Page 13

Chapter 3 Special Commands Pause Duration This parameter along with "Send Pause" on page 28 allows a pause to be inserted in the data transmission. Pauses are set by scanning a two-digit number (i.e., two barcodes), and are measured in 0.1 second intervals. For example, scanning barcodes “0” and “1” inserts a 0.1 second pause; “0” and “5” gives a 0.5 second delay. Numeric barcodes begin on page 86 in the chapter, Alphanumeric Keyboard. In case of an error, or to change the selection, scan Cancel on page 22.

Pause Duration

Begin New Rule Scan this barcode to start entering a new rule

Begin New Rule

Save Rule Scan this barcode to save the entered rule.

Save Rule

Advanced Data Formatting Guide

9

Page 14

Special Commands

Erase Use these barcodes to erase criteria, actions, or rules.

Erase Criteria And Start Again

Erase Actions And Start Again

Erase Previously Saved Rule

Erase All Rules

Quit Entering Rules Scan this barcode to quit entering rules.

Quit Entering Rules

10

QuickScan® L

Page 15

Disable Rule Set

Disable Rule Set Use these barcodes to disable rule sets.

Disable Rule Set 1

Disable Rule Set 2

Disable Rule Set 3

Disable Rule Set 4

Disable All Rule Sets

Advanced Data Formatting Guide

11

Page 16

Special Commands

NOTES

12

QuickScan® L