Page 101
Chapter 9 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 2, Getting Started. The scanner is shipped with the settings shown in Table 23 on page 96 (also see Appendix B, Standard Defaults for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner is powered down. If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the appropriate default bar code on page 21. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*Enable UPC-A
Feature/Option
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPCA Check Digit bar code under Transmit UPC-A Check Digit on page 104. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5, require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Product Reference Guide
95
Page 102
Symbologies
Symbology Parameter Defaults Table 23 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 99.
See Appendix B, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters. NOTE Table 23. Symbology Defaults Parameter
Default
Page Number
UPC-A
Enable
99
UPC-E
Enable
99
UPC-E1
Disable
100
EAN-8/JAN 8
Enable
101
EAN-13/JAN 13
Enable
101
Bookland EAN
Disable
101
Decode UPC/EAN/JAN Supplementals (2 and 5 digits)
Ignore
103
Decode UPC/EAN/JAN Supplemental Redundancy
7
104
Transmit UPC-A Check Digit
Enable
104
Transmit UPC-E Check Digit
Enable
105
Transmit UPC-E1 Check Digit
Enable
105
UPC-A Preamble
System Character
106
UPC-E Preamble
System Character
107
UPC-E1 Preamble
System Character
108
Convert UPC-E to A
Disable
109
Convert UPC-E1 to A
Disable
109
EAN-8/JAN-8 Extend
Disable
110
UCC Coupon Extended Code
Disable
110
Code 128
Enable
111
UCC/EAN-128
Enable
111
UPC/EAN
Code 128
96
QuickScan® L
Page 103
Symbology Parameter Defaults
Table 23. Symbology Defaults (Continued) Parameter
Default
Page Number
Enable
112
Code 39
Enable
112
Trioptic Code 39
Disable
113
Convert Code 39 to Code 32 (Italian Pharmacy Code)
Disable
113
Code 32 Prefix
Disable
114
Set Length(s) for Code 39
2 to 55
115
Code 39 Check Digit Verification
Disable
116
Transmit Code 39 Check Digit
Disable
116
Code 39 Full ASCII Conversion
Disable
117
Buffer Code 39
Disable
118
Code 93
Disable
120
Set Length(s) for Code 93
4 to 55
122
Code 11
Disable
122
Set Lengths for Code 11
4 to 55
124
Code 11 Check Digit Verification
Disable
125
Transmit Code 11 Check Digit(s)
Disable
126
Interleaved 2 of 5 (ITF)
Enable
126
Set Lengths for I 2 of 5
14
128
I 2 of 5 Check Digit Verification
Disable
129
Transmit I 2 of 5 Check Digit
Disable
129
Convert I 2 of 5 to EAN 13
Disable
130
ISBT 128 (non-concatenated) Code 39
Code 93
Code 11
Interleaved 2 of 5 (ITF)
Product Reference Guide
97
Page 104
Symbologies
Table 23. Symbology Defaults (Continued) Parameter
Default
Page Number
Disable
130
12
132
Disable
132
Codabar
Disable
133
Set Lengths for Codabar
5 to 55
134
CLSI Editing
Disable
135
NOTIS Editing
Disable
136
MSI
Disable
136
Set Length(s) for MSI
2 to 55
138
MSI Check Digits
One
138
Transmit MSI Check Digit
Disable
139
MSI Check Digit Algorithm
Mod 10/Mod 10
139
DataBar Omnidirectional (RSS-14)
Disable
140
DataBar Limited
Disable
140
DataBar Expanded
Disable
140
Convert DataBar to UPC/EAN
Disable
141
Redundancy Level
1
143
Security Levels
0
144
Disable
145
Discrete 2 of 5 (DTF) Discrete 2 of 5 Set Length(s) for D 2 of 5 Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Codabar (NW - 7)
MSI
GS1 DataBar (RSS)
Symbology - Specific Security Levels
Bi-directional Redundancy
98
QuickScan® L
Page 105
UPC/EAN
UPC/EAN Enable/Disable UPC-A/UPC-E To enable or disable UPC-A or UPC-E, scan the appropriate bar code below.
*Enable UPC-A
Disable UPC-A
*Enable UPC-E
Disable UPC-E
Product Reference Guide
99
Page 106
Symbologies
Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below.
UPC-E1 is not a UCC (Uniform Code Council) approved symbology. NOTE
Enable UPC-E1
*Disable UPC-E1
100
QuickScan® L
Page 107
UPC/EAN
Enable/Disable EAN-13/EAN-8 To enable or disable EAN-13 or EAN-8, scan the appropriate bar code below.
*Enable EAN-13
Disable EAN-13
*Enable EAN-8
Disable EAN-8
Enable/Disable Bookland EAN To enable or disable Bookland EAN, scan the appropriate bar code below.
Enable Bookland EAN
*Disable Bookland EAN
Product Reference Guide
101
Page 108
Symbologies
Decode UPC/EAN/JAN Supplementals Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. •
If Decode UPC/EAN/JAN Only With Supplementals is selected, UPC/EAN bar codes without supplementals are not decoded.
•
If Ignore Supplementals is selected, and the scanner is presented with a UPC/EAN/ JAN with a supplemental, the UPC/EAN/JAN is decoded and the supplemental bar code is ignored.
•
An Autodiscriminate Option is also available. If this option is selected, choose an appropriate value from the next page. A value of 5 or more is recommended.
•
Select Enable 378/379 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’ or ‘379’ prefix by the supplemental search process. All other UPC/ EAN/JAN bar codes are exempted from the search and are reported instantly upon decode.
•
Select Enable 978 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘978’ prefix by the supplemental search process. All other UPC/EAN bar codes are exempted from the search and are reported instantly upon their decode.
•
Select Enable Smart Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’, ‘379’, or ‘978’ prefix by the supplemental search process. All other UPC/ EAN bar codes are exempted from the search and are reported instantly upon their decode.
To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters. NOTE
102
QuickScan® L
Page 109
UPC/EAN
Decode UPC/EAN/JAN Supplementals (continued)
Decode UPC/EAN/JAN Only With Supplementals
*Ignore Supplementals
Autodiscriminate UPC/EAN/JAN Supplementals
Enable 378/379 Supplemental Mode
Enable 978 Supplemental Mode
Enable Smart Supplemental Mode
Product Reference Guide
103