Page 61

Chapter 7 Keyboard Wedge Interface This chapter describes how to set up a Keyboard Wedge interface with the scanner. With this interface, the scanner is connected between the keyboard and host computer, and translates bar code data into keystrokes. The host computer accepts the keystrokes as if they originated from the keyboard. This mode adds bar code reading functionality to a system designed for manual keyboard input. Keyboard keystrokes are simply passed through. Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

*North American

Feature/Option

Connecting a Keyboard Wedge Interface Figure 9. Keyboard Wedge Connection with Y-cable Male DIN Connector

Keyboard Connector

Product Reference Guide

Female DIN Connector

55

Page 62

Keyboard Wedge Interface

To connect the Keyboard Wedge interface Y-cable: Interface cables vary depending on configuration. The connectors illustrated in Figure 1 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. NOTE

1. Turn off the host and unplug the keyboard connector. 2. Attach the modular connector of the Y-cable to the cable interface port on the scanner. (See Installing the Interface Cable on page 6.) 3. Connect the round male DIN host connector of the Y-cable to the keyboard port on the host device. 4. Connect the round female DIN keyboard connector of the Y-cable to the keyboard connector. 5. If needed, attach the optional power supply to the connector in the middle of the Y-cable. 6. Ensure that all connections are secure. 7. Turn on the host system. 8. Select the Keyboard Wedge host type by scanning the appropriate bar code from Keyboard Wedge Host Parameters on page 57. 9. To modify any other parameter options, scan the appropriate bar codes in this chapter.

Keyboard Wedge Parameter Defaults See Appendix B, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters. NOTE

Table 9 lists the defaults for Keyboard Wedge host parameters. To change any option, scan the appropriate bar code(s) in the Keyboard Wedge Host Parameters section beginning on page 57. Table 9. Keyboard Wedge Defaults Parameter

Default

Page Number

Keyboard Wedge Host Parameters Keyboard Wedge Host Type

IBM PC/AT& IBM PC Compatibles1

57

Country Types (Country Codes)

North American

58

Ignore Unknown Characters

Send

59

Keystroke Delay

No Delay

60

Intra-Keystroke Delay

Disable

60

56

QuickScan® L

Page 63

Keyboard Wedge Host Parameters

Table 9. Keyboard Wedge Defaults (Continued) Parameter

Default

Page Number

Alternate Numeric Keypad Emulation

Disable

61

Caps Lock On

Disable

61

Caps Lock Override

Disable

62

Convert Wedge Data

No Convert

62

Function Key Mapping

Disable

63

FN1 Substitution

Disable

63

Send and Make Break

Send

63

1

User selection is required to configure this interface and this is the most common selection.

Keyboard Wedge Host Parameters Keyboard Wedge Host Types Select the Keyboard Wedge host by scanning one of the bar codes below.

User selection is required to configure this interface and this is the most common selection. NOTE

IBM PC/AT & IBM PC Compatibles1

IBM AT Notebook

NCR 7052

IBM PS/2 (Model 30)

Product Reference Guide

57

Page 64

Keyboard Wedge Interface

Keyboard Wedge Country Types (Country Codes) Scan the bar code corresponding to the keyboard type. If the keyboard type is not listed, see Alternate Numeric Keypad Emulation on page 61.

*North American

German Windows

French Windows

French Canadian Windows 95/98

French Canadian Windows XP/2000

Spanish Windows

Italian Windows

58

QuickScan® L

Page 65

Keyboard Wedge Host Parameters

Keyboard Wedge Country Types (continued)

Swedish Windows

UK English Windows

Japanese Windows

Portuguese-Brazilian Windows

Ignore Unknown Characters Unknown characters are characters the host does not recognize. When Send Bar Codes With Unknown Characters is selected, all bar code data is sent except for unknown characters, and no error beeps sound on the scanner. When Do Not Send Bar Codes With Unknown Characters is selected, bar code data is sent up to the first unknown character, then the scanner issues an error beep.

