Page 41

INTERNAL MODULE D 1024 DEFAULT MODULE D G

The available modules may vary depending upon printer model and options.

SCALEABLE FONT CACHE 0511 KBytes

Sets the number of 1KB blocks (100 - 5120) allocated for the internal DRAM ‘D’ module, where: Is the Default Setting. Designates the memory module to be used for file storage when none are specified, where: Is the Default Setting (DRAM module). Flash module.

Configures the number of 1KB blocks (100 - 5120) allocated for the scaleable font engine, where: Is the Default Setting.

The available memory may vary depending upon printer model and options.

SINGLE BYTE SYMBOLS

Selects the code page used to print single byte fonts, including:

ARABIC-8 CYRILLIC

ISO 15: ITALIAN LEGAL

ISO 17: SPANISH ISO 11: SWEDISH

ISO 60: DAN/NOR DESKTOP ITC ZAPF DINGBAT/100 ITC ZAPF DINGBAT/200 ITC ZAPF DINGBAT/300 PS ITC ZAPF DINGBAT ISO 8859/1 LATIN 1 ISO 8859/2 LATIN 2

HP4000 ZAPF DINGBAT MATH-8 MACINTOSH PS-MATH PC-858 MULTILINGUAL MICROSOFT PUBLISHING PC-8 CODE PAGE 437 PC-8 D/N, CP 437N

SYMBOL TURKISH-8 PS TEXT UTF-8 ISO 4: UK ISO 6: ASCII VENTURA INTERNATIONAL VENTURA US

ISO 8859/5 LATIN 5 ISO 8859/10 LATIN 6 ISO 8859/7 LT/GK E7 ISO 8859/15 LATIN 9 ISO 8859/7 LT/GK EG ISO 8859/8 LATIN/HBR ISO 8859/8 LATIN/CYR ISO 69: FRENCH GREEK-8

PC-852 LATIN 2 PC-851 LATIN/GREEK PC-862 LATIN/ARABIC PI FONT PC-850 MULTILINGUAL (Default Setting) PC-864 LATIN/ARABIC PC-8 TK, CP 437T PC-1004 PC-775 BALTIC

VENTURA MATH WINDOWS 3.1 LATIN 1 WINDOWS LATIN/ARABIC AGFA TIDBITS WINDOWS 3.1 LATIN 2 WINDOWS LATIN/GREEK WINDOWS 3.1 LATIN 5 WINDOWS WINDOWS 3.0 LATIN 1

PC-8 GREEK ISO 21: GERMAN HEBREW-7 HEBREW-8

PTXT3000 NON-UGL, PI FONT ROMAN-8 ROMAN-9

WINDOWS LATIN/CYRIC WINDOWS 3.0 LATIN 5

Reference the Class Series 2 Programmer’s Manual for code page symbol set details.

Chapter 4 – Menu System

35

Page 42

DOUBLE BYTE SYMBOLS JIS SHIFT JIS EUC UNICODE GB BIG 5

Selects the optional ILPC code page used to print double byte fonts, where: Japanese Industry Standard Shift Japanese Industry Standard Extended UNIX Code Unicode (including Korean). Default setting. Government Bureau Industry Standard; Chinese (PRC) Taiwan encoded

Reference the Class Series 2 Programmer’s Manual for the code page symbol set details.

TIME AND DATE MEDIA COUNTERS ABSOLUTE COUNTER PRINTHEAD COUNTER RESETTABLE COUNTER RESET COUNTER PRINT CONFIGURATION

Sets the printer's time and date. Displays and controls various internal counters, where: Shows the total number of inches printed and the date the counter was set (nonresettable). Shows the total number of inches printed (not user-resettable). Shows the number of inches printed since the last reset (user-resettable). Returns the Resettable Counter to zero. Produces a Configuration Label using the printer's current database information. (To generate the label, shown here, press the RIGHT Button or the ENTER Key.)

(1) The information varies with the model, firmware version and installed options.

(2) To capture all the data, use media that is at least 2 inches (51 mm) wide and set the Label Width (in Media Settings) according to the width of your labels. (3) Menu settings that require a reset to become effective will be indicated with a section symbol (§), while bulleted (•) items denote host changes not yet saved.

