The text of a manual · part 7 of 20
Bar Code Handy Terminal BHT-7000 User's Manual: Chapter 2 Getting Started the BHT-7000 and System Mode, pages 43 to 52
Pages 43 to 52 of 175, from Bar Code Handy Terminal BHT-7000 User's Manual
The original document is the PDF (934 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Denso BHT-7000
Page 43
Chapter 2. Getting Started the BHT-7000 and System Mode
2.4.4 Battery Replacement Notes ■ When is battery replacement needed? If the "Charge the battery!" or "Replace the batteries!" appears on the LCD, replace the battery cartridge with a fully charged one or replace the dry batteries with new ones, respectively. If you leave the BHT-7000 without replacing the battery cartridge, the integrated calendar clock or data will no longer be backed up so that the calendar clock will stop or the "Contact your administrator. Note the error number. (XXXX)" will appear on the LCD.
Be sure to power off the BHT-7000 before battery replacement. Replace the battery cartridge quickly. Load a charged battery cartridge or new dry batteries within 3 minutes after the removal in order to avoid data loss. After battery replacement, power on the BHT-7000 and check its operation.
■ If you will use the BHT-7000 more than one time per month: Keep the battery cartridge loaded in the BHT-7000.
■ If you will not be using the BHT-7000 for more than one month: Remove the battery cartridge from the BHT-7000 and then store the BHT. To do so, be sure to follow the procedure given below. (1)
When removing the battery cartridge: Press the PW key for more than 3 seconds to power off the BHT-7000. The following message will appear on the LCD and the BHT will start backing up data. After completion of the backup operation so that the message disappears, remove the battery cartridge. (The backup operation may take several tens of seconds depending upon the volume of data to be backed up.)
Shows the current backup state in progress.
Now saving data. Do not remove batteries until saving process complete.
Shows the total volume of data to be backed up.
27
Page 44
(2)
When powering on the BHT after storage with no battery cartridge loaded: Even after removal of the battery cartridge, the calendar clock will work with the backup power source for a while. If the calendar clock backup has stopped, loading the battery cartridge and powering on the BHT will display the following message, prompting you to set the current date and time. Set the calendar clock according to the procedure given in Subsection 2.4.2. (The indication "00/01/01 00:00" will vary depending upon the calendar clock state.)
Set the current date and time. 00/01/01 00:00 _ /
/
:
28
Page 45
Chapter 2. Getting Started the BHT-7000 and System Mode
2.5 Initializing the BHT-7000 System Initializing the system will lose program files and data files stored in the user area and the system settings will revert to the factory defaults.
You may delete font files by selecting the whole user area to be initialized. You need to initialize the system when: (1)
you want to delete all of the program files and data files.
(2)
the following message appears. Contact your administrator. Note the error number. (2XXX)
On the following pages is an initialization procedure.
29
Page 46
(1)
Selecting the memory area to be initialized INITIALIZE SYSTEM 1:USER AREA EXCEPT FONTS
Press the PW key while holding down the SF , M1 and 0 keys together. The screen shown at left will appear. To initialize the user area except for the font file area, press the ENT key. The screen switches to the confirmation display given in step (3) below. To initialize the whole user area including the font file area, press the 2 key while holding down the SF key. The area selection screen will appear.
(Area selection screen)
INITIALIZE SYSTEM 1:USER AREA EXCEPT FONTS 2:WHOLE USER AREA
1 USER AREA EXCEPT FONTS: Initializes the user area except for the font file area. 2 WHOLE USER AREA: Initializes the whole user area including the font file area.
If the message "Contact your administrator. Note the error number. (2XXX)" appears on the LCD, you need to select "2: WHOLE USER AREA" to initialize the whole user area. Select an area to be initialized by using the numerical keys, then press the ENT key.
(2)
Selecting the English or Japanese message version
1:Japanese
Preceding the execution of initialization, the message version selection screen will appear as shown at left.
2:English
1 Japanese
: Switches the message version to Japanese.
2 English
: Switches the message version to English.
SELECT MESSAGE
Select a desired item by using the numerical keys, then press the ENT key.
30
Page 47
Chapter 2. Getting Started the BHT-7000 and System Mode
(3)
Confirming the memory area selected for initialization INITIALIZE SYSTEM OK? 1:Yes 2:No
Selecting the "USER AREA EXCEPT FONTS" in step (1) above will call up the confirmation screen shown at left. 1 Yes : Starts initialization. 2 No : Cancels initialization and turns the power off. Select a desired item by using the numerical keys, then press the ENT key. Pressing the C key will switch the screen back to the area selection screen.
INITIALIZE SYSTEM OK? 1:Yes 2:No Warning Initializing the whole user area will lose the font files.
Selecting the "WHOLE USER AREA" in step (1) above will call up the screen shown at left. 1 Yes:
Starts initialization.
2 No:
Cancels initialization and turns the power off.
Select a desired item by using the numerical keys, then press the ENT key. Pressing the C key will switch the screen back to the area selection screen.
(4)
During initialization INITIALIZE SYSTEM
During initialization, the screen shown at left is displayed.
** Initializing **
0
31
Page 48
(5)
Completion of initialization INITIALIZE SYSTEM ** Completed **
Upon completion of the initialization, the BHT-7000 displays the screen shown at left for a second and turns itself off automatically.
Do not power off the BHT-7000 until the above initialization completion screen appears. A too-early powering-off will interrupt initialization, requiring you to initialize the BHT-7000 again. If the message "Contact your administrator. Note the error number. (2XXX)" appears although the initialization has completed, initialize the BHT-7000 again. If you initialize the BHT-7000 after downloading user programs and data, all of those programs and data stored in the target memory area will be lost. Download them again if necessary. Initialization will restore the LCD contrast level (refer to Subsection 2.4.3), communications conditions and other settings to the default values, so modify them if necessary. After initialization, be sure to set the calendar clock (refer to Subsection 2.4.2).
