The text of a manual · part 15 of 20
Bar Code Handy Terminal BHT-7000 User's Manual: Chapter 4 Error Messages
Pages 119 to 130 of 175, from Bar Code Handy Terminal BHT-7000 User's Manual
The original document is the PDF (934 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Denso BHT-7000
Page 119
Chapter 4. Error Messages
This chapter lists the error messages which will appear on the LCD if some error occurs in the BHT-7000.
4.1
System Errors ....................................................................................... 104
4.2
Errors in System Mode ........................................................................ 110
Chapter 4 Error Messages
103
Page 120
4.1 System Errors If some error occurs when the power is turned on or during program execution, one of the following error messages will appear on the LCD.
System Program error ■ Problem ****************** ** No System! ** ******************
A System Program error has occurred.
If this error occurs, the BHT-7000 beeps five times (for 0.1 second per beep) and then turns itself off. ■ Solution Contact your nearest dealer.
Low battery indication - Level 1 ■ Problem Battery voltage has lowered.
When the power is turned on or off or during execution of program (System Mode or application), the battery output level has dropped below a specified lower level limit.
If low battery is detected, the BHT-7000 displays this message for approx. 2 seconds and beeps three times (for 0.1 second per beep). After that, it will resume previous regular operation. ■ Solution The service life of the battery cartridge will expire soon, requiring replacement or recharge. If the BHT-7000 is loaded with the rechargeable battery cartridge, replace or charge it. (For the charging procedure, refer to Chapter 5, Section 5.5.) If the BHT-7000 is loaded with the dry battery cartridge, replace the dry cells.
104
Page 121
Chapter 4. Error Messages
Low battery indication - Level 2 (When the rechargeable battery cartridge is loaded)
Charge the battery!
(When the dry battery cartridge is loaded)
Replace the batteries!
■ Problem When the power is turned on or during execution of program (System Mode or application), the battery output level has lowered.
If lower battery is detected, the BHT-7000 beeps five times (for 0.1 second per beep) and then turns itself off. Depending upon the battery level, the beeper may not sound five times. ■ Solution If the BHT-7000 is loaded with the rechargeable battery cartridge, replace or charge it. (For the charging procedure, refer to Chapter 5, Section 5.5.) If the BHT-7000 is loaded with the dry battery cartridge, replace the dry cells.
105
Page 122
Calendar clock stopped ■ Problem
Set the current date and time.
The calendar clock integrated in the BHT-7000 has stopped because:
00/01/01 00:00 _ /
/
- The battery cartridge had been removed for a long time,
:
- The rechargeable battery cartridge had not been recharged for a long time, or - The dry batteries in the dry battery cartridge had not been replaced.
The indication of 00/01/01 00:00 will change depending upon the calendar clock state. ■ Solution Set the calender clock (refer to Chapter 2, Subsection 2.4.2).
System Program malfunction ■ Problem Reload the battery to restart!
XXXXXXXX
During execution of System Program, the System Program has attempted to write onto the write-protected area of the memory. 01
(xxxxxxxx: Error address)
If this error occurs, the BHT-7000 beeps five times (for 0.1 second per beep). ■ Solution Unload and reload the battery cartridge, then turn on the power.
■ Problem Reload the battery to restart!
During execution of System Program, the System Program has received an invalid command code.
tskid:XXXXXXXX ercd :XXXXXXXX addr :XXXXXXXX
(xxxxxxxx: Error address) 02
If this error occurs, the BHT-7000 beeps five times (for 0.1 second per beep). ■ Solution Unload and reload the battery cartridge, then turn on the power.
106
Page 123
Chapter 4. Error Messages
Execution program not selected ■ Problem No execution program selected. Contact your administrator.
No user program has been selected as an execution program to be run when the power is turned on.
If this error occurs, the BHT-7000 beeps five times (for 0.1 second per beep) and then turns itself off. ■ Solution Run System Mode and select an execution program in the SET SYSTEM menu. (For the selecting procedure, refer to Chapter 2, Subsection 2.6.3, [4.1].)
Resume data saving error ■ Problem Resume failure! Program restarts automatically.
When the power was turned off, the system failed to save resume data although the resume function had been set to ON.
The BHT-7000 displays this error message for three seconds and automatically runs the execution program from the point of start-up.
107
Page 124
Error in System Mode settings Your settings in System Mode have been lost. Will reset to defaults.
■ Problem Your settings made in System Mode contain an error.
If this error occurs, the System Mode settings revert to the factory defaults. The BHT-7000 displays this error for three seconds and then displays the "No execution program selected…" message. ■ Solution Make your settings in System Mode again.
System down error ■ Problem Reload the battery to restart! E:xxxxxxxx-F:xxxxxxxx 1:xxxxxxxx-2:xxxxxxxx P:xxxxxxxx-R:xxxxxxxx
An error has occurred during execution of System Program.
If this error occurs, the BHT-7000 beeps five times (for 0.1 second per beep). ■ Solution Unload and reload the battery cartridge, then turn on the power. If this error occurs frequently, make a note of the message and codes on the LCD and contact your nearest dealer.
108
Page 125
Chapter 4. Error Messages
System administrator to be called Contact your administrator. Note the error number. (XXXX)
■ Problem Any of the following errors has occurred: (1) Hardware error or calendar clock error: (1010) Flash memory error: (1020) (2) Memory storage error
(20XX)
(3) Execution program error (XXXX: Error code)
(3010)
If any of the above errors occurs, the BHT7000 beeps five times (for 0.1 second per beep) and then turns itself off. ■ Solution Turn on the power again. If error (1) above occurs frequently, contact your nearest dealer. If error (2) occurs frequently, initialize the BHT7000 System (the whole user area including the font file area). If error (3) occurs frequently, delete the execution program file that causes this error or download the original execution program file to overwrite the current one.