CONFIGURATION LEVEL

Displays the hardware and software levels of the printer, where:

PRINTER KEY

This information is also provided on the Configuration Label.

Identifies the unique key number of the printer, in the form: vvvv-cwxx-yyyyyyzzz, where: - Represents the printer model number. - Represents the hardware/software feature level, where: - Represents the printer class. - Represents hardware feature level of the main board. - Represents the software feature level (10 = standard DPL, and 20 = Internal CG Times Font). Features are accepted up to this value, but increases beyond the range will require an authorization code. yyyyyy - Is the manufacturing date code. zzz - Is a unique time stamp. vvvv cwxx c w xx

APPLICATION VERSION BOOT LOADER

Displays the level, version number, and date of the application firmware.

UPGRADE PRINTER CODE UNLOCK FEATURE

Upgrades the software feature level of the printer.

Displays the version level and date of the boot loader.

Unlocks additional optional features within the printer. (An authorization code is required.)

Chapter 4 – Menu System

36

Page 43

SET FACTORY DEFAULTS FORMAT ATTRIBUTES TRANSPARENT

Returns the printer settings to the factory-programmed values (except CUSTOM ADJUSTMENTS and calibrations); or, if selected, to the Factory Setting File, where selecting YES at the prompt causes the configuration to be restored. Defines the manner in which overlapping text and graphics appear when printed, where: Intersecting text, images, and bar codes will be printed, for example:

XOR

Intersecting text, images, and bar codes will not be printed, for example:

OPAQUE

(Default Setting) Intersecting text, images, and bar codes will be printed by obliterating those formatted first, for example:

LABEL ROTATION ENABLED DISABLED IMAGING MODE MULTIPLE LABEL

SINGLE LABEL PAUSE MODE ENABLED DISABLED PEEL MODE ENABLED DISABLED SECURITY SELECT SECURITY DISABLED SECURE MENU MENU AND TEST ADVANCED MENU MODIFY PASSWORD

Allows the label format to be rotated 180 degrees before printing, where: Flips the format. Does not flip the format. (Default Setting) Determines the process used to format labels, where: Images multiple labels as memory permits to achieve the fastest throughput. If time-stamping labels, however, the indicated time will reflect the moment of imaging rather than the actual print time. (Default Setting) Images the next label only after the previous label has been printed, providing the most accurate time-stamps but at a slower throughput rate. Allows for controlled interactive printing, where: Requires you to press the PAUSE Key to print each label. Labels are printed without pausing. (Default Setting) Allows the printer to wait until the Start of Print signal is received (via the optional GPIO Port) to feed a label, where: Inhibits the feed function until the Start of Print signal is received. Feeds the label regardless of the Start of Print signal. (Default Setting) Allows all or part of the User Interface to be password-protected and for that password to be modified: Allows password to be set for specific User Interface areas, where: No password is required for menu access. (Default Setting) Sets a password requirement for User and Advanced menu entry. Sets a password requirement for all menu entries. Sets a password requirement for Advanced menu entry. (After enabling this selection, make it effective by returning the Menu Mode to the User setting; see above.) Modifies the four-digit password required when security is enabled. For modification, the code must be reentered when prompted to confirm.

To be activated, the password must initially be set to a value other than the default setting (0000).

Chapter 4 – Menu System

37

Page 44

UNITS OF MEASURE IMPERIAL METRIC INPUT MODE DPL LINE PL-Z

DPL Emulation; SOP Emulation; and, Label Store. Identifies then activates the appropriate emulation parser for the data.

AUTO

Sets the measurement standard used, where: Uses inches. (Default Setting) Uses millimeters and centimeters. Defines the type of processing that will occur when data is received, where: Datamax-O’Neil programming language processing will be used. (Default Setting) Line Mode processing will be used, where data terminated by a carriage return will be extracted and inserted for template printing. Alternative programming language processing will be used, with the exception of the following DPL specific-parameters:

Correct identification can be dependant upon HOST SETTINGS / HOST TIMEOUT (see Section 4.2.5). Also, extraneous characters may, in some cases, render the data unrecognizable, thus requiring manual selection of the desired mode.

