Page 101

Chapter 9 Symbologies Introduction This chapter describes symbology features and provides the programming bar codes for selecting these features. Before programming, follow the instructions in Chapter 2, Getting Started. The scanner is shipped with the settings shown in Table 23 on page 96 (also see Appendix B, Standard Defaults for all host device and miscellaneous defaults). If the default values suit requirements, programming is not necessary. To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner is powered down. If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connected to a new host. To return all features to default values, scan the appropriate default bar code on page 21. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*Enable UPC-A

Feature/Option

Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to transmit bar code data without the UPC-A check digit, simply scan the Do Not Transmit UPCA Check Digit bar code under Transmit UPC-A Check Digit on page 104. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Set Length(s) for D 2 of 5, require scanning several bar codes. See the individual parameter, such as Set Length(s) for D 2 of 5, for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Product Reference Guide

95

Page 102

Symbologies

Symbology Parameter Defaults Table 23 lists the defaults for all symbologies parameters. To change any option, scan the appropriate bar code(s) provided in the Symbologies Parameters section beginning on page 99.

See Appendix B, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters. NOTE Table 23. Symbology Defaults Parameter

Default

Page Number

UPC-A

Enable

99

UPC-E

Enable

99

UPC-E1

Disable

100

EAN-8/JAN 8

Enable

101

EAN-13/JAN 13

Enable

101

Bookland EAN

Disable

101

Decode UPC/EAN/JAN Supplementals (2 and 5 digits)

Ignore

103

Decode UPC/EAN/JAN Supplemental Redundancy

7

104

Transmit UPC-A Check Digit

Enable

104

Transmit UPC-E Check Digit

Enable

105

Transmit UPC-E1 Check Digit

Enable

105

UPC-A Preamble

System Character

106

UPC-E Preamble

System Character

107

UPC-E1 Preamble

System Character

108

Convert UPC-E to A

Disable

109

Convert UPC-E1 to A

Disable

109

EAN-8/JAN-8 Extend

Disable

110

UCC Coupon Extended Code

Disable

110

Code 128

Enable

111

UCC/EAN-128

Enable

111

UPC/EAN

Code 128

96

QuickScan® L

Page 103

Symbology Parameter Defaults

Table 23. Symbology Defaults (Continued) Parameter

Default

Page Number

Enable

112

Code 39

Enable

112

Trioptic Code 39

Disable

113

Convert Code 39 to Code 32 (Italian Pharmacy Code)

Disable

113

Code 32 Prefix

Disable

114

Set Length(s) for Code 39

2 to 55

115

Code 39 Check Digit Verification

Disable

116

Transmit Code 39 Check Digit

Disable

116

Code 39 Full ASCII Conversion

Disable

117

Buffer Code 39

Disable

118

Code 93

Disable

120

Set Length(s) for Code 93

4 to 55

122

Code 11

Disable

122

Set Lengths for Code 11

4 to 55

124

Code 11 Check Digit Verification

Disable

125

Transmit Code 11 Check Digit(s)

Disable

126

Interleaved 2 of 5 (ITF)

Enable

126

Set Lengths for I 2 of 5

14

128

I 2 of 5 Check Digit Verification

Disable

129

Transmit I 2 of 5 Check Digit

Disable

129

Convert I 2 of 5 to EAN 13

Disable

130

ISBT 128 (non-concatenated) Code 39

Code 93

Code 11

Interleaved 2 of 5 (ITF)

Product Reference Guide

97

Page 104

Symbologies

Table 23. Symbology Defaults (Continued) Parameter

Default

Page Number

Disable

130

12

132

Disable

132

Codabar

Disable

133

Set Lengths for Codabar

5 to 55

134

CLSI Editing

Disable

135

NOTIS Editing

Disable

136

MSI

Disable

136

Set Length(s) for MSI

2 to 55

138

MSI Check Digits

One

138

Transmit MSI Check Digit

Disable

139

MSI Check Digit Algorithm

Mod 10/Mod 10

139

DataBar Omnidirectional (RSS-14)

Disable

140

DataBar Limited

Disable

140

DataBar Expanded

Disable

140

Convert DataBar to UPC/EAN

Disable

141

Redundancy Level

1

143

Security Levels

0

144

Disable

145

Discrete 2 of 5 (DTF) Discrete 2 of 5 Set Length(s) for D 2 of 5 Chinese 2 of 5 Enable/Disable Chinese 2 of 5 Codabar (NW - 7)

MSI

GS1 DataBar (RSS)

Symbology - Specific Security Levels

Bi-directional Redundancy

98

QuickScan® L

Page 105

UPC/EAN

UPC/EAN Enable/Disable UPC-A/UPC-E To enable or disable UPC-A or UPC-E, scan the appropriate bar code below.

*Enable UPC-A

Disable UPC-A

*Enable UPC-E

Disable UPC-E

Product Reference Guide

99

Page 106

Symbologies

Enable/Disable UPC-E1 UPC-E1 is disabled by default. To enable or disable UPC-E1, scan the appropriate bar code below.

UPC-E1 is not a UCC (Uniform Code Council) approved symbology. NOTE

Enable UPC-E1

*Disable UPC-E1

100

QuickScan® L

Page 107

UPC/EAN

Enable/Disable EAN-13/EAN-8 To enable or disable EAN-13 or EAN-8, scan the appropriate bar code below.

*Enable EAN-13

Disable EAN-13

*Enable EAN-8

Disable EAN-8

Enable/Disable Bookland EAN To enable or disable Bookland EAN, scan the appropriate bar code below.

Enable Bookland EAN

*Disable Bookland EAN

Product Reference Guide

101

Page 108

Symbologies

Decode UPC/EAN/JAN Supplementals Supplementals are bar codes appended according to specific format conventions (e.g., UPC A+2, UPC E+2, EAN 13+2). Six options are available. •

If Decode UPC/EAN/JAN Only With Supplementals is selected, UPC/EAN bar codes without supplementals are not decoded.

•

If Ignore Supplementals is selected, and the scanner is presented with a UPC/EAN/ JAN with a supplemental, the UPC/EAN/JAN is decoded and the supplemental bar code is ignored.

•

An Autodiscriminate Option is also available. If this option is selected, choose an appropriate value from the next page. A value of 5 or more is recommended.

•

Select Enable 378/379 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’ or ‘379’ prefix by the supplemental search process. All other UPC/ EAN/JAN bar codes are exempted from the search and are reported instantly upon decode.

•

Select Enable 978 Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘978’ prefix by the supplemental search process. All other UPC/EAN bar codes are exempted from the search and are reported instantly upon their decode.

•

Select Enable Smart Supplemental Mode to delay only EAN-13/JAN-13 bar codes starting with a ‘378’, ‘379’, or ‘978’ prefix by the supplemental search process. All other UPC/ EAN bar codes are exempted from the search and are reported instantly upon their decode.

To minimize the risk of invalid data transmission, select either to decode or ignore supplemental characters. NOTE

102

QuickScan® L

Page 109

UPC/EAN

Decode UPC/EAN/JAN Supplementals (continued)

Decode UPC/EAN/JAN Only With Supplementals

*Ignore Supplementals

Autodiscriminate UPC/EAN/JAN Supplementals

Enable 378/379 Supplemental Mode

Enable 978 Supplemental Mode

Enable Smart Supplemental Mode

Product Reference Guide

103