109
Page 126
4.2 Errors in System Mode If some error occurs during operation in System Mode, one of the following error messages will appear on the LCD.
When selecting a program file or data file EXECUTE PROGRAM ****************** * NO FILE EXISTS * ******************
■ Problem You attempted to execute a user program in the EXECUTE PROGRAM menu, even though no user program files had been stored in the memories.
■ Solution Press the C key to return to the SYSTEM MENU screen, then download user programs. (Refer to Chapter 2, Subsection 2.6.3, [ 2 ].)
SET EXECUTE PROGRAM
■ Problem
****************** * NO FILE EXISTS * ******************
In the SET SYSTEM menu, you attempted to select a user program file as an execution program to be run when the power is applied, even though no user program files had been stored in the memories.
■ Solution Press the C key to return to the SYSTEM MENU screen, then download user programs. (Refer to Chapter 2, Subsection 2.6.3, [ 2 ].)
UPLOAD FILE ****************** * NO FILE EXISTS * ******************
■ Problem You attempted to select "ONE FILE" or "ALL FILES" for uploading in the UPLOAD menu, even though no data files had been stored in the memory.
■ Solution Press the C key to return to the SYSTEM MENU screen.
110
Page 127
Chapter 4. Error Messages
DELETE FILE ****************** * NO FILE EXISTS * ******************
■ Problem You have deleted all of the files stored in the memory in the DELETE FILE menu.
■ Solution Press the C key to return to the SYSTEM MENU screen.
During downloading of a program file, data file, BHT-7000 system parameter file, or system message file DOWNLOAD FILE
■ Problem
XXXXXXXX.XXX Out of memory!!
The memory is insufficient for storing files to be downloaded.
Retry? 1:Yes 2:No
■ Solution Press the 2 key to return to the SYSTEM MENU, then delete unnecessary files in the memory or decrease the size of the file to be downloaded. (Refer to Chapter 2, Subsection 2.6.3, [ 7 ], [ 2 ], [ 8 ], and [ 10 ].)
DOWNLOAD File mismatch!! Retry? 1:Yes 2:No
■ Problem In the SYSTEM PARAMETER transfer menu, you attempted to download a file other than the BHT7000 system parameter file. Or in the SYSTEM MESSAGE transfer menu, you attempted to download a file other than the system message file.
■ Solution Check the file you attempted to download and then download the file in the appropriate menu (DOWNLOAD menu, SYSTEM PARAMETER transfer menu, or SYSTEM MESSAGE transfer menu).
111
Page 128
DOWNLOAD FILE
■ Problem
XXXXXXXX.XXX Too many files!!
The current download will exceed the maximum of 80 files in the memory.
Retry? 1:Yes 2:No
■ Solution Press the 2 key to return to the SYSTEM MENU, then delete unnecessary files in the memory (or decrease the number of files to be downloaded if you attempted to download more than one file in the DOWNLOAD menu.) (Refer to Chapter 2, Subsection 2.6.3, [ 7 ], [ 2 ], [ 8 ], and [ 10 ].)
DOWNLOAD FILE XXXXXXXX.XXX Communication error!! Retry? 1:Yes 2:No
■ Problem Downloading has failed.
■ Solution To retry downloading, press the 1 key. To return to the SYSTEM MENU, press the 2 key. Check the interface port and communications parameters in the SET SYSTEM menu or perform the communications test in the TEST menu. (Refer to Chapter 2, Subsection 2.6.3, [4.5] and [5.7].) It is also necessary to check the communications parameters setup of the host computer.
DOWNLOAD FILE XXXXXXXX.XXX Program file error!! Retry? 1:Yes 2:No
■ Problem You attempted to download an invalid program file.
■ Solution Check whether the program file you attempted to download is available to your BHT model. If it is not available, download the appropriate program.
112
Page 129
Chapter 4. Error Messages
During uploading of a program file, data file, BHT system parameter file, or system message file UPLOAD FILE File error!!
■ Problem The file you attempted to upload is damaged.
Upload? 1:Yes 2:No
■ Solution
UPLOAD
■ Problem
Out of memory!!
To upload the damaged file as is, press the 1 key.
The memory is insufficient for setting up the BHT system parameter file or system message file to be uploaded.
■ Solution Press the C key to return to the SYSTEM MENU and delete unnecessary files. (Refer to Chapter 2, Subsection 2.6.3, [ 7 ].)
UPLOAD Too many files!!
■ Problem The memory has already contained 80 files, so the BHT system parameter file or system message file cannot be set up.
■ Solution Press the C key to return to the SYSTEM MENU and delete unnecessary files. (Refer to Chapter 2, Subsection 2.6.3, [ 7 ].)
UPLOAD FILE XXXXXXXX.XXX Communication error!! Retry? 1:Yes 2:No
■ Problem Uploading has failed.
■ Solution To retry uploading, press the 1 key. To return to the SYSTEM MENU, press the 2 key. Check the interface port and communications parameters in the SET SYSTEM menu or perform the communications test in the TEST menu. (Refer to Chapter 2, Subsection 2.6.3, [4.5] and [5.7].) It is also necessary to check the communications parameters setup of the host computer.
113
Page 130
114