Page 11
1
Overview
1.1 About the Printer Congratulations on your purchase of an I-Class printer (hereafter referred to as “the printer”). This manual provides information regarding printer setup, operation, and care. To print label formats, refer to the instructions provided with your labeling software; or if you wish to write custom programs, a copy of the Class Series 2 Programmer’s Manual can be found on the Accessories CD and at our web site at http://www.datamaxcorp.com As detailed below, each model offers many standard and optional features to meet all your label generation needs.
1.1.1 Standard Features The model number, located on the back of the unit, defines many of the printer’s standard features:
I-Class
1
Page 12
Standard Features I-Class Model Feature
4206
4208
4212
4308
4406
4604
Direct Thermal Printing
X
X
X
X
X
X
Fan-Fold Media Handling
X
X
X
X
X
X
1MB
1MB
2MB
2MB
2MB
2MB
Liquid Crystal Display
X
X
X
X
X
X
Media Tear Bar
X
X
X
X
X
X
Multi-Language Support
X
X
X
X
X
X
On-Demand and Batch Printing
X
X
X
X
X
X
Resolution (Dots Per Inch)
203
203
203
300
406
600
Rotating Media Hub
X
X
X
X
X
X
8MB
8MB
16MB
16MB
16MB
16MB
Scalable Font Engine
X
X
X
X
X
X
Serial & Parallel Ports
X
X
X
X
X
X
Flash Memory
SDRAM
1.1.2 Optional Features (available except as noted) The following optional features are offered for the printer:
Cutter, Light Duty A rotary mechanism that cuts material with a maximum thickness of .005 inches (.127 mm) in lengths as small as 1.25 inches (31.8 mm). An adjustable collection tray (200 label capacity) can also be added. Cutter, Standard Duty A rotary mechanism that cuts material with a maximum thickness of .010 inches (.254 mm) in lengths as small as 1.25 inches (31.8 mm). An adjustable collection tray (200 label capacity) can also be added. DMXNetII and DMXrfNetII An internal wired or wireless Network Interface Controller for Ethernet connectivity with multiple operating system and protocol support, including trap functions.
2
I-Class
Page 13
External Keyboard (specify voltage & country requirement when ordering) A portable terminal for stand-alone printing.
External Media Rewinder (specify voltage requirement when ordering) A feature-dependant bidirectional label rewinding device:
•
DMXREW1 – rewinds widths up to 4.5 inches (114 mm) into eight-inch (203 mm) outer diameter rolls on one to four inch (25 to 101 mm) diameter cores at up to ten inches per second.
•
DMXREW2 – rewinds widths up to 9.5 inches (241 mm) into twelve-inch (304 mm) outer diameter rolls on a three-inch (76 mm) diameter core at up to thirty inches per second.
GPI/O Multi-Expansion Card A slide-in multi-feature circuit card:
•
Flash Memory Expansion – stores up to 8 MB of label formats, fonts, and graphics.
•
Real Time Clock – keeps the time and date for labeling functions.
•
GPIO Port – controls print functions via an external device (e.g., a label applicator).
•
ILPC Fonts (optional) – extends printing capabilities with CG-Times, Kanji Gothic B, Simplified Chinese GB, Korean Hangul scalable fonts.
•
MCL Serial Port (optional) – allows use with MCL application programs and firmware.
Internal Rewinder An internal device capable of rewinding six-inch (152 mm) outer diameter rolls of labels or backing material.
Linear Scanner (unavailable for I-4206; cannot be used with a cutter option) A CCD device that ensures the readability of bar codes. Peel and Present Mechanism (requires the Internal Rewinder option) A device that peels labels from the backing material for immediate application, regulated by previous label removal [minimum label length is 1.5 inches (38 mm)]. Present Sensor A device that regulates output to the removal of a previously printed label.
I-Class
3
Page 14
RFID An integrated Radio Frequency Identification tag encoding and reading device with data capture capabilities, available for immediate or future use:
•
Factory Installed – complete, ready to use.
•
Ready – factory installed antenna, requiring installation of additional hardware.
