Page 15
Chapter 2 Getting Started About the Imager Advancements in the LED technology used in this imager significantly improve the illumination of the target field of view, resulting in higher scan efficiency. Whether used in Single Trigger or Continuous Mode, the ergonomic design of the imager will help to promote comfortable handling during extended periods of use. The imager can communicate using the following interfaces: RS-232, The imager can communicate with a standard or Wincor-Nixdorf (W-N)
RS-232 host. RS-232 OPOS, This interface is used for OPOS/UPOS/JavaPOS systems. Keyboard Wedge (KBW), When connected using this interface, the host interprets scanned data as keystrokes and supports several international keyboards (for the Windows® environment). See Country Mode on page 68 for a full listing. USB, Select to communicate either by USB OEM, USB COM, USB Keyboard interface or USB POS types by scanning the appropriate interface type barcodes available in this manual. The default interface is USB-KBD for Wedge models (7230) and USBOEM for IBM models (7210). IBM, IBM Port 5B or Port 9B are selectable interface options. Wand Emulation, This interface produces an electrical signal that represents the bars and spaces of a label.
Unpacking Check carefully to ensure the imager and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Technical Support on page 3. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container.
Product Reference Guide
5
Page 16
Getting Started
Setting Up the Imager Follow the steps provided in this section to connect and get your imager up and communicating with its host: 1. Install the Interface Cable 2. Select the Interface Type 3. Configure Interface Settings (only if not using factory settings for that interface) 4. Configure Other Features (if modifications are needed from factory settings)
Install the Interface Cable The imager kit you ordered to match your interface should provide a compatible cable for your installation. If not, contact Technical Support. Seat the cable assembly into the imager, aligning both the connector, aligning the cable clip with its opening as shown in the insert portion of Figure 1. RS-232 Serial Connection, Turn off power to the terminal/PC and connect the imager to the terminal/PC serial port via the RS-232 cable as shown in Figure 1. If the terminal will not support POT (Power Off the Terminal) to supply imager power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet. Figure 1. Connecting the Interface Cable/RS-232 Connection
Connecting at the Imager Bottom of Imager
Cable Cable Strain Relief
To Host
Interface Cable Port
Cable Clip (Latch)
Disconnecting at the Imager Insert a paperclip into this hole to release the cable latch
Strain Relief Cable
Other connection types are described below and illustrated in Figure 2.
6
QuickScan® QD2100
Page 17
Setting Up the Imager
USB Connection, Connect the imager to a USB port on the terminal/PC using the correct USB cable for the interface type you ordered. Reference Figure 2. IBM Connection, Connect the imager to the IBM port on the terminal/PC using the correct IBM cable. Reference Figure 2. Keyboard Wedge Connection, The Keyboard Wedge cable has a ‘Y’ connection from the imager. Connect the female to the male end from the keyboard and the remaining end at the keyboard port at the terminal/PC. Reference Figure 2.
B
Figure 2. Other Interface Connections
US
M
Ke W or...
IB
NOTE yb ed oard ge or...
Specific cables are required for connection to different hosts. The connectors illustrated above are examples only. Actual connectors may vary from those illustrated, but the steps to connect the imager remain the same.
Programming The imager is typically factory-configured with a set of default features standard to the interface type you ordered. After scanning the interface barcode from the Interfaces section, you can select other options and customize your imager through use of the instructions and programming barcodes available in the corresponding features section for your interface and also the Data Editing and Symbologies chapters of this manual.
Product Reference Guide
7
Page 18
Getting Started
Using the Programming Barcodes This manual contains feature descriptions and barcodes which allow you to reconfigure your imager. Some programming barcode labels, like Resetting the Product Configuration to Defaults on page 9, require only the scan of that single label to enact the change. Most of the programming labels in this manual, however, require the imager to be placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT barcode once to enterProgramming Mode. Once the imager is in Programming Mode, you can scan a number of parameter settings before scanning the ENTER/EXIT barcode a second time, which will then accept your changes, exit Programming Mode and return the imager to normal operation. There are some exceptions to the typical programming sequence described above. Please read the description and setting instructions carefully when configuring each given programmable feature. NOTE
Select the Interface Type Upon completing the physical connection between the imager and its host, proceed directly to Interfaces on page 11 for information and programming for the interface type the imager is connected to (for example: RS-232, Keyboard Wedge, USB, etc.) and scan the appropriate barcode in that section to select your system’s correct interface type.
Configure Interface Settings The imager is typically factory-configured with a set of default features standard to the interface type you ordered. If after scanning the interface barcode from the Interfaces section, your installation requires you to select options to further customize your imager, turn to the appropriate section for your interface type as listed below: •
RS-232 ONLY Interface, starting on page 41
•
Keyboard Interface, starting on page 67
•
USB-OEM Interface, starting on page 81
•
IBM 46XX Interface, starting on page 85
•
Wand Emulation Interface, starting on page 91
Configure Other Features If your installation requires different programming than the standard factory default settings, the following sections of this manual allow configuration of non-interface-specific settings you might require: General Features, General Features includes programming for scanning, beeper and
LED indicators and other such universal settings. Symbologies, Includes options concerning the barcode label types (symbologies).
These settings allow you to enable/disable symbologies, set label lengths, require check digit, etc. 8
QuickScan® QD2100
Page 19
Resetting the Product Configuration to Defaults
Software Version Transmission The software version of the device can be transmitted over the RS-232 and Keyboard interfaces by scanning the following label.
Transmit Software Version
Resetting the Product Configuration to Defaults If you aren't sure what programming options are in your imager, or you've changed some options and want to restore the Custom Default Configuration that may have been saved in the imager, scan the Restore Custom Default Configuration barcode below. This will restore the custom configuration for the currently active interface.
Custom defaults are based on the interface type. Configure the imager for the correct interface before scanning this label. NOTE
Restore Custom Default Configuration
Product Reference Guide
9
Page 20
Getting Started
Resetting the Product Configuration to Defaults, cont. If you aren't sure what programming options are in your imager, or you've changed some options and want to restore the Factory Configuration, you have two options. You can scan the Restore USA Factory Configuration bar code or the Restore EU Factory Configuration bar code below. Both labels restore the imager configuration to the factory settings including the interface type. The USA label restores Label IDs to those historically used in the USA. The EU label restores Label IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the Label ID section of this manual.
Restore USA Factory Configuration
Restore EU Factory Configuration
The programming section lists the factory default settings for each of the menu commands (indicated by shaded blocks and bold text) on the following pages.