Page 58
Chapter 2. Getting Started the BHT-5000 and System Mode
[4.5]
Setting the communications parameters and interface port
After the BHT-5000 is initialized, the communications parameters and the interface port to be used are set as listed in the default table below. Do not access them unless necessary. Communications parameters
Defaults
Transmission speed
19,200 bps
Character length
8 bits
Parity
None
Stop bits
1 bit
Protocol
Serial number ON:
Adds serial numbers to data blocks.
Horizontal parity ON:
Adds a horizontal parity.
RS/CS control OFF:
Disables the RS/CS control.
Timeout:
30 seconds
Last space:
Ignore
Interface port
SET COMMUNICATION 1:Optical 2:Connector 3:Default
Optical interface port
Selecting "5: Communication" on the SET SYSTEM menu calls up the screen shown at left. 1 Optical
: Shifts to the parameter/protocol selection screen for the optical interface. (The CU-5000 is required.)
2 Connector : Shifts to the parameter/protocol selection screen for the direct-connect interface. 3 Default
: Shifts to the interface port setting screen.
Select a desired screen by using the numerical keys or * and * keys, and then press ENT key. To return to the SET SYSTEM menu, press C key.
* For BHT-5000s having a 26-key pad, use F5 and F6 keys instead of respectively
43 and keys,
Page 59
Setting the parameters and protocol SET COM OPTICAL 1:Parameter 2:Protocol
Selecting "1: Optical" or "2: Connector" on the SET COMMUNICATION menu calls up each of the screens as shown at left. The selected interface port (OPTICAL or CONNECTOR) is shown on the 1st line of the LCD. 1 Parameter : Shifts to the parameter setting screen (for selecting the transmission speed, character length, parity, and stop bits).
SET COM CONNECTOR 2 Protocol
1:Parameter 2:Protocol
: Shifts to the protocol setting screen (for selecting the serial number, horizontal parity, RS/CS control, timeout, and last space).
Reversed is the current setting. Select a desired screen by using the numerical keys or * and * keys, and then press ENT key. To return to the SET COMMUNICATION menu, press C key.
On the parameter setting screen ("1: Parameter" has been selected) SET COM PARAMETER 1:Speed: 1200 2400 4800 9600 19200 38400 2:Data:7bits 8bits 3:Parity: None Odd Even 4:Stop:1bit 2bits
Selecting "1: Parameter" on either of the above screens (SET COM OPTICAL and SET COM CONNECTOR menus) calls up the screen as shown at left. Reversed is the current setting. 1 Speed : Selects the transmission speed: 1200, 2400, 4800, 9600, 19200, or 38400 bps. 2 Data
: Selects the character length: 7 bits or 8 bits.
3 Parity : Selects the parity: none, odd, or even. 4 Stop
: Selects the stop bit length: 1 bit or 2 bits.
Select a desired item by using the numerical keys or * and * keys, and then select a desired setting by using * and * keys. To return to the SET COM OPTICAL or SET COM CONNECTOR menu, press C key. * For BHT-5000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
44
,
,
Page 60
Chapter 2. Getting Started the BHT-5000 and System Mode
On the protocol setting screen ("2: Protocol" has been selected) SET COM PROTOCOL 1:Serial No: ON OFF 2:H.Parity : ON OFF 3:RS/CS : ON OFF 4:Timeout : 30 60 90 120 NONE 5:Last Space: Ignore Data
Selecting "2: Protocol" on either of the SET COM OPTICAL and SET COM CONNECTOR menus calls up the screen as shown at left. Reversed is the current setting. 1 Serial No. : Selects whether or not the system should add serial numbers to data blocks. 2 H. Parity
: Selects whether or not the system should add a horizontal parity.
3 RS/CS
: Selects whether or not the system should control the RS/CS signal.
4 Timeout
: Selects the timeout length (in seconds) to be applied when a link will be established.
5 Last Space : Selects whether space codes in the tail of a data field should be ignored or handled as data. Select a desired item by using the numerical keys or * and * keys, and then select a desired setting by using * and * keys. To return to the SET COM OPTICAL or SET COM CONNECTOR menu, press C key.
REFERENCE
"5: Last Space" allows you to determine how to handle space codes placed in the tail of a data field when downloading data files. If you select "Ignore," those space codes will be eliminated; if you select "Data," those will be handled as data. For details, refer to the "BHTBASIC 3.0 Programmer's Manual," Appendix G.
* For BHT-5000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
45
,
,
Page 61
Setting the interface port SET COM DEFAULT 1:BASIC Optical Connector 2:SYSTEM MODE Optical Connector
Selecting "3: Default" on the SET COMMUNICATION menu calls up the screen shown at left. Reversed is the current setting. 1 BASIC
: Selects the optical or directconnect interface port to be used for user programs written in BHT-BASIC 3.0 ("COM:" or XFILE statement).
2 SYSTEM MODE : Selects the optical or directconnect interface port to be used for downloading or uploading files in System Mode. Select a desired item by using the numerical keys or * and * keys, and then select a desired setting by using * and * keys. To return to the SET COMMUNICATION menu, press C key.
