Page 148

DRAGON™ D131/M131

5

REFERENCES

5.1

RS232 PARAMETERS

5.1.1

Handshaking

Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder before transmitting a character. Transmission is possible only if the CTS line (controlled by the Host) is active. Signals at EIA levels

RTS

TX Transmitted data

Transmitted data

Host busy

CTS

RTS/CTS handshaking

Software handshaking: (XON/XOFF) During transmission, if the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received. Transmitted data

Transmitted data

TX

RX XOFF Host busy

XON Host ready

XON/XOFF handshaking

140

Page 149

REFERENCES

5.1.2

ACK/NACK Protocol

Dragon™ D131 Readers This parameter sets a transmission protocol in which the Host responds to the reader after every code transmitted. The Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. data cable

Dragon™ D

Host

ACK or NACK ACK/NACK enabled

If the reader does not receive an ACK or NACK, transmission is ended after the RX Timeout (see par. 5.1.4). When ACK/NACK protocol is enabled, FIFO must be disabled manually, see par. 5.1.3. Dragon™ M131 Readers The transmission protocol takes place between reader, cradle and Host. The reader passes its data (code read) to the cradle, which sends it to the Host. The management of responses (from Host or cradle) depends on the Transmission Mode parameter, see par. 5.9.3. In the following descriptions the completed transmission is indicated by the Beeper Control for Radio Response parameter with its default setting to Normal, see par. 5.9.4. When ACK/NACK is disabled (in One-Way tx mode), there is no control from cradle to Host transmission, the reader responds with the good reception tone. Transmission Mode = One-Way data data DRAGON™ M good RX beep

OM-30X0 cable

Host

ACK/NACK disabled

141

Page 150

DRAGON™ D131/M131 Transmission Mode = Two-Ways data data cable DRAGON™ M good RX beep

OM-30X0

NACK

Host data ACK

ACK/NACK enabled

When ACK/NACK is enabled (in Two-Way tx mode), the Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. Only after the ACK character is received by the OM-30X0 does the reader respond with the good reception tone. If the OM-30X0 does not receive an ACK or NACK, transmission is ended after the RX Timeout, see par. 5.1.4. See also Radio Protocol Timeout, par. 5.9.1. When ACK/NACK protocol is enabled, FIFO must be disabled manually, see par. 5.1.3.

5.1.3

FIFO

Dragon™ D131 Readers This parameter determines whether data (barcodes) are buffered on a First In First Out basis allowing faster data collection in certain cases for example when using slow baud rates and/or hardware handshaking. If the FIFO buffering is enabled, codes are collected and sent out on the serial line in the order of acquisition. About 800 characters can be collected (buffer full), after which the reader signals an error and discards any further codes until the transmission is restored. If the FIFO buffering is disabled, each code must be transmitted before another one can be read. Dragon™ M131 Readers If enabled, the OM-30X0 collects all messages sent by Dragon™ M131 and sends them in order of acquisition to the connected Host. If disabled, Dragon™ M131 blocks message transmission until the OM-30X0 has completed transmission towards the Host.

142

Page 151

REFERENCES

5.1.4

RX Timeout

When the RS232 interface is selected, the Host can be used to configure the device by sending it command strings (see Appendix A). This parameter can be used to automatically end data reception from the Host after the specified period of time. If no character is received from the Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer.

5.2 5.2.1

PEN PARAMETERS Minimum Output Pulse

This parameter sets the duration of the output pulse corresponding to the narrowest element in the barcode. In this way the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code read. The shortest pulse (200 μs) corresponds to a high-resolution code emulation and therefore a shorter transfer speed to the decoder (for decoders able to work on high resolution codes). Likewise, longer pulses correspond to low-resolution code emulation and therefore a longer transfer time to the decoder.

5.2.2

Conversion to Code 39 and Code 128

Dragon™ D131 Series Readers When using these readers it is possible to convert all codes to Code 39. By disabling this option the decoded codes will be transmitted in their original format; except for the following codes, which are ALWAYS converted into Code 39 format: MSI, Code 11, Code 16K, Code 49, RSS. Dragon™ M131 Series Readers When using these readers it is possible to choose between converting the decoded codes into either Code 39 format or Code 128 format. It is not possible to disable conversion.

