Page 81

Chapter 8 USB Interface This chapter covers the connection and setup of the scanner to a USB host. The scanner attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*North American Standard USB Keyboard

Feature/Option

Connecting a USB Interface Figure 12. USB Connection

USB Series A Connector

Interface cable

The scanner connects with USB capable hosts including: •

Desktop PCs and Notebooks

•

Apple™ iMac, G4, iBooks (North America only)

•

IBM SurePOS terminals

Product Reference Guide

75

Page 82

USB Interface

•

Sun, IBM, and other network computers that support more than one keyboard.

The following operating systems support the scanner through USB: •

Windows 98, 2000, ME, XP

•

MacOS 8.5 and above

•

IBM 4690 OS.

The scanner will also interface with other USB hosts which support USB Human Interface Devices (HID). For more information on USB technology, hosts, and peripheral devices, visit the website listed on the back cover of this manual. Interface cables vary depending on configuration. The connectors illustrated in Figure 12 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. NOTE

To set up the scanner: 1. Attach the modular connector of the USB interface cable to the cable interface port on the scanner (see Installing the Interface Cable on page 6). 2. Plug the series A connector in the USB host or hub, or plug the Plus Power connector in an available port of the IBM SurePOS terminal. 3. Select the USB device type by scanning the appropriate bar code from USB Device Type on page 77. 4. On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The scanner powers up during this installation. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter. 6. If problems occur with the system, see Table 3.

USB Parameter Defaults Table 16 lists the defaults for USB host parameters. If any option needs to be changed, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 77.

See Appendix B, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters. NOTE

76

QuickScan® L

Page 83

USB Host Parameters

Table 16. USB Defaults Parameter

Default

Page Number

USB Device Type

HID Keyboard Emulation

77

USB Country Keyboard Types (Country Codes)

North American

78

USB Keystroke Delay

No Delay

80

USB CAPS Lock Override

Disable

80

USB Ignore Unknown Characters

Send

81

Emulate Keypad

Disable

81

USB FN1 Substitution

Disable

82

Function Key Mapping

Disable

82

Simulated Caps Lock

Disable

83

Convert Case

No Case Conversion

83

USB Host Parameters

USB Host Parameters USB Device Type Select the desired USB device type.

When changing USB Device Types, the scanner automatically restarts. The scanner issues the standard startup beep sequences. NOTE

*USB Keyboard

USB OEM Table Top

Product Reference Guide

77

Page 84

USB Interface

USB Device Type, continued

USB OEM Handheld

For USB OPOS operation, use host type OEM USB and an appropriate driver supplied by Datalogic. NOTE

USB Country Keyboard Types (Country Codes) Scan the bar code corresponding to the keyboard type. This setting applies only to the USB HID Keyboard Emulation device.

When changing USB country keyboard types the scanner automatically resets. The scanner issues the standard startup beep sequences. NOTE

*North American Standard USB Keyboard

German Windows

French Windows

French Canadian Windows 95/98

78

QuickScan® L

Page 85

USB Host Parameters

USB Country Keyboard Types (Country Codes continued)

French Canadian Windows 2000/XP

Spanish Windows

Italian Windows

Swedish Windows

UK English Windows

Japanese Windows (ASCII)

Portuguese-Brazilian Windows

Product Reference Guide

79

Page 86

USB Interface

USB Keystroke Delay This parameter sets the delay, in milliseconds, between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.

*No Delay

Medium Delay (20 msec)

Long Delay (40 msec)

USB CAPS Lock Override This option applies only to the HID Keyboard Emulation device. When enabled, the case of the data is preserved regardless of the state of the caps lock key. This setting is always enabled for the “Japanese, Windows (ASCII)” keyboard type and cannot be disabled.

Override Caps Lock Key (Enable)

*Do Not Override Caps Lock Key (Disable)

80

QuickScan® L

Page 87

USB Host Parameters

USB Ignore Unknown Characters This option applies only to the HID Keyboard Emulation device and IBM device. Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then the scanner issues an error beep.

*Send Bar Codes with Unknown Characters

Do Not Send Bar Codes with Unknown Characters

Emulate Keypad When enabled, all characters are sent as ASCII sequences over the numeric keypad. For example ASCII A would be sent as “ALT make” 0 6 5 “ALT Break.”

*Disable Keypad Emulation

Enable Keypad Emulation

Product Reference Guide

81

Page 88

USB Interface

USB Keyboard FN 1 Substitution This option applies only to the USB HID Keyboard Emulation device. When enabled, this allows replacement of any FN 1 characters in an EAN 128 bar code with a Key Category and value chosen by the user (see FN1 Substitution Values on page 30 to set the Key Category and Key Value).

Enable FN1 Substitution

*Disable FN1 Substitution Function Key Mapping ASCII values under 32 are normally sent as a control-key sequences (see Table 17 on page 84). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.

*Disable Function Key Mapping

Enable Function Key Mapping

82

QuickScan® L

Page 89

USB Host Parameters

Simulated Caps Lock When enabled, the scanner will invert upper and lower case characters on the scanner bar code as if the Caps Lock state is enabled on the keyboard. This inversion is done regardless of the current state of the keyboard’s Caps Lock state.

*Disable Simulated Caps Lock

Enable Simulated Caps Lock

Convert Case When enabled, the scanner will convert all bar code data to the selected case.

*No Case Conversion

Convert All to Upper Case

Convert All to Lower Case

Product Reference Guide

83

Page 90

USB Interface

ASCII Character Set for USB Table 17. ASCII Character Set for USB ASCII Value

Full ASCII Code 39 Encode Character

Keystroke

1000

%U

CTRL 2

1001

$A

CTRL A

1002

$B

CTRL B

1003

$C

CTRL C

1004

$D

CTRL D

1005

$E

CTRL E

1006

$F

CTRL F

1007

$G

CTRL G

1008

$H

CTRL H/BACKSPACE1

1009

$I

CTRL I/HORIZONTAL TAB1

1010

$J

CTRL J

1011

$K

CTRL K

1012

$L

CTRL L

1013

$M

CTRL M/ENTER1

1014

$N

CTRL N

1015

$O

CTRL O

1016

$P

CTRL P

1017

$Q

CTRL Q

1018

$R

CTRL R

1019

$S

CTRL S

1020

$T

CTRL T

1021

$U

CTRL U

1022

$V

CTRL V

1023

$W

CTRL W

1024

$X

CTRL X

1025

$Y

CTRL Y

1

The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

84