Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 10

M-Class Mark II Operator's Manual, pages 61 to 70

Pages 61 to 70 of 100

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datamax M4206

Page 61

5 5..9 9 D Do ow wn nllo oa ad diin ng gF Fiirrm mw wa arre ea an nd dF Fo on nttss The operating programs and fonts for the printer are stored in Flash memory on the Main PCB. When program updates and/or new features are added, they can be downloaded to the printer as follows: 1.

Identify the new version for your model of printer from the Datamax-O’Neil Web site at www.datamax-oneil.com and download it onto your computer’s hard drive or a floppy disk.

2.

Ensure that the printer is connected to the host, (via parallel port only) and that the power is ‘On.’ Using the DOS copy command, enter: copy filename.dlf lpt1/b

(non-display printer firmware is .dlf extension)

Other programs (e.g., hyper-terminal and certain Windows® Driver programs) may also be used to download this file. light will flash during the download.

3.

The READY

4.

STOP Light will illuminate then the printer will Following a successful download, the perform a ‘cold reset.’ The previous printer setup will not be affected unless substantial firmware data structure changes have occurred. Print a Database Configuration Label to verify your new firmware version.

Following an unsuccessful download, the ERROR Light will illuminate then the printer STOP lights will be on during power-up will perform a ‘warm reset’ (both the READY and initialization). The original firmware will remain operational. If the printer fails to reset, toggle the power ‘Off’ and ‘On.’ Try re-sending the file to the printer. If the failure continues, check the following possible causes: An invalid or corrupted file is being downloaded - Ensure the file being downloaded is correct and applicable for your printer model. Possible communications error - Check the cable connection between the host and printer and ensure that a quality, shielded cable is used. Possible Flash memory problem - Call for service.

Processing TrueType Fonts (Display-equipped printers with SDIO/USB Host) To process TrueType fonts (.TTF) on an external module for use by the printer: 1.

Use Windows Explorer to download the font to a module.

2.

Install the module in the printer.

3.

Press the MENU button then select Printer Options.

4.

Select Modules and then Process File.

5.

Select the module ID and the font file.

6.

When prompted enter a 2 character font ID, and then the destination module ID.

7.

Ensure that your label formats use the same font ID as assigned in Step 5.

Chapter 5 – Maintenance and Adjustments

55

Page 62

Copying TrueType Fonts (Display-equipped printers with SDIO/USB Host) To copy TrueType fonts (.TTF) to an external module for use by the printer: 1.

Use Windows Explorer to download the font to the module.

2.

Add a 2 digit DPL font ID to the file name (50-99, 9A-9Z, 9a-9z) then change the file extension to .dtf (for example, arial50.dtf); see Scalable Font Downloading in the Class Series 2 Programmer’s Manual.

3.

Install the module in the printer.

4.

Ensure that your label formats use the same font ID as assigned in Step 2.

Removing Fonts (Display-equipped printers) When deleting a plug-in, all files contained within that directory will also be deleted; see Section 4.5, PRINTER OPTIONS / MODULES / DELETE FILE for details.

5 5..1 10 0

F e d o M elllsss))) de od Mo Fiille eH Ha an nd dlliin ng gM Me essssa ag ge ess (((DDDiiisssppplllaaayyy---EEEqqquuuiiippppppeeeddd M

Depending upon the module and operation selected, several messages are possible when using the file handling system: File Handling Messages Displayed Message

Description

Possible Solution(s)

FAILED

The copy or format request has failed.

Insufficient space exists to store the file or the module is protected - try storing to a different location. (If the problem persists, this could indicate a hardware problem.)

FILE EXISTS, OVERWRITE?

An existing file of the same name and type was found.

Select YES to overwrite or NO to exit.

MODULE PROTECTED

Formatting has been denied because the module is protected.

Unprotect the module.