USER LABEL MODE ENABLED

Sets the printer to power-up as default, where: Functions in standalone mode for quick access to user defined formats; see Section 3.6.

DISABLED DPL EMULATION STANDARD ALLEGRO PRODIGY PLUS PRODIGY

This mode will remain active until disabled.

Functions in normal mode, awaiting commands from a host. Allows the printer to reproduce, for backward compatibility, label formats with the same characteristics as those produced by legacy models, where: Standard DPL processing will be used for printing. (Default Setting) Processes DPL data as an Allegro®, including row position calculations based on 194 dots per inch and the exceptions noted below. Processes DPL data as a Prodigy Plus®, including column calculations based on 200 dots per inch and the exceptions noted below. Processes DPL data as a Prodigy®, including column calculations based on 200 dots per inch and the exceptions noted below. Exceptions:

Data Terminator processing – When printing I 2 of 5 bar codes D, J, and L, the first non-numeric character processed will terminate the bar code data field. Bar Size exception – When printing I 2 of 5 bar code L, if the bar size specified is greater than P (25) it is automatically decreased to 10. Human Readable Fonts fixed size – When printing EAN and UPC bar codes B, C, F, G, M, and N, a fixed font size is produced. Line and box vertical sizing anomaly – When printing rotations 2 and 4, lines and boxes are affected by the vertical multiplication factor defined in the DPL Dxx command. Column position defaults – Column positions greater than the printhead width are adjusted back to the printable area then printed. Bar codes in rotation 3 - (upside down / right to left) default sizing – When row position in rotation 3 is less than bar code height, bar codes falling off the label's leading edge are pushed back onto the label. <STX>L command – When no printable fields reside in the format, it results in no label movement.

Chapter 4 – Menu System

38

Page 45

COLUMN EMULATION

Allows the column dots per inch to be adjusted (153 - 203 dots), so that numbers smaller than the printhead resolution reduce the printed output from right to left, where:

XXX Dots ROW EMULATION

XXX Dots SOP EMULATION DISABLED 110 (PRODPLUS) 220 (ALLEGRO) 250 (PRODIGY)

Allows the row dots per inch to be adjusted (103 - 303), so that numbers smaller than the printhead resolution enlarge the height of the printed output and numbers larger reduce it, where: Allows label positioning commands to function with backward compatibility when printing label formats designed for legacy models, where: Produces the natural start of print position. (Default Setting) Emulates the Prodigy Plus® start of print position. Emulates the Allegro® start of print position. Emulates the Prodigy™ start of print position.

When changing these values, the printer will automatically feed two labels to establish the new print position.

BACK AFTER PRINT MODE DISABLED ENABLED BACKUP DELAY (1/50s) 000 FONT EMULATION STANDARD FONTS CG TIMES USER ID S50 LABEL STORE STATE & FIELDS FIELDS ONLY MENU LANGUAGE ENGLISH DISPLAY SETTINGS

Determines media movement when a cutter, present sensor, peel and present, or GPIO is enabled, where: Repositions media, where: Movement occurs only when the next label is ready to print, minimizing edge curling. (Default Setting) Movement occurs according to BACKUP DELAY timing after a cut, cleared sensor, or SOP to allow fastest throughput. Instructs the printer to retract a presented label after a specified time elapses (0 – 255, in one-fiftieth of a second increments), where: Retraction occurs when the next label is received and processed. (Default Setting) Allows font substitution for all internal fonts (see examples), where: Prints using a standard (internal) font. (Default Setting) Prints using the CG Times font. Prints using a downloaded font. Determines the command recall level used when retrieving stored label formats, where: Recalls the printer state (i.e., heat, speed settings, etc.) and the label-formatting commands for the stored label. (Default Setting) Recalls the label-formatting commands for the stored label. Selects the menu and configuration label language. Only languages that are resident will be displayed (see Appendix D), where: Enables English (Default Setting) Determines the appearance of the items in the display, where:

GRAPHIC DISPLAY MODE STANDARD

Is the normal setting.

