Page 132
Appendices
Appendix A. Specifications ..................................................................................................... 118 A.1 BHT-5000 ......................................................................................................................... 118 [ 1 ] Product Specifications ........................................................................................... 118 [ 2 ] Bar Code Specifications ......................................................................................... 119 [ 3 ] Interface Specifications .......................................................................................... 121 A.2 CU-5000 ........................................................................................................................... 122 [ 1 ] Product Specifications ........................................................................................... 122 [ 2 ] Charging/Discharging Requirements (CU-5001) .................................................. 122 [ 3 ] Interface Specifications .......................................................................................... 123 Appendix B. A Typical Basic Operation ................................................................................. 124
Appendices
117
Page 133
Appendix A. Specifications A.1 BHT-5000 [ 1 ] Product Specifications Power Source
Main power
Backup power
Battery cartridge - Rechargeable Ni-MH battery cartridge (2.4 VDC) or - Dry battery cartridge containing two LR6s (1.5 VDC x 2) Integrated lithium battery, 3.0 VDC
Dimensions (W) x (L) x (H)
77 x 197 x 50 mm (3.03 x 7.76 x 1.97 inches)
Weight
Approx. 280 g (Approx. 9.9 oz.) including the battery cartridge
Operating Ambient Temperature
0˚C to 40˚C (32˚F to 104˚F)
Operating Humidity
20% to 80% (with no dew condensation)
Ambient Illuminance
• 3,000 lux. max. (Depth of field : 0 mm, PCS value: 0.75 min., Minimum narrow bar width: 0.125 mm min., CODE39, ITF, NW7) • 20 to 10,000 lux. (Depth of field: 100 mm, ITF: 1.0 magnification, PCS value: 0.9 min., Reflection intensity: 85% min. for white and 5% max. for black)
Controller
Keypad
CPU: 16-bit CMOS RAM: 128KB/512KB/1MB/2MB Flash ROM: 512KB 32-key pad
Function keys: 10 Magic keys: 2 Numerical keys and others: 20
26-key pad
Function keys: 8 Magic keys: 2 Numerical keys and others: 16
Display
Type:
Dot-matrix, FSTN liquid crystal display (LCD) with backlight
Formation:
128 dots wide by 64 dots high Chars x Lines
Dots (W x H)
Alphanumerics
21 x 8
5x7
Full-width (16 dots)
8x4
16 x 16
Full-width (12 dots)
10 x 4
12 x 16
Calendar Clock
Year, month, day, hour, minute, and second with compensation for leap years
Reading Confirmation LED
Colors: Red and green 118
Page 134
Appendices
[ 2 ] Bar Code Specifications (1) Available Bar Code Types Bar code type
Readable range
Bar dimensions
0.8 to 2.0 magnifications
0.26 to 0.66 mm (10.24 to 25.98 mils)
2-digit add-on
0.8 to 1.4 magnifications
0.26 to 0.46 mm (10.24 to 18.11 mils)
5-digit add-on
0.8 to 1.1 magnifications
0.26 to 0.39 mm (10.24 to 15.35 mils)
2-digit add-on
0.8 to 2.0 magnifications
0.26 to 0.66 mm (10.24 to 25.98 mils)
5-digit add-on
0.8 to 1.6 magnifications
0.26 to 0.55 mm (10.24 to 21.65 mils)
2-digit add-on
0.8 to 1.4 magnifications
0.26 to 0.46 mm (10.24 to 18.11 mils)
5-digit add-on
0.8 to 1.1 magnifications
0.26 to 0.39 mm (10.24 to 15.35 mils)
2-digit add-on
0.8 to 2.0 magnifications
0.26 to 0.66 mm (10.24 to 25.98 mils)
5-digit add-on
0.8 to 1.6 magnifications
0.26 to 0.55 mm (10.24 to 21.65 mils)
Universal product codes EAN-13 EAN-8 UPC-A UPC-E EAN-13 with supplemental codes
EAN-8 with supplemental codes
UPC-A with supplemental codes
UPC-E with supplemental codes
Interleaved 2 of 5 (ITF)
2 to 58 digits*
Standard 2 of 5 (STF)
1 to 34 digits
CODABAR (NW7)
3 to 37 digits
CODE39
1 to 30 digits
CODE93
1 to 36 digits
CODE128
1 to 30 digits
0.125 mm min. ** (4.92 mils min.)
0.15 mm min. (5.91 mils min.) * Only even-numbered digits ** PCS value: 0.75 min.
(2) Optical Properties Required for Bar Code Labels White bars: Reflection intensity
45% min.