Chapter 5 – Maintenance and Adjustments

56

Page 63

File Handling Messages (Continued) Displayed Message

Description

Possible Solution(s) Ensure the file is present: • Following a Print File request, this is normal when no files are available for printing (also note that some files will print only the file name);

NO FILES AVAILABLE

No associated files can be found to perform the requested action.

• Following a Process File request, this is normal when no files are available for processing (also note that some files may not display); or, •

NOT SUPPORTED

PROTECTED, COPY FILE?

Following a Copy File request, this is normal when no files are available for copying (also note that internal database files cannot by copied).

The file type requested is not supported.

Recheck the type of file requested for printing or processing, and ensure that it matches one of the available types for that function.

The file requested will be copied to a protected module.

Select YES to override protection and copy the file, or NO to exit. Format the module.

UNFORMATTED

The module is unformatted.

FORMAT MODULE will erase all data in the selected memory.

Chapter 5 – Maintenance and Adjustments

57

Page 64

Chapter 5 – Maintenance and Adjustments

58

Page 65

6

Troubleshooting

6 6..1 1 P Prro ob blle em mR Re esso ollu uttiio on n Should a problem arise, the information in this section will help you resolve it. The following table lists problems that may not necessarily generate an error condition. Items denoted with an asterisk (*) are only for display-equipped printers. Try this solution…

If experiencing this problem… Can not communicate through the parallel port:

Observe the Ready Indicator as the format is sent to the printer. If it does not flash, check the parallel cable type. Also, check the protocol and port settings between the printer and host. WARNING! Use extreme care. Turn ‘Off’ and unplug the printer before proceeding.

Can not load media through the optional cutter:

Ensure that the cutter is properly installed. Plug in and turn ‘On’ the printer. You should hear the cutter blade rotate and position itself properly. However, if the problem continues call for service.

* The LCD is blank, but the Ready Indicator is ‘On’:

The display contrast may set too low. Press and hold the MENU Key for 10 seconds or until the display reappears.

Erratic feeding:

The printer may require Calibration; see Section 3.5.

Erratic printing (instead of the label format, strange characters are printed):

Intellifont™ will not print:

• The printer may be in Hex Dump Mode; see Section 6.3.

• If using the serial port for communicating, check both the host and printer port settings; the printer may be set to eight data bits while the host is set to 7 (or vice versa).

Intellifont™ format is Little/Big Endian specific. The printer uses Big Endian. Refer to your font supplier for information.

• The Media Width Adjustment may be incorrectly adjusted; Light print on the right side (facing the printer) of the label:

see Section 5.3.

• The Printhead or Platen Roller may be dirty or worn; clean or call for service.

Chapter 6 – Troubleshooting

59

Page 66

Try this solution…

If experiencing this problem…

• Check the label format for character placement outside the dimensions of the label; all row/column values must allow enough space for the height/length of the characters and bar codes to be printed within the format size.

Missing information in the printed label:

• The available memory may have been exceeded by the memory requirement of the label format. Try reducing the memory allocated to either the internal module or scaleable font caches (non-display printers, see Section 3.4; display-equipped printers, see Section 4.5.)

• If using serial communications, ensure that the interface cable meets the requirements found in Section 2.1.

Missing print on left or right side of the label:

Information may be formatted outside the label dimensions. Check your software program label size. For displayequipped printers also check the values in the menu for Print Control / Column Offset and Print Control / Custom Adjustments / Column Offset; see Section 4.5.

• Verify that the AC power cord connection has been made No power (all indicator lights are ‘Off”):

at both the outlet and the printer; also, ensure the power switch is ‘On’.

• Verify that the AC outlet is functioning, or try moving the printer to another AC circuit.

• The AC cord may be damaged; replace it. • The line fuse may be blown; call for service.

