QuickScan L QD 2300 Bar Code Scanner Product Reference Guide: Symbologies, pages 146 to 152
Pages 146 to 152 of 192, from QuickScan L QD 2300 Bar Code Scanner Product Reference Guide
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD-2300
Page 146
Symbologies
GS1 DataBar (RSS) The variants of GS1 DataBar are DataBar Omnidirectional, DataBar Expanded and DataBar Limited.
NOTE
The GS1 DataBar symbology family was formerly known as RSS. Equivalents for each variant in the family are: RSS-14 = DataBar Omnidirectional RSS Expanded = DataBar Expanded RSS Limited = DataBar Limited
DataBar Omnidirectional and DataBar Expanded include stacked versions. Scan the appropriate bar code below to enable or disable each variant of DataBar.
Enable DataBar Omnidirectional
*Disable DataBar Omnidirectional
Enable DataBar Limited
*Disable DataBar Limited
Enable DataBar Expanded
*Disable DataBar Expanded
140
QuickScan® L
Page 147
GS1 DataBar (RSS)
Convert DataBar to UPC/EAN This parameter only applies to DataBar Omnidirectional and DataBar Limited bar codes not decoded as part of a Composite bar code. Enable this to strip the leading '010' from DataBar Omnidirectional and DataBar Limited bar codes encoding a single zero as the first digit, and report the bar code as EAN-13. For bar codes beginning with two or more zeros but not six zeros, this parameter strips the leading '0100' and reports the bar code as UPC-A. The UPC-A Preamble parameter that transmits the system character and country code applies to converted bar codes. Note that neither the system character nor the check digit can be stripped.
Enable Convert DataBar to UPC/EAN
*Disable Convert DataBar to UPC/EAN
Product Reference Guide
141
Page 148
Symbologies
Symbology - Specific Security Levels Redundancy Level The scanner offers four levels of decode redundancy. Select higher redundancy levels for decreasing levels of bar code quality. As redundancy levels increase, the scanner’s aggressiveness decreases. Select the redundancy level appropriate for the bar code quality. Redundancy Level 1 The following code types must be successfully read twice before being decoded: Table 24. Redundancy Level 1 Code Types Code Type
Code Length
Codabar
8 characters or less
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Redundancy Level 2 The following code types must be successfully read twice before being decoded: Table 25. Redundancy Level 2 Code Types Code Type
Code Length
All
All
Redundancy Level 3 Code types other than the following must be successfully read twice before being decoded. The following codes must be read three times: Table 26. Redundancy Level 3 Code Types Code Type
142
Code Length
MSI
4 characters or less
D 2 of 5
8 characters or less
I 2 of 5
8 characters or less
Codabar
8 characters or less
QuickScan® L
Page 149
Symbology - Specific Security Levels
Redundancy Level 4 The following code types must be successfully read three times before being decoded: Table 27. Redundancy Level 4 Code Types Code Type
Code Length
All
All
*Redundancy Level 1
Redundancy Level 2
Redundancy Level 3
Redundancy Level 4
Product Reference Guide
143
Page 150
Symbologies
Security Level The scanner offers four levels of decode security for delta bar codes, which include the Code 128 family, UPC/EAN, and Code 93. Select increasing levels of security for decreasing levels of bar code quality. There is an inverse relationship between security and scanner aggressiveness, so choose only that level of security necessary for any given application. •
Security Level 0: This default setting allows the scanner to operate in its most aggressive state, while providing sufficient security in decoding most “in-spec” bar codes.
•
Security Level 1: Select this option if misdecodes occur. This security level should eliminate most misdecodes.
•
Security Level 2: Select this option if Security level 1 fails to eliminate misdecodes.
•
Security Level 3: If Security Level 2 was selected and misdecodes still occur, select this security level. Be advised, selecting this option is an extreme measure against mis-decoding severely out of spec bar codes. Selecting this level of security significantly impairs the decoding ability of the scanner. If this level of security is necessary, try to improve the quality of the bar codes.
*Security Level 0
Security Level 1
Security Level 2
Security Level 3
144
QuickScan® L
Page 151
Symbology - Specific Security Levels
Bi-directional Redundancy Enable Bi-directional Redundancy to add security to linear code type security levels. When enabled, a bar code must be successfully scanned in both directions (forward and reverse) before reporting a good decode.
Enable Bi-directional Redundancy
*Disable Bi-directional Redundancy
Product Reference Guide
145
Page 152
Symbologies
Symbology - Intercharacter Gap The Code 39 and Codabar bar codeogies have an intercharacter gap that is customarily quite small. Due to various bar code printing technologies, this gap may grow larger than the maximum size allowed, causing the scanner to be unable to decode the bar code. If this problem is encountered, scan Large Intercharacter Gaps to tolerate out-of-specification bar codes.
*Normal Intercharacter Gaps
Large Intercharacter Gaps
146
QuickScan® L