143

Page 152

DRAGON™ D131/M131

5.2.3

Overflow

This parameter generates a white space before the first bar and after the last bar of the code. The selections are as follows: narrow medium wide

= space 10 times the minimum output pulse. = space 20 times the minimum output pulse. = space 30 times the minimum output pulse.

5.2.4

Output and Idle Levels

The following state diagrams describe the different output and idle level combinations for Pen emulation: idle bar

OUTPUT: Normal space

IDLE: Normal black white barcode output bar

OUTPUT: Normal idle IDLE: Inverted space black white barcode output space

OUTPUT: Inverted white idle bar

IDLE: Normal black barcode output OUTPUT: Inverted idle white space bar

IDLE: Inverted barcode output

Output and Idle Levels

144 black

Page 153

REFERENCES

5.2.5

Inter-Block Delay

For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The inter-block delay parameter allows setting a delay between each block sent to the Host.

5.3 5.3.1

NETWORK PARAMETERS Slave Address Range First/Last

These parameters define the valid addresses for the Slave cradles on the network. Valid values are in the range 0 to 1999. However, the maximum number of cradles in a single network is 16, (including the Master if present). All cradles in the system must have different addresses. To reduce system boot time, it is recommended to number the Slaves consecutively, while it is not necessary that the Master cradle address is contained in the range. The network addresses correspond to the radio addresses, see par. 4.7. At system power-up, the Master searches for and initializes all the Slaves found in the valid address range. During this phase the yellow LED on the Master cradle blinks. The time to complete the start up procedure varies depending on the complexity of the network but is typically between a few seconds to a few minutes. Start up cannot be interrupted. At the end of this procedure the system will be operative and can collect data from all devices.

CAUTION

5.3.2

All Slaves must be powered up either before or together with the Master. Slaves successively powered will not be recognized by the system even if their address is in the specified range.

Network Warning Message

The Master cradle can transmit warning messages to the Host regarding some network errors. /*Slave xxxx not responding*/: when the Master can no longer communicate with the specified Slave previously identified at start up. /*Frame out of sequence for terminal xxxx*/: if a gun is sending data packets out of sequence. This can happen if there are transmission problems on the network (either connection or communication), or if the gun has correctly transmitted data to a device not on the network (gun configuration error).

145

Page 154

DRAGON™ D131/M131

The message is sent in the following format: "Message" CR LF

5.3.3

Reception Warning Message

The Master cradle can transmit warning messages to the Host regarding wrong reception of data. Example: /*Two-Ways Out of Sequence!(.....)*/

This message is transmitted to the Host by the Master cradle when the Master cradle receives a closing string from the Host for a Two-way tx communication, but this was either not open or already closed, therefore the data will be lost. See par. 5.9.3.

5.3.4

Master Header/Terminator Selection

In addition to the standard header/terminator selection, the Master cradle can add its own header/terminator to the entire message sent to the Host. In the STAR-System™ network headers and terminators for all RF Devices are disabled by default. The Master header and terminator default values are as follows depending on the interface selection towards the Host: RS232:

no header, terminator CR-LF

WEDGE:

no header, terminator ENTER

See par. 5.4.1 and 5.4.2.

5.4

DATA FORMAT

For an overview of Message Formatting see Chapter 6.

5.4.1

Header/Terminator Selection

The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection:

146

RS232:

no header, terminator CR-LF

WEDGE:

no header, terminator ENTER

Page 155

REFERENCES

These default values are always restored through the reading of RS232 or WEDGE interface selection code, see chapter 2. For the WEDGE interface, the following extended keyboard values can also be configured: EXTENDED KEYBOARD TO HEX CONVERSION TABLE IBM AT IBM 3153 APPLE ADB

IBM XT

IBM 31xx, 32xx, 34xx, 37xx

Wyse Digital

HEX

KEY

KEY

KEY

KEY

83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Euro

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 ESC BACKSPACE HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Space

FIELD EXIT TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 ENTER RESET INSERT DELETE FIELD FIELD + ENTER (Paddle) PRINT

RETURN TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 UP DOWN LEFT RIGHT ESC CTRL (Right) Space

Space

For all devices using IBM AT (compatible) Wedge or USB-KBD interfaces, all values from 9C to FE send the relative simulated keypress when available or else the relative ALT-Mode sequence. See the Hex to Character Conversion Table in Appendix C. For all devices using other Wedge interfaces, all values from 9C to FE send the Space character.

147