*Send Bar Codes with Unknown Characters

Do Not Send Bar Codes with Unknown Characters

Product Reference Guide

59

Page 66

Keyboard Wedge Interface

Keystroke Delay This is the delay in milliseconds between emulated keystrokes. Scan a bar code below to increase the delay when hosts require a slower transmission of data.

*No Delay

Medium Delay (20 msec)

Long Delay (40 msec)

Intra-Keystroke Delay When enabled, an additional delay is inserted between each emulated key depression and release. This sets the Keystroke Delay parameter to a minimum of 5 msec as well.

Enable Intra-Keystroke Delay

*Disable Intra-Keystroke Delay

60

QuickScan® L

Page 67

Keyboard Wedge Host Parameters

Alternate Numeric Keypad Emulation This allows emulation of most other country keyboard types not listed in Keyboard Wedge Country Types (Country Codes) on page 58 in a Microsoft® operating system environment.

Enable Alternate Numeric Keypad

*Disable Alternate Numeric Keypad Caps Lock On When enabled, the scanner emulates keystrokes as if the Caps Lock key is always pressed. Note that if both Caps Lock On and Caps Lock Override are enabled, Caps Lock Override takes precedence

Enable Caps Lock On

*Disable Caps Lock On

Product Reference Guide

61

Page 68

Keyboard Wedge Interface

Caps Lock Override When enabled, on AT or AT Notebook hosts, the keyboard ignores the state of the Caps Lock key. Therefore, an ‘A’ in the bar code is sent as an ‘A’ no matter what the state of the keyboard’s Caps Lock key.

If both Caps Lock On and Caps Lock Override are enabled, Caps Lock Override takes precedence. NOTE

Enable Caps Lock Override

*Disable Caps Lock Override Convert Wedge Data When enabled, the scanner will convert all bar code data to the selected case.

Convert to Upper Case

Convert to Lower Case

*No Convert

62

QuickScan® L

Page 69

Keyboard Wedge Host Parameters

Function Key Mapping ASCII values under 32 are normally sent as control key sequences (see Table 10 on page 64). When this parameter is enabled, the keys in bold are sent in place of the standard key mapping. Table entries that do not have a bold entry remain the same whether or not this parameter is enabled.

Enable Function Key Mapping

*Disable Function Key Mapping FN1 Substitution When enabled, the scanner replaces FN1 characters in an EAN128 bar code with a keystroke chosen by the user (see FN1 Substitution Values on page 30).

Enable FN1 Substitution

*Disable FN1 Substitution

Send Make and Break When enabled, the scan codes for releasing a key are not sent.

*Send Make and Break Scan Codes

Send Make Scan Code Only

Product Reference Guide

63

Page 70

Keyboard Wedge Interface

Keyboard Maps The following keyboard maps are provided for prefix/suffix keystroke parameters. To program the prefix/suffix values, see the bar codes on page 27 through page 29. Figure 10. IBM PC/AT 5001

5002

5003

5004

7008

7009

7014

7012

7003

7013 5005

5006

5007

5008

5009

5010

7004

7011

7002

Figure 11. IBM PS/2

ASCII Character Set for Keyboard Wedge

NOTE

Code 39 Full ASCII interprets the bar code special character ($ + % /) preceding a Code 39 character and assigns an ASCII character value to the pair. For example, when Code 39 Full ASCII is enabled and a +B is scanned, it is interpreted as b, %J as ?, and %V as @. Scanning ABC%I outputs the keystroke equivalent of ABC >.

Table 10. Keyboard Wedge ASCII Character Set ASCII Value

Full ASCII Code 39 Encode Character

Keystroke

1001

$A

CTRL A

1002

$B

CTRL B

1003

$C

CTRL C

1004

$D

CTRL D

1The keystroke in bold is sent only if the “Function Key Mapping” is enabled. Otherwise, the unbolded keystroke is sent.

64