Page 155

Appendices

Appendices Appendix A. Specifications ...................................................................................................... 146 A.1 BHT-4000 ......................................................................................................................... 146 [ 1 ] Product Specifications ........................................................................................... 146 [ 2 ] Bar Code Specifications ......................................................................................... 147 [ 3 ] Interface Specifications .......................................................................................... 149 A.2 CU-4000 ........................................................................................................................... 150 [ 1 ] Product Specifications ........................................................................................... 150 [ 2 ] Charging/Discharging Requirements .................................................................... 150 [ 3 ] Interface Specifications .......................................................................................... 151 Appendix B. A Typical Basic Operation .................................................................................. 152

145

Page 156

Appendix A. Specifications A.1

BHT-4000

[ 1 ] Product Specifications Power Source

Main power

Rechargeable Ni-Cd battery, 4.8 VDC

Backup power

Integrated lithium battery, 3 VDC

Dimensions (W) x (L) x (H)

93 x 235 x 67 mm (3.66 x 9.25 x 2.64 inches)

Weight

Approx. 380 g (Approx. 13.4 oz.) including the battery cartridge

Operating Ambient Temperature

0˚C to 40˚C (32˚F to 104˚F)

Operating Humidity

10% to 90% (with no dew condensation)

Ambient Illuminance

• 3000 lux max. (Depth of field: 0 mm, PCS value: 0.45 max., Minimum narrow bar width: 0.17 mm min.) • 200 to 20,000 lux. (Depth of field: 100 mm, ITF: 1.0 magnification, PCS value: 0.9 min., Reflection intensity: 0.85 min. for white and 0.05 min. for black)

Controller

Keypad

CPU:

16-bit CMOS

RAM:

256KB/768KB/2MB

ROM:

16KB for system use

Function keys:

8

Numerical keys and others: 16 Display

Type: Dot-matrix, FSTN liquid crystal display (LCD) with backlight Formation: 160 dots wide by 80 dots high Characters: Chars x lines

Dots (W x H)

Alphanumerics

26 x 10

5x7

Half-width

20 x 5

8 x 16

Full-width

10 x 5

16 x 16

Calendar Clock

Year, month, day, hour, minute, and second with compensation for leap years

Reading Confirmation LED

Colors:

146

Red and green

Page 157

Appendices

[ 2 ] Bar Code Specifications (1)

Available Bar Code Types Bar Code Type

Readable Range

Bar Dimension

0.8-2.0 magnifications

0.26-0.66 mm (10.24-25.98 mils)

2-digit add-on

0.8-1.6 magnifications

0.26-0.55 mm (10.24-21.65 mils)

5-digit add-on

0.8-1.4 magnifications

0.26-0.46 mm (10.24-18.11 mils)

2-digit add-on

0.8-2.0 magnifications

0.26-0.66 mm (10.24-25.98 mils)

5-digit add-on

0.8-1.7 magnifications

0.26-0.57 mm (10.24-22.44 mils)

2-digit add-on

0.8-1.6 magnifications

0.26-0.55 mm (10.24-21.65 mils)

5-digit add-on

0.8-1.4 magnifications

0.26-0.46 mm (10.24-18.11 mils)

2-digit add-on

0.8-2.0 magnifications

0.26-0.66 mm (10.24-25.98 mils)

5-digit add-on

0.8-1.9 magnifications

0.26-0.63 mm (10.24-24.80 mils)

Universal product codes EAN-13 EAN-8 UPC-A UPC-E EAN-13 with supplemental codes

EAN-8 with supplemental codes

UPC-A with supplemental codes

UPC-E with supplemental codes

Interleaved 2 of 5 (ITF)

2 to 56 digits*

Standard 2 of 5 (STF)

1 to 32 digits

CODABAR (NW7)

3 to 36 digits

CODE39

1 to 29 digits

CODE93

1 to 42 digits

CODE128

1 to 35 digits

0.17 mm min. (6.69 mils min.)

* Only even-numbered digits

147

Page 158

(2)

(3)

Optical Properties Required for Bar Code Labels White bars: Reflection intensity

0.45 min.

Black bars:

Reflection intensity

0.25 max.

PCS value

0.45 min.

