Page 11

Parts of the Imager

Parts of the Imager LED

Scan Window Trigger Nose Boot

Scanning Modes The imager can operate in one of several scanning modes: Trigger Single, When the trigger is pulled, scanning is activated until one of the following occurs: - a programmable duration1 has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum programmable duration1 has elapsed. Trigger Hold Multiple, When the trigger is pulled, scanning starts and the product scans until the trigger is released or a programmable duration1 has elapsed. Reading a label does not disable scanning. Double Read Timeout2 prevents undesired multiple reads while in this mode. Trigger Pulse Multiple, When the trigger is pulled and released, scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state. Double Read Timeout2 prevents undesired multiple reads while in this mode.

Flashing, The reader flashes3 on and off regardless of the trigger status. 1. 2. 3.

See the Product Reference Guide (PRG) for additional programmable features, in this case: Scanning Active Time. Double Read Timeout is also programmed using the PRG. Controlled by Flash On Time and Flash Off Time. Use the PRG to program these options.

Quick Reference Guide

3

Page 12

Always On, No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout1 prevents undesired multiple reads while in this mode. Stand Mode, No trigger pull is required to read a bar code. Scanning is turned on automatically when an item is placed in reader’s field of view. If the trigger is pulled, the reader acts as if it in Trigger Single mode. Double Read Timeout2 prevents undesired multiple reads while in this mode. Trigger Object Sense, This mode is similar to Stand Mode, except that a trigger pull is required to activate the decoder.

Scan Mode = Trigger Single

Scan Mode = Trigger Hold Multiple

Scan Mode = Trigger Pulse Multiple

1. 2.

4

Double Read Timeout is programmed using the PRG. Double Read Timeout is programmed using the PRG.

TM

QuickScan i

Page 13

Scanning Modes

Scanning Modes, continued

Scan Mode = Flashing

Scan Mode = Always On

Scan Mode = Stand Mode

Scan Mode = Trigger Object Sense

Quick Reference Guide

5

Page 14

Troubleshooting Problem

Possible Cause

Nothing happens when the scan button is pulled.

Possible Solutions

No power to the imager.

Check system power. Ensure power supply is connected.

Interface or power cables are loose.

Ensure all cable connections are secure.

Imager not proLED comes on, but bargrammed for correct code does not decode. barcode type.

Ensure imager is programmed to read the type of barcode scanned. Refer to the Product Reference Guide (PRG) for more information.

Barcode label is unreadable.

Check the label to ensure it is not defaced. Try scanning another barcode type.

Distance between imager and barcode is incorrect.

Move imager closer to or further from the barcode.

Barcode reading ability has degraded.

Scan Window has become scratched or contaminated with dust.

Replace window as instructed in this guide.

Barcode is decoded but not transmitted to the host.

Imager not programmed for the correct host type.

Scan the appropriate host type barcode. Refer to the Product Reference Guide (PRG) for more information.

For detailed troubleshooting, refer to the Product Reference Guide.

NOTE

6

TM

QuickScan i

Page 15

LED and Beeper Indications

LED and Beeper Indications The imager’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. A “Green Spot” also lights to indicate a good read. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming barcode labels. Reference the PRG for a more detailed list.

Indication

LED

Beeper

Power-up

LED flashes/blinks on power-up, however, this may be too rapid to view. With a USB interface, the LED blinks until enumeration with the host is completed.

Imager beeps four times at highest frequency and volume upon power-up.

Good Read

One beep at current freLED behavior for this indica- quency, volume, tion is configurable using the mono/bi-tonal setting and PRG. duration upon a successful label scan.

ROM Failure

200ms on / 200ms off

Imager sounds one error beep at highest volume for 200 mS.

Limited Scanning Label Read

N/A

Imager 'chirps' six times at the highest frequency and current volume.

Imager Disabled

The LED blinks continuously 100mS on / 900 mS off

N/A

Quick Reference Guide

7

Page 16

Programming Barcodes For your convenience, this guide includes the programming barcodes required to configure the imager for use with different interface (terminal/host) types. See the Product Reference Guide (PRG) for more complete information about programming and configurable features. You can download the latest version of the PRG and any other available publications for the imager from the website listed on the back cover of this manual. Resetting the Standard Product Defaults

If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Factory Default Settings barcode below. This will copy the factory configuration for the currently active interface to the current configuration.

Factory Default Settings Host Interfaces Cables may vary depending upon system configuration.

NOTE

8

Some interfaces require the imager to start in the disabled state when powered on. If additional imager configuration is desired while in this state, pull the trigger and hold it for five seconds. The imager will change to a state that allows programming with barcodes.

TM

QuickScan i

Page 17

Programming Barcodes

RS-232 Interface

To use an RS-232 interface, scan the barcode for the desired RS-232 host type.

Select RS-232 Standard

Select RS-232 Wincor Nixdorf

Select RS-232 OPOS (for use with OPOS/UPOS/JavaPOS) IBM Interface

Select IBM Port 5B

Select IBM Port 9B Quick Reference Guide

9

Page 18

USB Interface

The imager attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. When using a USB interface, the imager auto-detects the USB and defaults to the HID keyboard interface.

Select USB-COM-STD1 (simulates RS-232 standard interface)

Select USB Keyboard (with standard key encoding)

Select USB Alternate Keyboard (with alternate key encoding)

Select USB OEM

Select USB-KBD-APPLE (for Apple computers)

1.

10

Download the correct USB Com driver from www.datalogic.com.

TM

QuickScan i

Page 19

Programming Barcodes

Keyboard Wedge Interface

To use a Keyboard Wedge interface, scan the barcode for the desired keyboard type.

Select KBD-AT (AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding)

Select KBD-AT-NK (IBM AT PS2 with standard key encoding but without external kbd.)

Select KBD-AT-ALT (AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key)

Select KBD-AT-ALT-NK (for IBM AT PS2 with alternate key encoding but without external keyboard)

Quick Reference Guide

11

Page 20

Keyboard Wedge Interface, continued

Select KBD-XT (PC/XT w/Standard Key Encoding)

Select KBD-IBM-3153 (for IBM Terminal 3153)

Select KBD-IBM-M (for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard)

Select KBD-IBM-MB (for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard)

Select KBD-DIG-VT (for DIGITAL Terminals VT2xx, VT3xx, VT4xx)

12

TM

QuickScan i