ENHANCED DISPLAY UNITS STANDARD IMPERIAL METRIC

Is the enlarged setting. Determines the displayed type of distance information, where: Displays the information according to the UNITS OF MEASURE setting (see above). Displays the information in inches. Displays the information in millimeters and centimeters.

Determines the magnification of the displayed items, where:

Chapter 4 – Menu System

39

Page 46

FAULT HANDLING LEVEL NO REPRINT

STANDARD

VOID AND RETRY

Determines the intervention required and the disposition of the label in process when a fault occurs, where: Selects the user action and the reprint status upon declaration of a fault, where: Printing stops and a fault message is displayed. Following correction of the problem, the FEED Key must be pressed to clear the fault, but the label in process is not reprinted. Printing stops and a fault message is displayed. Following correction of the problem, the FEED Key must be pressed to clear the fault then the label in process is reprinted. (Default Setting.) Depending upon the RETRY COUNT (see below), one of the following occurs: If the count has not been exceeded, VOID is printed (see VOID DISTANCE) on the failed label and reprinting automatically occurs; If the count has been exceeded, printing stops and a fault message is displayed. Following correction of the problem, the FEED Key must be pressed to clear the fault before the label in process is reprinted; or, If the CANCEL Key is pressed, reprinting is optional: to reprint press NO; or, to cancel the reprint press YES (and press YES again to cancel the batch.)

(1) With no Linear Scanner attached, the printer will perform in the STANDARD setting, except that VOID will be printed on the faulted label. (2) VOID will not be printed if insufficient text space exists (see VOID DISTANCE, below), or if the fault occurred after printing. (3) The text can be customized, see the Class Series 2 Programmer’s Manual for details.

VOID RETRY & CONT.

VOID is printed on a faulted label, with reprint attempts occurring automatically, until the RETRY COUNT has been exceeded and then that label will be skipped (discarded) and printing will continue to the next label in queue.

VOID DISTANCE (0.10 – 2.00 in.) 0.50 RETRY COUNT (0 – 3) 1

Sets the distance to backup and then print VOID on a faulted label, where: Is the distance, measured from the trailing edge of the label, which indirectly establishes the font size of the text. (The default setting is 0.5 inches.) Sets the number of reprint attempts, where: Is the last label in the count to be voided before the printer will stop and display a fault message. (The default setting is one.)

BACKFEED ON CLEAR ENABLED DISABLED

Retry counts greater than 1 are only valid for printers equipped with the Linear Scanner or RFID option.

Determines the printer's action after a fault is cleared, where: Backup label positioning will occur after the fault is cleared. No backup label positioning will occur after fault clearing; the printer will assume that the current position is correct. (This is the default setting.)

SCL FONT BOLD FACTOR 08 (1 – 36)

Linear Scanner or RFID required.

If reloading media, the label must be placed its presented position.

Sets a scalable font boldfacing amount, where: Is the setting, based on an incrementing scale, where eight (08) is nominal.

Chapter 4 – Menu System

40

Page 47

Communications The Communications menu contains interface and host control functions: Serial Port A Parallel Port A NIC Adapter (Ethernet) Host Settings The menu selections are defined as follows: DISPLAYED ITEM SERIAL PORT A BAUD RATE (1200 – 115000 BPS) 9600 BPS PROTOCOL BOTH SOFTWARE HARDWARE NONE PARITY NONE ODD EVEN DATA BITS (7 - 8) 8 STOP BITS (1 - 2) 1 PARALLEL PORT A PORT DIRECTION UNIDIRECTIONAL BIDIRECTIONAL

ITEM DESCRIPTION Controls the RS-232 communications settings for Serial Port A, where: Sets the serial communication rate, where: Is the range, in Bits Per Second; and, is the Default Setting. Sets the data flow control (handshaking) method, where: XON/XOFF and CTS/DTR are used. (Default Setting) XON/XOFF is used. CTS/DTR is used. Flow control is not used. Sets word parity, where: Parity is not used. (Default Setting) Odd parity is used. Even parity is used. Sets word length, where: A seven or eight bit word is selectable; and, is the Default Setting. Sets the number of stop bits, where: One stop or two stop bits are selectable; and, is the Default Setting. Controls the communication setting for the parallel port, where: Determines if data is returned from the printer, where: No data is returned; communication is one-way. Data is returned in compliance with IEEE 1284 back-channel operation. (Default Setting)

NIC ADAPTER

Controls the communications settings for the network interface, where:

QUICK SETUP WIRED DHCP WLAN UNSECURED WLAN ADHOC SET FACTORY DEFAULTS

An IEEE 1284 bidirectional cable is required.

