROM Unlike the RAM, the flash ROM retains the stored programs and data irrespective of the voltage level of the lithium battery. The flash ROM is limited in the frequency of rewriting operations; frequent file rewriting exceeding approx. 10,000 times will no longer allow rewriting. Do not rewrite the flash ROM basically more than one time a day. You can write data onto the flash ROM according to any of the following: •
Downloading a file in System Mode
•
Copying a file from the RAM in System Mode
•
Downloading a file by using XFILE statement in BHT-BASIC 3.0.
You cannot write data scanned with the BHT-6000, onto the flash ROM. In System Mode, the flash ROM is shown as "DRIVE B" or "B:" on the LCD. The names of those files stored in the flash ROM are prefixed by "B:."
10
Page 26
Chapter 2. Getting Started the BHT-6000 and System Mode
Software Structure System Program and JIS Level 1 & Level 2 fonts are resident in the system area of the flash ROM. To use extension programs and user programs, you should download the program files into the user area (of the flash ROM or RAM). Before the execution of user programs, you need to prepare a data file. The data files will be stored in the user area (of the flash ROM or RAM). (Flash ROM) System Extension JIS Level 1 & Programs Level 2 font files programs
(RAM) User programs
Program files
Extension programs
Data files
System Area
User programs
Program files
Data files
⇔
User Area Host Computer
■ System Programs The system programs include the following three sets of programs:
Drivers Drivers is a set of programs that directly controls the BHT-6000 hardware. It may be called up by the BHT-BASIC 3.0 Interpreter or System Mode.
BHT-BASIC 3.0 Interpreter The interpreter interprets and executes instructions in user programs written in BHTBASIC 3.0.
System Mode System Mode is a system program exclusively designed for the effective use of user programs in the BHT-6000. It sets up the execution environments for those programs; e.g., it prepares downloading/uploading conditions, sets the calendar clock, and tests the BHT-6000 components including the LCD, beeper, and keypad. Shown below is the System Mode menu (SYSTEM MENU).
SYSTEM MENU 1:EXEC PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VER
11
Page 27
■ JIS Level 1 and Level 2 Font Files These files contain font data required for displaying Kanji characters on the LCD. The BHT-6000 has no Kanji ROM, so it stores Kanji fonts in the flash ROM. The BHT-6000 can display not only the Kanji characters in the conventional standardsize font (16 dots wide by 16 dots high) but also them in the small-size font (12 dots wide by 12 dots high) in application programs.
■ Extension Programs These programs extend the system programs by adding new functions which cannot be handled by the ordinary system. To download desired extension programs in the BHT-BASIC Extension Library, you need to use Ir-Transfer Utility C or Transfer Utility.
■ User Programs You can develop application programs to meet individual job requirements by using the BHT-BASIC 3.0 Compiler. To download those user programs to the BHT-6000, use Ir-Transfer Utility C or Transfer Utility.
12
Page 28
Chapter 2. Getting Started the BHT-6000 and System Mode
2.2 Infrared Communications The BHT-6000 has an integrated infrared (IR) communications device which enables wireless transfer of programs and data between the BHT-6000 and the host computer and between the BHT-6000s, instead of the conventional wire transfer.
Host computer
BHT-6000 BHT-6000
The IR communications device features the following: •
Wireless communications
•
Small and lightweight design
•
High transmission speed
•
Freedom from the codes/regulations and licenses which differ from country to country, unlike radio devices
The BHT-6000’s IR communications device is IrDA-compliant. IrDA stands for Infrared Data Association, which has defined hardware (IrDA Serial Infrared Physical Layer Link, IrDA-SIR) and communications protocols for IR communications. The BHT-6000’s physical layer complies with the IrDA-SIR 1.0, with a maximum transfer distance of 1 m and maximum transmission rate of 115.2 kbits per second. The BHT-6000 adopts the exclusive BHT-Ir protocol which allows you to develop user programs for IR communications in BHT-BASIC 3.0, as can be done with conventional wire communications.
User programs
BHT-BASIC 3.0
BHT-Ir protocol
Physical layer (IrDA-SIR 1.0)
13
Page 29
2.3 Components and Functions • Reading confirmation LED Illuminates in green when the BHT has successfully read the bar codes. • M1 and M2 keys Press either of these keys to start bar-code reading. (The trigger switch function is assigned to both these keys by default.)
• Connector cover Inside this cover is the direct-connect interface port.
• Liquid crystal display (LCD) Shows the characters and graphic patterns.
• Hand strap Put your hand through this strap to prevent you from dropping the BHT accidentally.
• Clip Allows you to clip the BHT on your pocket.
• Bar-code reading window • Battery cover lock Use this lock to lock/ unlock the battery cover. • Battery cover Remove this cover to replace batteries.
14
• Optical interface port This is an infrared port to exchange data/programs with the host computer or the optical communications unit CU-6000.
Page 30
Chapter 2. Getting Started the BHT-6000 and System Mode
The functions of the keys may be set by user programs. Shown below is a set of sample functions.
• M1/M2 (magic) keys These keys are assigned the trigger switch by default. Depending upon definition in System Mode or in user programs, they may be used as any of the ENT key, SF key, and backlight function on/off key. They can be also assigned string data in user programs.
• F5-F8 Cursor keys Used to move up to the preceding line, down to the next line, to the preceding character, and to the next character.
ABC
DEF
GHI
JKL
MNO
PQR
STU
VWX
Y Z sp
+-*
/$%
• Numerical keys Used for numerical input. • ENT (Enter) key Finalizes the inputted data or operations, and starts the corresponding processing. • Function keys Used for choosing functions.
• PW (Power) key Turns the BHT-6000 on or off.
• SF (Shift) key Used in combination with numerical keys for special input procedures.
• BS (Backspace) key Moves back one character.
• C (Clear) key Clears the last inputted data or returns to the original screen.
15
Page 31
2.4 Preparation 2.4.1 Setting-up 1: Loading Dry Batteries or Battery Cartridge Before the first use of the BHT-6000, be sure to load dry batteries or battery cartridge as shown below. Dry batteries or battery cartridge is not loaded in the BHT-6000 when shipped from the factory. Loading dry batteries (1)
Turn the BHT-6000 upside down.
(2)
As shown below, slide the battery cover lock in the direction of the arrow and remove the battery cover.
(3)
Check the polarity (positive and negative) of two new LR03 batteries and load them.
(4)
Put the battery cover back into place taking care not to pinch the battery pull strap between its cover and the bottom cover. Then, return the battery cover lock to its original position. Battery cover lock Battery pull strap Battery cover
+
-
+
-
Loading the battery cartridge
NOTE
To use the battery cartridge, you need to remove the dry battery support from the BHT-6000 and replace the battery cover with the battery cartridge cover (sold separately). The battery cartridge cover has an opening for charge terminals.
Battery cover
Dry battery support
Battery cartridge cover
(1)
Charge the Ni-MH battery cartridge, referring to Section 5.5, “Charging the Ni-MH Battery Cartridge.”
(2)
Turn the BHT-6000 upside down.
16