Page 164
DRAGON™ D131/M131
5.4.5
Time Stamping Format
The Time Stamping parameter sets the format for hour and date information. It consists of 1 or 2 groups of numbers, each one made up of 6 decimal digits. For example, setting the Hour/Minutes/Seconds/Month/Day/Year format, the information 17:03:16 on June 12, 2002 will be formatted as 170316061202.
5.4.6
Time Stamping Delimiter
The Time Stamping Delimiter allows a character to be included to separate the Time Stamping field from the next field in the message. Any character can be included in the hexadecimal range from 00 to FE.
5.5
POWER SAVE
5.5.1
Sleep State
When using interfaces other than USB, this mode allows the μP in the reader to enter a “Sleep” state for minimum power consumption. For D-series readers, this command is only valid when hardware trigger type is selected. Before entering Sleep mode, the following are verified: • no commands coming from Host
• no data being transmitted to Host
•
Enter Sleep Timeout ended (see par. 5.5.2)
To exit Sleep mode press the trigger. For M131 series readers, sleep state is entered immediately after reading a code and is not configurable. To exit Sleep mode press the trigger. When using the USB interface, this mode allows the device to manage Selective Suspend conditions generated by the Host Operating System in which optimizing low power consumption (ex. Windows Stand-by). It is possible to exit the Suspend mode either from the Host (ex. moving the mouse during Stand-by) or through the barcode reader. The latter, called Remote Wakeup, makes the device wake up the Host restoring the communication. Remote Wakeup is possible by pressing the trigger.
156
Page 165
REFERENCES
5.5.2
Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.
5.6
READING PARAMETERS
5.6.1
Trigger Signal
This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected: • trigger active level: the reader goes ON when the trigger is pressed and goes OFF when it is released
• trigger active pulse: the reader goes ON at the first trigger press and goes OFF only at a second press
5.6.2
Trigger Click
When enabled, it activates a "click" sound upon each trigger pressure.
5.6.3
Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired period of time.
5.6.4
Reads per Cycle
In general, a reading cycle corresponds to the ON + OFF times of a device. The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times. • •
For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time. For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events: trigger release (for trigger active level) a second trigger press (for trigger active pulse) trigger-off timeout (see par. 5.6.3).
157
Page 166
DRAGON™ D131/M131
When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It is only possible to read another code when the next ON time occurs. In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For software trigger mode, the flash on period is immediately reset after each read and therefore extended. If another code is decoded before the reset flash on period expires, it is again reset and the effect is that the device remains ON, decoding codes until the flash on or timeout period expires. The Safety Time parameter should be used in this case to avoid unwanted multiple reading of the same code, see par. 5.6.5.
5.6.5
Safety Time
Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to be removed from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes. The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode, since these settings require voluntary action by the user.
5.7
DECODING PARAMETERS
CAUTION
5.7.1
These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.
Ink-Spread
The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink.
5.7.2
Overflow Control
The overflow control parameter can be disabled when decoding codes printed on small surfaces, which do not allow the use of an overflow space. This command does not affect code families 2/5, Code 128 and Code 93.
158
Page 167
REFERENCES
5.7.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.
5.8 5.8.1
ADVANCED FORMATTING Match Conditions
Selecting an Advanced Formatting and specifying a Match restriction (Code Type, Code Length, Predefined Characters) the code will be transmitted according to the order of the defined formats. For example, defining 2 formats where: • Format 1: Match Code type = Code128 • Format 2: Match Code length = 15 and Match with Predefined Characters “DATA” a Code128 “DATA:12345ABCDE” with code length 15 will be formatted following the Format 1. To send the same code with the Format 2 it is necessary to invert the format order as follows: • Format 1: Match Code length = 15 and Match with Predefined Characters “DATA” • Format 2: Match Code type = Code128
5.9 5.9.1
RADIO PARAMETERS (M131 SERIES ONLY) Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the M131 series reader and OM-30X0 cradle is considered failed. This parameter should be set taking into consideration the radio traffic (number of readers in the same area). If the RS232 interface is used with ACK/NACK enabled, this parameter should be at least equal to the RX Timeout parameter for low traffic environments. It should be increased if there are many readers in the same area. It can be set between 2 and 19 seconds.
159
Page 168
DRAGON™ D131/M131
5.9.2
Power-Off Timeout
If this command is enabled, after the desired timeout in hours, the Dragon™ batteries are disconnected and all power consumption ceases. To restore power, press the trigger once. The reader will now be ready to read codes. Power-off does not affect configuration parameters.
5.9.3
Transmission Mode
This parameter determines whether the reader receives responses or messages from the Host or not. In One-Way tx mode, neither Host nor cradle responds to the reader. In Two-Way tx mode, the reader must receive a response from either the cradle or the Host. The cradle responds (empty message) to the reader, only after good transmission to the Host, for the following conditions: ACK/NACK enabled, see par. 5.1.2; WEDGE or PEN interface. For these conditions, it is suggested to prolong the Radio Protocol Timeout, see par. 5.9.1. Enabling Two-Way tx mode temporarily disables FIFO buffering see par. 5.1.3.