Chapter 6 – Troubleshooting

60

Page 67

Try this solution…

If experiencing this problem…

Examine the used ribbon for an image: If there is an image on the used ribbon: Verify that the ribbon was properly loaded per Section 2.4. If properly loaded, the wrong coating configuration was used. (To verify the inked side, press the adhesive backing of a label against the ribbon surface. Ink will only lift from the coated side of the ribbon.) Clean the printhead (see Section 5.2); then replace the ribbon with the correct type for the printer, Section 2.4. Nothing is printing (labels advance normally, but no image is printed):

If there is no image on the used ribbon:

• Print any Internal Test Label (non-display printers, see

Section 3.1.2; display-equipped printers, see Section 4.4.) If an image printed, then check the protocol and port settings for both the printer and host. These must match.

• The heat setting may be too low. Make an adjustment in the software program or through the Front Panel.

• The media/ribbon combination may be incorrect. Contact a Media Representative.

• The printhead or printhead cable(s) may be loose; power ‘Off’ the printer then reconnect.

• Ensure that the printer is at READY. Nothing happens when trying to print using a software program:

• Observe the Front Panel, if the READY light does not flash as you send the format check the protocol and port settings between the printer and host.

• Ensure the interface cable meets the requirements found in Section 2.1.

Chapter 6 – Troubleshooting

61

Page 68

Try this solution…

If experiencing this problem…

• The printhead may need cleaning; see Section 5.2. • Adjust the Heat and Print Speed settings through the Front Panel or by host commands (non-display printers, see Section 3.4; display-equipped printers, see Section 4.5.)

• The media/ribbon combination may not be compatible; contact a Media Representative.

Poor print quality:

• The Media Width Adjustment may be incorrectly adjusted; see Section 5.3.

• The Platen Roller may be dirty or worn; clean or call for service.

• The Printhead Burn Line may need adjusting; see Section 5.4.

• Media Calibration may be needed; see Section 3.5. • The Media Sensor may be out of position; readjust the position; see Section 2.3.

Skips labels when printing:

• The format may be within 1/8 inch of the label’s trailing edge. Try reducing or moving the format slightly.

Unable to print rotated text:

The characters may be formatted outside the label dimensions. Ensure the row/column values provide enough room for the height of the characters or bar code to be printed. See the Class Series 2 Programmer’s Manual for details.

Chapter 6 – Troubleshooting

62

Page 69

6 6..2 2 F Fa au ulltt a an nd dW Wa arrn niin ng gM Me essssa ag ge ess (((DDDiiisssppplllaaayyy---eeeqqquuuiiippppppeeeddd ppprrriiinnnttteeerrrsss))) All printer functions are internally monitored. If a problem (Fault) or a potential problem (Warning) is detected, the Error Indicator will be illuminated. A corresponding message will be displayed. These messages, along with possible solutions, are described below.

Fault Messages: Fault Messages receive the highest display priority. If more than one fault is detected, the display will toggle between messages.

To return to normal operation after the printer enters a fault condition, the fault must be corrected and then the FEED Key must be pressed to clear the condition. Printer Fault Messages

Displayed Message

Description

Possible Solution(s)

The printer has detected a drop in the 24-volt power supply.

Try cycling the printer power ‘Off’ and ‘On’. If the fault does not clear, call for service.

The printer has detected an analog to digital circuit converter failure.

Try cycling the printer power ‘Off’ and ‘On’. If the fault does not clear, call for service.

The printer has detected a cutter mechanism fault.

WARNING! Use extreme care. Turn ‘Off’ and unplug the printer before proceeding.

Examine the cutter for obstructions and ensure that the cutter cable is properly installed. Plug in and turn ‘On’ the printer. Press the FEED Key. If the fault does not clear, call for service.

The printer has detected a Direct Memory Access failure.

Try cycling the printer power ‘Off’ and ‘On’. If the fault does not clear, call for service.

Consistently low sensor readings were detected.

Press any key to continue. Ensure that media was inserted in the media sensor during the appropriate calibration step; also ensure that the sensor is free of debris. Retry the calibration. If the problem persists, try the ‘Advanced Entry Calibration’; see Section 3.5.

Chapter 6 – Troubleshooting

63

Page 70

The text of this page cannot be shown here; see it in the PDF.