RS-422 Serial Interface (unavailable for I-4206 and I-4208 models) Single-drop interface hardware for greater printer to host serial communication distances (at up to 38,400 baud). Thermal Transfer (specify ribbon configuration at time of order) A device that allows the use of ribbon to produce exceptional image clarity (as compared to most direct thermal media). Twinax/Coax Interface A slide-in circuit card that provides connectivity to AS/400 and System/3X Twinax host systems or 3270-type host systems (cabling included). USB Port A slide-in circuit card that provides a Universal Serial Bus (Version 1.1) interface for Windows printing environments.
Option Installation Experience levels for option installations are detailed below. (Contact your dealer or Datamax Technical Support for more information.) Option Installations
4
Option
Recommended Installer
Cutters / Trays – Light or Standard Duty
Operator
DMXNetII or DMXrfNetII
DMX Certified Technician
External Keyboard
Operator
External Media Rewinder
Operator
GPI/O Multi-Expansion Card
DMX Certified Technician
Internal Rewinder
Operator
Linear Scanner
DMX Certified Technician
I-Class
Page 15
Option Installations (continued)
I-Class
Option
Recommended Installer
Peel and Present Mechanism
Operator
Present Sensor
Operator
RFID-Ready
DMX Certified Technician
RS-422 Serial Interface
DMX Certified Technician
Thermal Transfer
Operator
Twinax/Coax Interface
DMX Certified Technician
USB Port
DMX Certified Technician
5
Page 16
6
I-Class
Page 17
2
Getting Started
2.1 Unpacking the Printer The printer has been carefully packaged to prevent transit damage. (Inspect the container for damage; if evident, notify the shipping company before acceptance.) Complete the steps below to ready the printer for use:
A. With the arrow pointing upward, open the box.
B. Remove Accessories Box.
C. Tilt the box sideways and then slide out the printer.
D. Place the printer in an upright position and remove the packing foam, bag, and tape.
Note:
I-Class
Save the carton and packaging materials for future use.
7
Page 18
2.1.1 Inspection After removing the packaging, check the contents of the shipment. The following items should be included:
•
Printer
•
Power Cord
•
Accessories CD
•
Any special or additionally purchased items.
2.1.2 Additional Requirements Other items can also be needed for operation:
8
•
An interface cable; see Section 3.1.1.
•
Applicable media; see Section 7.3.
•
Applicable software; consult the Accessories CD-ROM and see Appendix E for details, or refer to your dealer or Datamax for information.
I-Class
Page 19
3
Setting up the Printer
3.1 Installation Interface and connect power to the printer: A. Place the printer on a firm, level surface. B. Turn OFF the Host Computer then, depending upon your system, connect an appropriate interface cable from the host to the printer; see Section 3.1.1. C. Turn ON the Host Computer. D. Ensure that the printer’s Power On/Off Switch is in the OFF position. Connect the AC Power Cord to the AC Power Connector, and then plug the AC Power Cord into a properly grounded AC Outlet.
Note:
I-Class
When interfacing, ensure AC power has been turned OFF, and always apply power to the Host before the Printer.
9
Page 20
3.1.1 Communications Following power-up (or after a period of inactivity), interface port selection occurs automatically upon detection of valid data. If the incoming (received) data flow stops and the Host Timeout Value (see Section 4.2.6) is exceeded, partially received formats will be ignored and the port detection process repeated. Notes:
1) To change an active port immediately, cycle the power OFF and ON. 2) For alternate data processing options, see SYSTEM SETTINGS / INPUT MODE - Section 4.2.5.
DMXNetII Network Interface Card / DMXrfNetII Wireless Network Interface Card The optional network interface has several menu-selectable modes; see Section 4.2.6 or refer to the manual provided with the option. Parallel Port The parallel interface has two menu-selectable modes of operation:
•
Unidirectional mode is forward channel communication and requires a Centronics cable with a 36 pin male connector.
•
Bidirectional mode is IEEE 1284 Compliant, using forward and reverse channel communications and requires an IEEE 1284 cable with a Centronics 36 pin male connector.
Serial Port The serial interface supports RS-232C, and if equipped optional RS-422 communications. The serial interface has menu-selectable settings that must match the host computer’s settings; see Section 4.2.6. In addition to the port settings, serial cable wiring must have specific pin connections for proper data flow; see Section 7.3. USB Interface Card The optional USB Port is plug and play interface, operating transparently and without menuselectable settings or modes.
WARNING
10
The USB Port is a device-end only connection. Never connect a keyboard, mouse, modem, etc. to this port; damage can result.
I-Class