Page 93

3.2.2 Communications Parameters In System Mode and user programs written in BHT-BASIC 3.0, you may set the communications parameters listed below. Communications Port

Optical interface or direct-connect interface

Transmission Speed

300*, 600*, 1200, 2400, 4800, 9600, 19200, or 38400 bps

Character Length

7 or 8 bits

Vertical Parity

Odd, even, or none

Stop Bits

1 or 2 bits

RS/CS Control

Enabled or disabled * The 300 bps and 600 bps are not available in System Mode.

In System Mode Refer to Chapter 2, Subsection 2.4.3, "Detailed Description of the Functions in System Mode," [ 4.5 ] Setting the communications parameters and interface port.

In BHT-BASIC 3.0 To set the transmission speed, character length, and the number of stop bits, use the OPEN "COM:" statement in BHT-BASIC 3.0.

OPEN "COM: ... "

Opens the interface port selected in System Mode.

OPEN "COM1: ... "

Opens the optical interface port for data transmission routing through the CU-5000, irrespective of the setting in System Mode.

OPEN "COM2: ... "

Opens the direct-connect interface port for direct data transmission, irrespective of the setting in System Mode.

Note that it is impossible to open both the optical interface port and the direct-connect interface port concurrently. Through the interface port opened by the OPEN "COM:" statement, the XFILE statement transmits a designated file.

78

Page 94

Chapter 3. Communications Operations of BHT-5000

3.3 BHT-Protocol 3.3.1 Overview The BHT-protocol is the communications procedure used to transmit files between the BHT-5000 and a host (or between the BHT-5000s). It adopts the response method using ACK/NAK codes. The BHT-protocol is composed of a defined set of the control character sequences including the following three phases:

Phase 1:

Establishment of data link The sending station confirms that the receiving station is ready to receive data.

Phase 2:

Data transmission The sending station transmits data to the target receiving station.

Phase 3:

Release of data link The sending station confirms whether or not all of the transmitted data has been correctly received by the receiving station. If yes, the sending station terminates the data transmission and releases the data link.

79

Page 95

3.3.2 Control Characters The control characters are classified into two groups: transmission control characters and text control characters.

(1)

Transmission control characters

The transmission control characters listed below are used to compose transmission control sequences in phases 1 through 3. Symbol

Value

Meaning

Function

EOT

04h

End Of Transmission

Releases a data link (Phase 3). Requests abort of transmission (Phase 2).

ENQ

05h

Enquiry

Requests establishment of a data link (Phase 1). Prompts the receiver to respond to the sent text (Phase 2).

ACK

06h

Acknowledge

Acknowledgment response to ENQ (Phase 1). Acknowledgment response to text (Phase 2). Acknowledgment response to EOT (Phase 3).

NAK

15h

Negative Acknowledge

Negative acknowledgment response to ENQ (Phase 1). Negative acknowledgment response to text (Phase 2).

■ Transparency The BHT-5000 uses the non-transparent mode which handles the control characters and codes (e.g., STX, ETX, and SOH) as starting or ending markers and does not allow them to be transmitted as normal data in the transmission texts.

80

Page 96

Chapter 3. Communications Operations of BHT-5000

(2)

Text control characters

The text control characters are used to format transmission texts. In the BHT-protocol, they include the following headers and a terminator. Symbol

Value

Meaning

Function

SOH

01h

Start Of Heading

Indicates the start of heading text (Phase 2).

STX

02h

Start Of Text

Indicates the start of data text (Phase 2).

ETX

03h

End Of Text

Indicates the end of data text (Phase 2).

You may designate headers and a terminator by the protocol functions in BHT-BASIC 3.0. If you designate none of them in a user program, the BHT-5000 may apply those as listed above. Refer to the "BHT-BASIC 3.0 Programmer's Manual."

81

Page 97

3.3.3 Basic Format of Transmission Messages Basically, the BHT-5000 transmits data as a unit of a file. First, it transmits a heading text which includes the attribute information of a file (e.g., file name and the number of data texts) to be transmitted. Following the heading text, it transmits the data text in the file. A heading text and data text comprise a text. In actual text transmission, the text is divided into several blocks, and a header and terminator are added to each block. If the serial number management or error checking by BCC (Block Check Character) is required, the serial number or BCC is also added to each block, respectively. This procedure forms a transmission block. A set of transmission blocks makes up one transmission message. Shown below is an example of a transmission message formed with the BHT-protocol.

Text

Heading text

S O H

Transmission Message

Data text 1

Data text 2

Heading text

Data text n

E T X

B C C

Transmission block

S T X

Serial number

Data text 1

E T X

B C C

Transmission block

S T X

Serial number

Data text n

E T X

B C C

Transmission block

In the above figure, SOH, STX, and ETX are text control characters as described in Subsection 3.3.2. The serial number is added to every data text in order to identify those texts. For BCC, refer to Subsection 3.3.6.

82

Page 98

Chapter 3. Communications Operations of BHT-5000

3.3.4 Transmission Control Sequences Shown below is a typical message transmission sequence supported by the BHTprotocol. This sequence example does not include transmission errors or negative responses. Sending Station

Establishment of Data Link (Phase 1)

Receiving Station

ENQ ACK

S O H

Heading text

E B T C X C ACK

S T Serial number X

Data text 1

E B T C X C ACK

Data Transmission (Phase 2)

S T Serial number X

Data text n-1

E B T C X C ACK

S T Serial number X

Data text n

E B T C X C ACK

Release of Data Link (Phase 3)

EOT ACK

83

Page 99

Data transmission may accidentally involve various types of errors. The BHT-protocol is designed to recover from those errors as frequently as possible. What follows is the BHT-protocol for phases 1 through 3.

Phase 1: Establishment of Data Link ■ Normal phase 1 The sending station transmits an ENQ to the receiving station. Upon receipt of an ACK from the receiving station, the sending station shifts to phase 2.

ENQ

Sending station

Receiving station

ACK

To phase 2.

■ Phase 1 with no response or invalid response If the sending station receives no response or any invalid response from the receiving station in response to an ENQ sent, it iterates sending of an ENQ at threesecond intervals up to 10 times. If the sending station receives an ACK before sending an ENQ ten times, it shifts to phase 2. Sending station 3 seconds

ENQ ENQ

3 seconds

ENQ

ACK

To phase 2.

84

Receiving station

Page 100

Chapter 3. Communications Operations of BHT-5000

■ Abnormal termination of phase 1 (Abort of phase 1) If the sending station receives no ACK from the receiving station after sending an ENQ 10 times in succession, it sends an EOT to the receiving station after three seconds from the 10th ENQ to terminate the message transmission abnormally.

Sending station

Receiving station

ENQ(1) 3 seconds

ENQ(2) 3 seconds

ENQ(3)

ENQ(10) 3 seconds

EOT Abnormal termination

85

Page 101

Phase 2: Data Transmission ■ Normal phase 2 The sending station first sends a transmission block containing the heading text. Each time the sending station receives an ACK from the receiving station, it sends a transmission block containing the data texts as shown below. Upon receipt of an ACK in response to the last transmission block (data text n), the sending station shifts to phase 3. If a transmission message contains no data text, the sending station transmits the heading text only.

Sending station

Receiving station Heading text

ACK

Data text 1

ACK

Data text n-1

ACK

Data text n

ACK

To phase 3.

86