The text of a manual · part 27 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 201 to 210
Pages 201 to 210 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 201
Code 128
Code 128, cont. Code 128 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •
Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
•
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
•
Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
Product Reference Guide
191
Page 202
Symbologies
Code 128, cont. Code 128 Decoding Level, cont.
ENTER/EXIT PROGRAMMING MODE
Code 128 Decoding Level = 1
Code 128 Decoding Level = 2
DEFAULT Code 128 Decoding Level = 3
Code 128 Decoding Level = 4
Code 128 Decoding Level = 5
192
QuickScan® QD2100
Page 203
Code 128
Code 128, cont. Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Code 128 Length Control = Variable Length
Code 128 Length Control = Fixed Length
Product Reference Guide
193
Page 204
Symbologies
Code 128, cont. Code 128 Set Length 1 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 80). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODE 128 LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 23 for some examples of how to set this feature. Table 23. Code 128 Length 1 Setting Examples STEP
EXAMPLES
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 1 SETTING
4 5
194
ACTION
Scan Two Characters From
Appendix E, Keypad
01 Character
‘0’ and ‘1’
07 Characters
15 Characters
80 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘8’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
QuickScan® QD2100
Page 205
Code 128
Code 128, cont. Code 128 Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 128 Set Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
01 = Length 1 is 1 Character
195
Page 206
Symbologies
Code 128, cont. Code 128 Set Length 2 This feature specifies one of the barcode lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 80, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODE 128 LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 24 for some examples of how to set this feature. Table 24. Code 128 Length 2 Setting Examples STEP
EXAMPLES 00 (Ignore This Length)
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 128 LENGTH 2 SETTING
4 5
196
ACTION
Scan Two Characters From
Appendix E, Keypad
‘0’ and ‘0’
07 Characters
15 Characters
80 Characters
‘0’ and ‘7’
‘0’ and ‘F’
‘5’ AND 0’
Scan ENTER/EXIT PROGRAMMING MODE
QuickScan® QD2100
Page 207
Code 128
Code 128, cont. Code 128 Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 128 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
80 = Length 2 is 80 Characters
197
Page 208
Symbologies
Code 128, cont. Code 128 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Code 128 Character Correlation = Disable
Code 128 Character Correlation = Enable
198
QuickScan® QD2100
Page 209
Code 128
Code 128, cont. Code 128 Stitching This option enables/disables stitching for Code 128 labels. When parts of a Code 128 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
Code 128 Stitching = Disable
DEFAULT Code 128 Stitching = Enable
Product Reference Guide
199
Page 210
Symbologies
GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GTIN-128, UCC-128.)
GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: •
Transmit GS1-128 labels in Code 128 data format.
•
Transmit GS1-128 labels in GS1-128 data format.
•
Do not transmit GS1-128 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT GS1-128 = Transmit in Code 128 data format
GS1-128 = Transmit in GS1-128 data format
GS1-128 = Do not transmit GS1-128 labels
200