For the Datalogic MX4000

Page 1 read from a scan by OCR; it may hold reading errors

MX4000

Installation Manual

= >

DATALOGIC

Page 2 read from a scan by OCR; it may hold reading errors

MX4000

Installation Manual

= >

DATALOGIC

Page 3

MX4000 INSTALLATION MANUAL

Page 4

DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy

MX4000 Ed.: 12/01

ALL RIGHTS RESERVED Datalogic reserves the right to make modifications or improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material. Product names mentioned herein are for identification purposes only and may be trademarks and or registered trademarks of their respective companies. Datalogic S.p.A. 1998-2001

821000195 (Rev. E)

Page 5

CONTENTS

GENERAL VIEW .......................................................................................... v SAFETY PRECAUTIONS .............................................................................vi Power Supply................................................................................................vi FCC Compliance...........................................................................................vi 1 1.1

INTRODUCTION........................................................................................... 1 Available Models........................................................................................... 2

2 2.1 2.2 2.3 2.4 2.5 2.6 2.6.1 2.6.2 2.6.3 2.7 2.8 2.8.1 2.9

GENERAL FEATURES ................................................................................ 3 Display .......................................................................................................... 3 Keypad.......................................................................................................... 3 LEDs ............................................................................................................. 4 Removable Glands Panel ............................................................................. 5 On/Off Switch................................................................................................ 5 Host Communication Interfaces.................................................................... 5 Standard Serial Interface .............................................................................. 6 Profibus DP................................................................................................... 6 InterBus-S ..................................................................................................... 6 Auxiliary Interface ......................................................................................... 7 Peripheral Network Communications............................................................ 7 Multidrop Line ............................................................................................... 7 I/O ................................................................................................................. 7

3 3.1 3.2 3.2.1 3.2.2 3.2.3 3.3 3.3.1 3.4 3.4.1 3.4.2 3.5 3.6 3.6.1

INSTALLATION............................................................................................ 8 Package Contents ........................................................................................ 8 Guide to Installation ...................................................................................... 9 Standard Serial Interface .............................................................................. 9 Profibus DP Interface.................................................................................. 10 Interbus-S Interface .................................................................................... 10 Opening the Device .................................................................................... 11 Removing and Wiring the Glands Panels ................................................... 12 Mechanical Installation ............................................................................... 14 Overall Dimensions..................................................................................... 14 Mounting MX4000 ....................................................................................... 15 Connections to Power Supply..................................................................... 16 Connections to Host ................................................................................... 16 Standard Serial Interface - Main ................................................................. 16 Main Serial Interface Selection ................................................................... 17 Standard Serial Interface Grounding Rules ................................................ 18 Pinout.......................................................................................................... 19 RS232 Interface .......................................................................................... 20 iii

Page 6

3.8 3.9 3.9.1 3.9.2 3.10 3.10.1 3.10.2 3.10.3

RS485 Full-Duplex Interface....................................................................... 21 RS485 Half-Duplex Interface ...................................................................... 22 20 mA Current Loop Interface..................................................................... 23 Profibus Interface........................................................................................ 25 InterBus-S Interface .................................................................................... 27 Connections to Peripheral Devices............................................................. 29 Multidrop Line ............................................................................................. 29 Grounding the Multidrop Line...................................................................... 29 Connections to Auxiliary Interface .............................................................. 36 Connections to I/O ...................................................................................... 37 Inputs ...................................................................................................... 37 Outputs ...................................................................................................... 39 Typical Layouts ........................................................................................... 41 MX4000 Standard Serial Interface Layout .................................................. 41 MX4000 Profibus DP Layout....................................................................... 42 MX4000 InterBus-S Layout ......................................................................... 43

4

TECHNICAL FEATURES ........................................................................... 44

3.6.2 3.6.3 3.7 3.7.1

APPENDIX A DATA FORMATTING ........................................................ 46 Data Formatting Towards the Host ............................................................. 46 Time Info Disabled ...................................................................................... 46 Time Info Enabled....................................................................................... 47 Header-Terminator Selection...................................................................... 47 Data Formatting on the MX4000 Display .................................................... 48 iv

Page 7

GENERAL VIEW MX4000

4

3

2

1

7

6

5 Figure A

1 LDC Display

5 Glands panel

2 LEDs

6 On/Off switch

3 Keypad

7 Power supply connector

4 AUX port v

Page 8

SAFETY PRECAUTIONS POWER SUPPLY This unit is intended to be supplied by a UL Listed LPS or Class 2 power source with output rated 10-30 V dc, min. 0.6 A.

FCC COMPLIANCE This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

vi

Page 9

INTRODUCTION

1

1 INTRODUCTION The MX4000 is an industrial multiplexer which can be used to connect a series of data collection peripherals to a network. The network towards the host can be either a Standard serial interface or one of several different Fieldbus interfaces. Data collection between the MX4000 and the peripherals is accomplished on an RS485 Multidrop line. Standard Application Program A Standard Application Program is factory-loaded onto the MX4000. This program provides communication towards Host and peripheral devices connected to a Multidrop network. After configuration, a data collection session is started on the Multidrop line and collected data is sent to the Host. This data is non-associated data, that is, independent from one peripheral device to another. Each data string from each device on the Multidrop line is sent directly to the Host with the configured Data Formatting described in Appendix A. System configuration can be performed by the WINHOST interface utility program provided on diskette with the MX4000, or by using the Keyboard Mode through the keypad and the display, or by using the Host Mode programming procedure, sending ESC sequences via the serial interface. Programmability If your requirements are not met by the Standard Application Program, Custom Application Programs can be developed by your local Datalogic distributor.

1

Page 10

MX4000

1 Some of the main features of the MX4000 are given below: • serial or Profibus communication interfaces towards host

• connections to a PLC using Siemens protocols

•

RS485 multidrop interface for data collection from peripherals

• completely configurable from host or auxiliary computer

• optional Fieldbus communication interfaces towards host; DeviceNet™, Modbus Plus, etc.

• input and output signals available for custom application programs

For more details contact to your local Datalogic distributor. The MX4000 is contained in a rugged aluminum housing; the mechanical dimensions are 240 x 200 x 66 mm and it weighs about Kg 1.915.

1.1

AVAILABLE MODELS

The following models are available for MX4000:

MX4000 - XX00 Peripheral Device Network

Host Communication Interface

1 = RS485 Multidrop Network

0 = Standard serial interface: RS232, RS485 non-polled, RS485 polled, 20 mA C.L. 1 = Profibus DP interface 2 = Interbus S interface

2