32
Page 49
Chapter 2. Getting Started the BHT-7000 and System Mode
2.6 Operating in System Mode System Mode is an operating software exclusively designed for the effective use of the BHT-7000, which includes various functions as shown on the following pages.
2.6.1 Starting System Mode To start up System Mode, power on the BHT-7000 while holding down the SF and 1 keys. This operation calls up the SYSTEM MENU on the LCD as shown below. SYSTEM MENU 1:EXECUTE PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VERSION
The function selected is highlighted (white-on-black) with the cursor. To select a desired item in System Mode, press the corresponding numerical key and then press the ENT key. The keys below are so designed that the function of each key is consistent in every screen. Numerical keys
Pressing a numerical key corresponding with a desired menu number selects the desired item displayed on the screen.
ENT key
Pressing this key registers the selected item and executes the corresponding function.
and keys on the 32-key pad and keys ( F5 and F6 keys) moves Pressing the the cursor up and down, respectively, to select a desired item.
( F5 and F6 keys on the 26-key pad) and keys on the 32-key pad ( F7 and F8 keys on the 26-key pad)
Pressing the and keys ( F7 and F8 keys) moves the cursor to the left and right, respectively, to select a desired setting.
The C key is inoperative on the SYSTEM MENU. On other screens, pressing the C key returns to the immediately preceding screen. The power-on default is "EXECUTE PROGRAM" which is highlighted. Once any other item is selected, the selected item will become highlighted with the cursor when you turn back to the SYSTEM MENU.
33
Page 50
■ Structure of System Mode SYSTEM MENU 1:EXECUTE PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VERSION
SYSTEM MENU ⇐ Press the PW key while holding down the SF and 1 keys.
1 and ENT
EXECUTE PROGRAM
2 and ENT
DOWNLOAD
SAMPLE01.PD3 SAMPLE02.PD3 SAMPLE03.PD3 SAMPLE04.PD3 SAMPLE05.PD3
1:FILE 2:HT<-->HT COPY
3 and ENT
UPLOAD 1:ONE FILE 2:ALL FILES 3:HT<-->HT COPY
Program Execution Allows you to select a desired user program to be executed immediately. (Refer to Subsection 2.6.3, [ 1 ].)
Downloading Transfers user program files or data files from the host computer to the memory integrated in the BHT-7000. Downloading between the BHTs is also possible. (Refer to Subsection 2.6.3, [ 2 ].) Uploading Transfers user program files and data files stored in the memory of the BHT7000 to the host computer. (Refer to Subsection 2.6.3, [ 3 ].)
C 4 and ENT
SET SYSTEM 1:EXECUTE PROGRAM 2:DISPLAY 3:DATE/TIME 4:BARCODE 5:COMMUNICATION 6:KEY 7:RESUME
34
System Environment Setting Sets a variety of environmental conditions - an execution program, message version (English or Japanese), calendar clock, special bar-code scanning parameters, interface port, communications parameters, shift-key & magic key functions, and resume function (Refer to Subsection 2.6.3, [ 4 ].)
Page 51
Chapter 2. Getting Started the BHT-7000 and System Mode
5 and ENT
TEST 1:BARCODE 2:MEMORY 3:BEEPER 4:AGING 5:LCD 6:FILE 7:COMMUNICATION 8:KEY & VIBRATION
SYSTEM INFORMATION
6 and ENT
SYSTEM Ver. : X.XXX ROM SIZE : XXMB RAM SIZE : XXXKB SYSTEM MESSAGE: Japanese X.XX FONT ENT
35
Testing Used for the bar-code reading test, memory test, beeper test, aging test, LCD indication test, indicator LED test, communications test, key-entry test, vibrator test, and file test. (Refer to Subsection 2.6.3, [ 5 ].) System Information Shows the system program version, memory size, system message version, and font type and version (Refer to Subsection 2.6.3, [ 6 ].)
Page 52
In addition to the functions given on the previous page, System Mode has these four functions: Deleting files, Downloading/uploading the BHT system parameter file, Setting the remote wake-up parameters, and Downloading/uploading the system message file. To call up these functions, press the 0 , 3 , 4 or 6 key, respectively, while holding down the SF key when the SYSTEM MENU is displayed.
SYSTEM MENU 1:EXECUTE PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VERSION
SYSTEM MENU ⇐ Press the PW key while holding down the SF and 1 keys.
0 with SF held down
DELETE FILE
3 with SF held down
SYSTEM PARAMETER
4 with SF held down
SET REMOTE WAKEUP
6 with SF held down
SAMPLE01.PD3 SAMPLE02.PD3 SAMPLE03.PD3 SAMPLE04.PD3 SAMPLE05.PD3 SAMPLE06.PD3
1:DOWNLOAD 2:UPLOAD
1:REMOTE WAKEUP ON OFF 2:TRANSMIT SPEED 9600 19200 38400 57600 115200
SYSTEM MESSAGE 1:DOWNLOAD 2:UPLOAD
36
Deleting Files Deletes a program file or data file stored in the memory. (Refer to Subsection 2.6.3, [ 7 ].)
Downloading/uploading the BHT system parameter file Downloads or uploads the system parameter file. (Refer to Subsection 2.6.3, [ 8 ].)
Setting the remote wake-up parameters Sets the remote wake-up parameters. (Refer to Subsection 2.6.3, [ 9 ].)
Downloading/uploading the system message file Downloads or uploads the system message file. (Refer to Subsection 2.6.3, [ 10 ].)