If a wireless card is installed, this port is automatically disabled; to enable the wired LAN connection, disable the Wireless Ethernet MODE setting (see below).

Controls the communications settings for the network interface, where: Configures the card for wired connection. Configures the card for wireless connection, with SSID of “any” Configures the card for wireless connection, AdHoc mode. Resets NIC Adapter parameters to the factory defaults values.

Chapter 4 – Menu System

41

Page 48

WLAN MODE ENABLED DISABLED BSS ADDRESS SIGNAL READINGS IP ADDRESS SUBNET MASK GATEWAY SNMP TRAP DESTINATION IP DISCOVERY ENABLED

Controls the communications settings for the network interface, where: Selects between wired and wireless operation, where: Enables the wireless interface. (This is the Default Setting.) Enables the wired interface. Specifies the radio module’s static IP address; up to four octets separated by a period. If Enable DHCP is checked, this parameter is ignored. Default is 0.0.0.0. Provides a graphical representation of Signal Strength (in dBm), Noise Level (in dBm), and Quality. Specifies the static IP Address of the interface in the standard octet format. Specifies the static Subnet assigned to the interface, for example: 255.255.255.000. Specifies the Gateway Address the interface will use, for example: 010.001.001.001. Specifies the network IP Address where SNMP traps will be sent when SNMP service is installed on your receiver. If zeroed, no traps are sent. Sets the address discovery method, where: The card broadcasts over the network to receive addresses from the responsible server at startup. Manual modifications to IP Address, Subnet Mask, or Gateway Address are not allowed; and, if no server is found, the specified static value will be used. (Default Setting)

DISABLED SNMP ENABLED DISABLED ADVANCED TELNET FTP MTU

A server assigned IP address takes precedence over any static IP address stored in the interface.

The stored static IP, Subnet Mask, and / or Gateway Address will be used. Sets SNMP (Default Setting) Advanced settings for the NIC Card. Enable/Disable Telnet protocol Enable/Disable FTP protocol Sets the Maximum Transmission Unit packet size, where: Packet size, in bytes. (512-65515); Default is 1500

GRATUITOUS ARP TCP KEEPALIVE

Sets time interval for ARP transmission packets, where: (0-2048 minutes); Default is 0 Allows monitoring of an open connection to detect any disconnects not properly closed, including reset access points and unplugged printers, where:

ENABLED

Keeps monitoring active.

DISABLED

Closes such a disconnection after 2.5 minutes. (Default Setting)

PORT NUMBER DUPLEX CAPABILTY

Selects the Port to use for all network communications; Default is 9100 Specifies the transmission and speed of the wired Ethernet connection:

• • • • • ADVERTISE CAPABILITY

NETWORK REPORT SET FACTORY DEFAULTS

Auto-Negotiate (default); 100 BaseT Full Duplex; 100 BaseT Half Duplex; 10 BaseT Full Duplex; or, 10 BaseT Half Duplex

Selects the method in which the Duplex Capability setting is advertised, where:

• •

Automatic (advertises the DUPLEX CAPABILITY setting); or,

All Capabilities (advertises all capabilities) Prints or displays a report which lists the printer’s network settings. Resets NIC Adapter parameters to the factory defaults values.

Chapter 4 – Menu System

42

Page 49

HOST SETTINGS

Controls the communications with a host device, where:

HOST TIMEOUT

Sets the number of seconds (1 - 60) that an established communications port must be idle before data can be received through an alternate port, where:

10 CONTROL CODES STANDARD CODES ALTERNATE CODES ALTERNATE CODES 2

CUSTOM CODES FEEDBACK CHARACTERS ENABLED DISABLED ESC SEQUENCES ENABLED DISABLED HEAT COMMAND ENABLED DISABLED SPEED COMMANDS ENABLED DISABLED TOF SENSING COMMANDS ENABLED DISABLED SYMBOL SET COMMAND ENABLED DISABLED CNTRL-CODES (DATA) ENABLED DISABLED

The "ignore host" settings for ESC SEQUENCES, HEAT, SPEED, TOF SENSING, SYMBOL SET, CNTRL-CODES, STX-V SW SETTINGS, and MAX LENGTH will be unaffected when PL-Z Mode is selected (see Input Mode for details).

