Page 79

General Scanner Features

Good Read When to Indicate, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

GOOD READ = INDICATE AFTER TRANSMIT

GOOD READ = INDICATE AFTER CTS GOES INACTIVE, THEN ACTIVE (RS-232 ONLY)

Product Reference Guide

5-31

Page 80

Programming

EAS Active State Specifies the active state polarity of EAS (Electronic Article Surveillance); the inactive state is its opposite polarity. EAS output goes active during the good read of a bar code, allowing the EAS device to deactivate a tag on the product. To set the EAS Active State: 1. Scan the SWITCH bar code. 2. Scan bar code below representing the desired setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

EAS ACTIVE STATE = ACTIVE LOW

EAS ACTIVE STATE = ACTIVE HIGH

5-32

®

Magellan

2200VS and 2300HS

Page 81

General Scanner Features

EAS Timeout Specifies the amount of time that an EAS (Electronic Article Surveillance) signal is held in its active state for a good read. To set the EAS Timeout: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS TIMEOUT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired EAS Timeout duration. The selectable range is 0255, which is the timeout in 10-millisecond increments. Pad all single and double digit numbers with leading zeroes to yield a threedigit entry (000-255). Examples: 000 = EAS timeout disabled 001 = 10ms 005 = 50ms 040 = 400ms 250 = 2,500ms (2.5 seconds)

A setting of 0 (000) disables this feature. NOTE

4. The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned

SET EAS TIMEOUT

Product Reference Guide

5-33

Page 82

Programming

Aux Port Mode Selects the usage for the scanner’s optional auxilliary port. The choices listed below are mutually exclusive (only one option can be active at a time). •

Disabled, Port is inactive

•

External Handheld Input, Supports Datalogic® handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices.

Cable pinout information for the Aux Port is provided in Appendix B of this manual. A connected handheld scanner must be configured to transmit data as outlined in Appendix F. NOTE

•

PIR, (Productivity Index Reporting) allows the scanner to provide information to an external computer indicating how easy the label was to read.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

AUX PORT MODE = DISABLE

5-34

®

Magellan

2200VS and 2300HS

Page 83

General Scanner Features

Aux Port Mode, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

AUX PORT MODE = EXTERNAL HANDHELD INPUT

AUX PORT MODE = PIR

Product Reference Guide

5-35

Page 84

Programming

Productivity Index Reporting (PIR) When PIR is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

PIR = DISABLE

PIR = ENABLE

5-36

®

Magellan

2200VS and 2300HS

Page 85

Interface Related Features

Interface Related Features Interface Type Specifies the current scanner interface. Selections are: INTERFACE TYPE

PAGE NUMBER

RS-232 Standard

5-39

RS-232 Wincor-Nixdorf

5-40

RS-232 Single Cable

5-41

IBM USB

5-43

IBM Port 17

5-42

USB Keyboard

5-44

PC Keyboard Wedge

5-45

NOT USER-SELECTABLE Null Interface

Common factory configuration for new scanners

NOTE

A new scanner may have been shipped from the factory with a Null Interface (no interface type selected) to ensure system compatibility at installation. In this case, the correct Interface Type programming bar code must be scanned first before the scanner can be used with a POS system.

NOTE

If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Changing an interface type resets ALL other configuration items to the factory default for that interface type.)

Product Reference Guide

5-37

Page 86

Programming

Interface Type, continued To select the desired interface:

CAUTION

Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.

When an interface is selected, the scanner loads the factory configuration for that interface as the selection is made, erasing any and all custom configuration that may have previously been done. NOTE

1. Disconnect current interface cable(s) if currently connected. 2. Scan the SWITCH bar code 3. Scan the bar code representing the appropriate interface located on the following pages. You’ll need to cover any unused bar codes adjacent to and on any facing pages to ensure the scanner reads only the bar code you intend to scan. 4. Complete the programming sequence by scanning the SWITCH bar code.

NOTE

Once the correct interface has been set, it will be necessary to proceed to the appropriate pages in this manual that select parameters and options for that interface. For example, if RS-232 is selected, turn to the pages in this manual headed as features specific to the RS-232 interface.

5. Connect new interface cable(s).

5-38

®

Magellan

2200VS and 2300HS

Page 87

Interface Related Features

RS-232 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

CAUTION

Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.

INTERFACE TYPE = RS-232 STANDARD

Product Reference Guide

5-39

Page 88

Programming

RS-232 Wincor-Nixdorf Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.

CAUTION

Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.

INTERFACE TYPE = RS-232 WINCOR-NIXDORF

5-40

®

Magellan

2200VS and 2300HS