The text of a manual · part 9 of 12
Viper-NET User's Manual: MAINTENANCE
Pages 53 to 58 of 71, from Viper-NET User's Manual
The original document is the PDF (4.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic Viper NET-300
Page 53
MAINTENANCE
4
4
MAINTENANCE
Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See par. 4.1. NOTE
4.1
CHARGING THE BATTERIES
The battery autonomy varies according to factors, such as the frequency of barcode scanning, RF usage, etc. When the batteries are low, the red LED positioned beneath the left lower corner of the display blinks and a warning acoustic signal is emitted. It is possible to recharge the batteries by using the FPS18 external power supply directly connected to either CAB-405 (for RS232 connection) or CAB-406 (for USB connection), see par. 2.1.1. Alternatively, it is also possible to recharge the batteries by using the CC9600 cradle. The charging process is signaled by a bi-colored charging status LED positioned beneath the right lower corner of the display (see par. 3.6.1). If the battery pack is removed from the terminal, it can be recharged by inserting it into the MBC9600 multi-slot battery charger.
NOTE
CAUTION
The battery pack autonomy varies according to many factors, such as the frequency of barcode scanning, RF usage, battery life, storage, environmental conditions, etc.
If the batteries are new or have not been recharged for a long time, it is necessary to perform two or three charging and discharging cycles (complete use) before they can reach their maximum charge capability. The maximum time required to recharge a completely run-down battery pack is about 5 hours for Li-Ion batteries.
35
Page 54
4
NOTE
36
VIPER-NET™
Even if the storage temperature range is wider, In order to achieve the longest battery life, store the terminal and the spare batteries between 20 to 30 ºC (68 to 86 ºF). The Batteries must be charged at a temperature ranging from 0° to +45 °C (+32° to +113 °F).
Page 55
MAINTENANCE
4.2
4
REPLACING THE BATTERIES
To correctly replace the batteries, proceed as follows. 1-
Turn off the Viper-NET™ terminal.
2-
Press the lock button as indicated in the figure below:
3-
Remove the battery pack by pulling down the lower part of the handle:
37
Page 56
4 4-
38
VIPER-NET™
Replace the battery pack, insert and press it back into the handle until the lock button is automatically closed:
Page 57
MAINTENANCE
4
Use only a Datalogic Mobile approved power supply. Use of an alternative power supply will void the product warranty and may cause product damage. Do not apply voltages to the batteries contacts. WARNING
Risk of explosion if the battery is replaced by an incorrect type. Do not use the batteries of this terminal to power devices different from this mobile computer. Do not place the battery in or near a fire or heat as they may explode. Do not place the battery in direct sunlight, or use or store the battery inside unventilated areas in hot weather. Doing so may cause the battery to generate heat, explode or ignite. Using the battery in this manner may also result in a loss of performance and a shortened life expectancy. Do not place the battery in microwave ovens, high pressure containers, or on induction cookware. Immediately discontinue use of battery if, while using, charging or storing the battery, the battery emits an unusual smell, feels hot, changes colour or shape, or appears abnormal in any other way. Do not short-circuit the battery contacts. Accidental short-circuiting can occur when a metallic object such as a coin, clip, or pen causes direct connection of the contacts of the battery (these look like metal strips on the battery). Do not carry or store battery pack together with metal objects (this might happen, for example, when you carry a spare battery in your pocket or purse). Short-circuiting the terminals may damage the battery or the connecting object. Do not pierce the battery pack with nails, strike it with a hammer, step on it or otherwise subject it to strong impacts or shocks. Do not solder directly onto the battery pack. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite. Do not expose the battery pack to liquids.
39
Page 58
VIPER-NET™
4
NOTE
In order to guarantee an adequate operating autonomy, when replacing the battery pack the terminal checks the battery energy level. If the battery is not sufficiently charged, Viper-NET™ does not turn on (when pressing the ON button). In this case, either substitute the battery pack with a charged one (sufficiently charged) or insert Viper-NET™ into a powered cradle or plug it into the direct power supply.
To achieve the best battery life, turn off the radios not in use. NOTE
4.3
CLEANING THE TERMINAL
Periodically clean the Viper-NET™ terminal with a slightly dampened cloth. Do not use alcohol, corrosive products or solvents.
40