Black bars:
25% max. 0.45 min.
Reflection intensity PCS value
119
Page 135
(3) Bar Code Label Size Recommended width: 10 mm min. (0.39 inch min.) Length:
Depth of field (Distance from bar codes to the bar-code reading window)
Length of labels (including margins)
0 mm
60 mm max. (2.36 inches max.) (Minimum narrow bar width: 0.125 mm min.)*
200 mm (7.87 inches)
280 mm max. (11.02 inches max.) (Minimum narrow bar width: 1.2 mm min.)***
Length
Width
123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890
(4) Thickness of Bars and Depth of Field Minimum narrow bar width
Depth of field
0.15 mm (5.91 mils) 0.33 mm (12.99 mils) 0.6 mm (23.62 mils) 1.0 mm (39.37 mils) 1.2 mm (47.24 mils)
5 mm (0.19 inch) ** 40 mm (1.57 inches) ** 80 mm (3.15 inches) *** 160 mm (6.30 inches) *** 200 mm (7.87 inches) *** *Under the following conditions: • Ambient illuminance: 3,000 lux. max. • CODE39, ITF, NW7 • PCS value: 0.75 min. **Under the following conditions: • Ambient illuminance: 500 lux. (fluorescent lamp) • ITF 20 digits • PCS value: 0.9 min. ***Under the following conditions: • Ambient illuminance: 500 lux. (fluorescent lamp) • ITF conforming to the UPC Shipping Container Code • PCS value: 0.9 min.
120
Page 136
Appendices
[ 3 ] Interface Specifications Optical Interface Synchronization:
Start-stop
Input signals:
RD and CS
Output signals:
SD and RS
Transmission speed:
38400 bps max.
Direct-connect Interface Synchronization:
Start-stop
Transmission speed:
38400 bps max.
Signal level:
Conforms to the RS-232C interface
Pin assignment:
As shown below.
SD
Pin No.
Signal
1
SG (GND)
2 3
RD
GND
Signal Input/Output External BHT-5000 device
Functions
Ground for signals and charging pins, SD
Send data
→
RD
Receive data
←
121
Page 137
A.2 CU-5000 [ 1 ] Product Specifications Power Source
CU-5001: 12 VDC (via the AC adapter)
Power Consumption
CU-5002: 2W
Dimensions (W) x (L) x (H)
90 x 215 x 45 mm (3.54 x 8.46 x 1.77 inches)
Weight
CU-5001: Approx. 240 g (Approx. 8.47 oz.) CU-5002: Approx. 180 g (Approx. 6.35 oz.)
Operating Ambient Temperature
0˚C to 40˚C (32˚F to 104˚F)
Operating Humidity
20% to 80% (with no dew condensation)
[ 2 ] Charging/Discharging Requirements (CU-5001) For charging a Ni-MH battery cartridge loaded in the BHT-5000 Charge current: Charge time:
110 mA Approx. 10 hours
For charging a Ni-MH battery cartridge all by itself Charge current: Charge time: Discharge current: Discharge time:
110 mA Approx. 10 hours 310 mA Approx. 25 minutes (for battery cartridges that the BHT-5000 detects as a "low" battery)
122
Page 138
Appendices
[ 3 ] Interface Specifications 13
1
25
14
RS-232C Interface Port (Dsub-25S) on the CU-5000
Pin No.
Signal
Functions
Signal Input/Output External BHT-5000 device
2
SD
Send data
→
3
RD
Receive data
←
4
RS
Request to send
→
5
CS
Ready to send
←
7
SG
Signal ground, 20
ER
Data terminal equipment ready
→
Pins 1 (FG), 6 (DR), and 8 (CD) are not connected.
123
Page 139
Appendix B. A Typical Basic Operation What follows is a typical basic operation which helps you instruct the hands-on user in practical bar-code reading operation. Application type: Inventory Operation:
Power ON → Read the bar code on stock (A). → Key in the quantity. Read the bar code on stock (B). → Key in the quantity.
. ..
Repeat the above operation.
.. .
6. Ready for data entry Record 00100 scrolls up so that record 00101 becomes ready for next data entry. File1 A:
96/02/20
MULTI K 00101
4. Display of read data A:0031323120786 B: MULTI K 00100
3. Bar code entry Bring the bar-code reading window to the bar code to be scanned and press the trigger switch.
2. Ready for data entry File1 A:
96/02/20
MULTI K 00100
5. Quantity entry Enter the quantity by pressing the numerical keys, then press ENT key. A:0031323120786 B:20
1. Power ON Press PW key to turn on the power.
MULTI K 00100
124