If the time-out period is exceeded before all data is received, the data will be ignored.

Is the Default Setting. Allows changes to the prefix of the software commands interpreted by the printer, where: Use these characters: Hex 01 = SOH command; Hex 02 = STX command; count-by = ^; Hex 1B = ESC; Hex 0x0D = Carriage Return. (Default Setting) Use these characters: Hex 5E = SOH command; Hex 7E = STX command; count-by = @; Hex 1B = ESC; Hex 0x0D = Carriage Return. Use these characters: Hex 5E = SOH command; Hex 7E = STX command; count-by = @; Hex 1B = ESC; Hex 0x7C = Carriage Return. Each DPL command (SOH, STX, CR, and count-by) may be selected by entering the desired Hex code. Allows the printer to return a Hex 1E (RS) after each label successfully prints, and a Hex 1F (US) after each label batch successfully prints, where: Sends feedback characters to the host. Does not send feedback characters to the host. (Default Setting) Allows data containing invalid ESC control code sequences to be processed, where: Processes commands normally. (Default Setting) Ignores ESC sequences are during processing (since some systems send a “banner” to the printer). Bitmapped font downloads are disabled in this mode. Determines the way the DPL Heat command is handled, where: Processes commands normally. (Default Setting) Ignores DPL Heat commands; instead, the heat value is controlled via the menu setting. Determines the way DPL Print, Feed, Slew, and Reverse commands are handled, where: Processes commands normally. (Default Setting) Ignores DPL speed commands; instead, the speeds are controlled via the menu setting. Determines the way in which DPL Gap, Continuous, and Reflective commands are handled, where: Processes commands normally. (Default Setting) Ignores DPL TOF commands; instead, TOF is controlled via the menu setting. Determines the way in which DPL Single and Double Symbol Set commands are handled, where: Processes commands normally. (Default Setting) Ignores DPL Symbol Set commands; instead, the Symbol Set selection is controlled via the menu setting. Determines the way in which DPL SOH, STX, CR, ESC, and ^ codes are handled, where: Processes commands normally. (Default Setting) Ignores DPL Control Codes; instead, the control code functions are established via the menu setting.

Chapter 4 – Menu System

43

Page 50

STX-V SW SETTINGS ENABLED DISABLED MAX LENGTH COMMAND ENABLED DISABLED OPTION FEEDBACK

Determines the way in which the DPL <STX>V command is handled, where: Processes commands normally. (Default Setting) Ignores the option-enable command; instead, the option selections are controlled via menu settings. Determines the way in which the DPL <STX>M command is handled, where: Processes commands normally. (Default Setting) Ignores the maximum label length command; instead, Maximum Label Length is controlled via the menu setting. Allows feedback characters from an optional device to be returned to the host device, in the format of: <A;B;C;D;E;F>[CR] Where:

DISABLED SCANNER RFID HEX RFID ASCII PROCESS SOH (DATA) ENABLED DISABLED

A-

Is the device type: R = RFID; and, S = Linear Scanner

B-

Is the resulting status: C = entire label complete; F = faulted (failed) label; and, U = unknown

C-

Is the number of expected reads, given in two characters.

D-

Is the number of good reads, given in two characters.

E-

Is the internal Job and Sub Job Identifier, given in four characters each.

F -

Is the data that was read, delimited with semicolons (;) on multiple reads.

No data is reported. (Default Setting) Linear Scanner information is reported. RFID information is reported in hexadecimal format. RFID information is reported in an ASCII format. Determines the way the printer responds to an Immediate Command (e.g., Get Status, Module Storage, etc.), where: Operations are interrupted upon receipt to process the command. Processes commands normally. (Default Setting)

Chapter 4 – Menu System

44