Bar Code Label Size Width : 15 mm min. (0.59 inch) (recommended)

Length :

Depth of field

Length of labels

(Distance from bar codes to the bar-code reading window)

(including margins)

0 mm

80 mm max. (3.15 inches max.) (Minimum narrow bar width: 0.17 mm min.*)

310 mm (12.21")

400 mm max. (15.75 inches max.) (Minimum narrow bar width: 1.4 mm min.**)

Length

Width

(4)

123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890

Thickness of Bars and Depth of Field Minimum narrow bar width

Depth of field

0.17 mm (6.69 mils) 0.25 mm (9.84 mils) 0.6 mm (23.62 mils) 1.0 mm (39.37 mils) 1.2 mm (47.24 mils)

10 mm (0.39 in.)* 45 mm (1.77 in.)* 130 mm (5.12 in.)** 220 mm (8.66 in.)** 260 mm (10.24 in.)**

* Under the following conditions: • Ambient illuminance: 500 lux. (fluorescent lamp) • 20-digit ITF • PCS value: 0.9 min. ** Under the following conditions: • Ambient illuminance: 500 lux. (fluorescent lamp) • ITF conforming to the UPC Shipping Container Code • PCS value: 0.9 min.

148

Page 159

Appendices

[ 3 ] Interface Specifications Optical Interface Synchronization:

Start-stop

Input signals:

RD and CS

Output signals:

SD and RS

Transmission speed:

19200 bps max.

Direct-connect interface Synchronization:

Start-stop

Transmission speed:

38400 bps max.

Signal level:

Conforms to RS-232C interface

Pin assignment:

As shown below.

2

4

6

8

1

3

5

7

Direct-connect Interface Port (QM connector) on the BHT-4000

Signal Input/Output

Pin No.

Signal

Functions

1

SD (GND)

Ground for signals and charging pin, 2

SD

Send data

→

3

RD

Receive data

←

4

RS

Request to send

→

5

CS

Ready to send

←

6

CD

Carrier detect

←

7

ER

Data terminal equipment ready

→

8

CHG

Charging pin

←

149

Page 160

A.2

CU-4000

[ 1 ] Product Specifications Power Source

12 VCD (via the AC adapter)

Power Consumption

2W

Dimensions (W) x (L) x (H)

106 x 236 x 89 mm (4.17 x 9.29 x 3.50 inches)

Weight

Approx. 420 g (Approx. 14.8 oz.)

Operating Ambient Temperature

0˚C to 40˚C (32˚F to 104˚F)

Operating Humidity

10% to 90% (with no dew condensation)

[ 2 ] Charging/Discharging Requirements

For charging a battery cartridge loaded in the BHT-4000 Charge current: Charge time:

80 mA Approx. 8 hours

For charging a battery cartridge all by itself Charge current: Charge time: Discharge current: Discharge time:

80 mA Approx. 8 hours 180 mA Approx. 2 hours

150

Page 161

Appendices

[ 3 ] Interface Specifications 13

1

25

14

RS-232C interface port (Dsub-25S) on the CU-4000

Pin No.

Signal

Functions

Signal Input/Output CU-4000 External device

2

SD

Send data

→

3

RD

Receive data

←

4

RS

Request to send

→

5

CS

Ready to send

←

7

SG

Signal ground, 20

ER

Data terminal equipment ready

→

Pins 1 (FG), 6 (DR), and 8 (CD) are not connected.

151

Page 162

Appendix B. A Typical Basic Operation What follows is a typical basic operation which helps you instruct the hands-on user in practical bar-code reading operation. Application type: Operation:

Inventory

Power ON

Execution program:

Read the bar code on stock (A). Key in the quantity. Read the bar code .. on stock (B). Key in the quantity. . Repeat the above. operation. .. Easy Pack 4.2

6. Ready for data entry Record 00100 scrolls up so that record 00101 becomes ready for next data entry.

==cáäÉN===ONJMVJVP ==^W =====jriqf=h=MMNMN 4. Display of read data

==^WMMPNPOPNOMTUS ==_W =====jriqf=h=MMNMM

3. Bar code entry Bring the bar-code reading window to the bar code to be scanned and press the trigger switch.

2. Ready for data entry

==cáäÉN===ONJMVJMP ==^W

5. Quantity entry Enter the quantity by pressing the numerical keys, then press the ENT key.

=====jriqf=h=MMNMM

==^WMMPNPOPNOMTUS ==_WOM 1. Power ON Press the PW key to turn on the power.

=====jriqf=h=MMNMM

152

Page 163

Bar Code Handy Terminal BHT-4000 User's Manual First Edition, October 1993 DENSO WAVE INCORPORATED The purpose of this manual is to provide accurate information in the handling and operating of the BHT-4000. Please feel free to send your commends regarding any errors or omissions you may have found, or any suggestions you may have for generally improving the manual. In no event will DENSO WAVE be liable for any direct or indirect damages resulting from the application of the information in this manual.