160
Page 169
REFERENCES
With ACK/NACK disabled, the Host responds to the reader (through the cradle) with an answer message (message to reader display or command to reader), see par. 6.1 and the following figure. Transmission Mode = Two-Ways data data cable OM-30X0
DRAGON™ M Host answer message
5.9.4
Host
Host answer message
Beeper Control for Radio Response
For M131 series readers, the data entry good read tone normally results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether OM-30X0 has received the data. This can be changed according to the following selections: ♦ Normal: both good decode and good reception are signaled (two beeps). ♦ Only Good Decode: only the first beep indicating a good read is signaled. ♦ Only Good Reception: only the second beep indicating a good reception is signaled. ♦ Off: Neither good read nor good reception beeps are signaled. For all configurations, any transmission errors will always be signaled.
5.9.5
Single Store
When single store mode is enabled, if the Dragon™ M131 fails to transmit a code to the cradle, it enters a special operating mode that prevents the user from reading barcodes. When such operating mode is entered, the trigger no longer enables barcode reading but is used to retry transmission itself for the number of attempts selected in configuration. Once the transmission is successful the reader returns to the standard mode. If transmission is not successful after the number of configured attempts, the code is discarded. Single store may be useful if you often read codes at the limit of the coverage area and there is a chance that code transmission can fail. In such case single store allows you to move to a more favorable position or location (i.e. closer to the cradle) and retry transmission without the necessity of re-reading the code since it is already stored in the reader.
161
Page 170
DRAGON™ D131/M131
Conversely, if single store is disabled, and the user wants to retry transmission, the code must be read again, and therefore the attempt must be made from basically the same location. If the user gives up, he does not know if the transaction was successful. (Actually the transmission could have been successful but the cradle may have been unable to acknowledge the message). There are applications in which there is no risk of transmission failure. In such cases it may be better to disable single store so that the user perceives a more consistent behavior of the trigger in that it always corresponds to code reading.
5.9.6
Batch Mode
This Operating Mode allows storing read codes in the internal gun RAM memory. The stored codes are transmitted to the base station at a later time according to the type of batch mode selected. Batch mode can be enabled either manually (normal batch mode) or automatically. Normal batch mode temporarily suspends radio communication between gun and base station allowing codes to be stored in the gun on a FIFO basis. This can be useful for example, if codes must be read from a location where there is no radio network. Upon returning to the system working area, this mode requires reading the Start Normal Batch Transmission barcode to successively transmit the list of stored codes to the base station. The FIFO management assures that the first code read will be the first code to be transmitted to the base station. The Delete Batch Data barcode allows canceling all barcode data stored in the gun. Automatic batch mode allows codes to be stored in the gun on a FIFO basis whenever the gun is out of radio range. In this case radio communication is not suspended and transmission is attempted after each code read. If transmission cannot be successfully completed, then the code is added to the list. When the gun returns in range, transmission of the codes to the base station resumes automatically, according to the selected communication protocol, upon simply pressing and releasing the trigger or by successfully reading a new code. Each code is listed on the gun display together with its identifying position number and its total number of characters. The three keys under the display have the following function in batch mode: Key
Function
(left) Key
Scroll up in list
ENTER
(center) Key
Delete highlighted code
▼
(right) Key
Scroll down in list
▲
162
Page 171
REFERENCES
In batch mode, the selected Transmission Mode determines the behavior of the gun at the time the list of codes is transmitted. If One-way mode is enabled, the codes are transmitted one after the other without interruption. In Two-way mode, after transmitting each code, the gun waits for the Host answer message to be shown on the display. Therefore, in Two-way transmission mode and normal batch mode, the Start Normal Batch Transmission barcode must be read after each code to continue, whereas with automatic batch mode just pull and release the trigger after each code. The code which has a transmission pending is shown on the display in reverse video indicating that it cannot be deleted.
5.9.7
Find Me (Dragon M131 only)
If enabled, after a timeout of a few minutes in which Dragon™ M131 is not used, it enters stand-by mode and its green LED starts blinking in order to signal its location.
5.10 DISPLAY PARAMETERS (SOME M131 MODELS ONLY) 5.10.1
Display Mode
The user can control the gun display behavior according to the following selections: Normal mode: When a barcode is read with the gun: • • •
The code is sent to the Host. The gun display is not cleared. Therefore if any previous data was displayed on the gun screen it remains. There is no Local Echo to the gun display. Clear Display After Decode mode: When a barcode is read with the gun:
• • •
The code is sent to the Host. The gun display is cleared. Therefore if any previous data was displayed on the gun screen it is cancelled and the screen remains blank. There is no Local Echo of the code to the gun display. Local Echo mode: When a barcode is read with the gun:
• • • •
The code is sent to the Host. The gun display is cleared. The code is also sent to the gun display (Local Echo). The cursor is positioned after the last printed character on the gun display.
Host messages sent to the gun are always written to the gun display.