* For BHT-5000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
46
,
,
Page 62
Chapter 2. Getting Started the BHT-5000 and System Mode
[4.6]
Defining the functions of the shift key and magic keys
SET KEY 1:Shift lock Nonlock Onetime 2:M1 No ENT Trig. SFT BL 3:M2 No ENT Trig. SFT BL
Selecting "6: Key" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 Shift lock : Switches the function of SF key. Nonlock: The keypad will be shifted only when SF key is held down. Onetime: Once SF key is pressed, the next one key pressed will be shifted and the following keys will not be shifted. 2 M1
: Defines magic key M1 as listed below.
3 M2
: Defines magic key M2 as listed below. No
The key entry will be ignored.
ENT
Acts as ENT key.
Trig.
Acts as the trigger switch.
SFT
Acts as SF key.
BL
Acts as the backlight function on/off key.
Select a desired item by using the numerical keys or * and * keys, and then select a desired setting by using * and * keys. To return to the SET SYSTEM menu, press C key.
Magic keys M1 and M2 You can make M1 and M2 keys act as ENT key, trigger switch, SF key, or backlight function on/off key. If you define M1 key as the backlight function on/off key, pressing M1 key activates or deactivates the backlight function. In user programs, a string data also can be assigned to these magic keys.
NOTE
If both M1 and M2 keys are defined as the backlight function on/off key, M2 key will act as the backlight function on/off key; M1 key will be ignored.
* For BHT-5000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
47
,
,
Page 63
[4.7]
Setting others (resume function and BHT-2000 compatible mode)
OTHERS 1:RESUME: ON OFF 2:BHT-2000: ON OFF
Selecting "7: Others" on the SET SYSTEM menu calls up the screen shown at left. Reversed is the current setting. 1 Resume : Activates or deactivates the resume function which resumes whatever display was shown before the power was turned off, when the BHT-5000 is powered up. 2 BHT-2000 : Turns the BHT-2000 compatible mode on or off. Select a desired item by using the numerical keys or
* and
* keys, and then select a desired setting by using
* and
* keys.
To return to the SET SYSTEM menu, press C key.
BHT-2000 compatible mode This compatible mode allows user programs written for the BHT-2000 to run on the BHT-5000. When those user programs are running, they use only the middle section of the LCD for displaying. (The BHT-5000 is larger than the BHT-2000 in the numbers of columns and lines.)
NOTE
When the BHT-5000 is placed in the BHT-2000 compatible mode, it cannot run user programs written for the BHT-5000. Even in this mode, some functions such as the frequencies of the beeper are not compatible. For details, refer to the "BHT-BASIC 3.0 Programmer's Manual." Some user programs written for the BHT-2000 may not work correctly in this mode.
* For BHT-5000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
48
,
,
Page 64
Chapter 2. Getting Started the BHT-5000 and System Mode
[ 5 ] Testing TEST 1:BARCODE 2:MEMORY 3:KEY 4:LCD 5:AGING 6:COM 7:BEEPER 8:FILE
Selecting "5: Test" on the SYSTEM MENU calls up the screen shown at left. 1 BARCODE : Selects the bar-code reading test. 2 MEMORY : Selects the RAM test. 3 KEY
: Selects the key entry & beeper test.
4 LCD
: Selects the LCD and reading confirmation LED tests.
5 AGING
: Selects the aging test.
6 COM
: Selects the communications test.
7 BEEPER
: Selects the beeper test.
8 FILE
: Selects the file test.
Select a desired item by using the numerical keys, then press ENT key. Reversed is the current setting. To return to the SYSTEM MENU, press C key.
NOTE
If an error occurs in any of the above tests, contact your nearest dealer.
49
Page 65
[5.1]
Bar-code reading test TEST BARCODE
Selecting "1: BARCODE" on the TEST menu calls up the screen shown at left. Actually read bar codes with the BHT-5000 and check the read data displayed on the LCD.
⇓ Bar-code type Number of digits of the bar code
TEST BARCODE
Upon completion of bar-code reading, the BHT5000 beeps, turns on the reading confirmation LED in green, and displays the read data together with the bar-code type and the number of data digits.
B 08 49400403
Data
Listed below is a table showing the relationship between the bar-code types and the identifier letters to be displayed on the LCD. (CODE39 sample)
TEST BARCODE
M 15 123456789012345
Bar-code Type
ID Letters
EAN-13, UPC-A
A
EAN-8
B
UPC-E
C
Standard 2 of 5 (STF)
H
Interleaved 2 of 5 (ITF)*
I
CODABAR (NW7)
N
CODE39
M
CODE93
L
CODE128
K
* The BHT-5000 can read only those ITF bar codes having 4 digits or more in length.
To return to the TEST menu, press C key.
50
Page 66
Chapter 2. Getting Started the BHT-5000 and System Mode
[5.2]
Memory test TEST MEMORY Testing XXXXX/YYYYY
TEST MEMORY Test NG XXXXX/YYYYY Address:hhmmll Write :AA Read :BB
Selecting "2: MEMORY" on the TEST menu calls up the screen shown at left and starts writing and reading onto/from all areas of the RAM. xxxxx:
Tested RAM capacity (unit: kilobytes)
yyyyy:
Total RAM capacity (unit: kilobytes)
If any error is detected, the BHT-5000 beeps, shows the message as shown at left, and terminates the test. Where, hhmmll: Address where an error has occurred. AA:
Data to write.
BB:
Data read out from the RAM.
To return to the TEST menu, press C key.
TEST MEMORY Test OK YYYYY/YYYYY
Upon normal completion of the RAM test, the BHT5000 beeps, shows the message as shown at left, and returns to the TEST menu.