Page 331

Appendix A LED/Beeper Indications & Controls Figure A-1 shows the operator’s controls and indicators for both models.

The descriptions following identify the use or function of each component. Figure A-1. Scanner Controls and Indicators Speaker

Model 2200VS

Scan Window Indicator LED plus Volume/Tone Push Button

Upper Scan Window

Indicator LED

Volume/Tone Push Button Lower Scan Window

Top Cover

Model 2300HS

Volume/Tone Push Button The Volume/Tone Push Button also performs multiple functions depending upon the duration of time it is pressed:

NOTE

Volume changes made using the Volume/Tone Push Button are lost when the scanner is powered-down and are reset to the configured setting. If you wish to permanently change the volume, use the special programming labels in the Product Reference Guide.

Product Reference Guide

A-1

Page 332

Table A-1. Volume/Tone Push Button Functions PRESS DURATION

FUNCTION

Momentary (when scanner is asleep)

Wakes scanner from Sleep Mode

Alternatively, the scanner can be awakened by: - Moving an object through the scan zone. - Scanning with an attached auxiliary scanner.

Increments volume

Press the push button momentarily to increase speaker volume. When the loudest volume is reached, a repeated press of the push button cycles volume back to the lowest setting, then volume increases on subsequent press(es). Four volume levels are available.

Increments tone

Press the push button for approximately 2 seconds, then release. Each time this is done, the beeper will sound at one of three tones. Stop when the desired tone (high, medium or low) is sounded.

4 Seconds

Scanner Diagnostics Modea

This mode allows system support personnel to troubleshoot problems with the scanner and is used to determine if it can read bar codes. Press the button for eight seconds or cycle power to exit Scanner Diagnostics Mode and reset the scanner.

8 Seconds

Resets Scannerb

Only system support personnel should perform a reset.

Momentary (when scanner is awake)

Hold, then release when the beeper sounds

COMMENT a. By standard default, this function is normally disabled to prevent accidental activation by users. b. Users should not perform scanner resets except under the direction of trained systems support personnel.

Green LED Indicator The green LED indicates scanner status as shown in the table below. Table A-2. Green LED Indications LED INDICATION Scanner Activea (Normal Mode)

A-2

DURATION Scanner (Green) LED on steady and dim

COMMENT

The scanner is ready for operation. Scanning is immediately available.

®

Magellan

2200VS and 2300HS

Page 333

Table A-2. Green LED Indications LED INDICATION Good Read Indicationa Program Mode Indication Sleep Mode Indication

Host Disabled

Field Replaceable Unit (FRU) Warning (Error Mode)

FRU Indication

DURATION Scanner (Green) LED - bright flash Scanner (Green) LED - Continuous flashing

Scanner (Green) LED flashes slowly

Scanner (Green) LED 1-second off, 1/ 10-second on Audible low tone 1 second. LED flashes continuously.

Scanner (Green) LED flashes a coded sequence in concert with the speaker.

COMMENT

Indicates a bar code has been read and decoded. Indicates the scanner is in Label Programming Mode. Cycle power to exit Programming Mode. The scanner motor and/or laser have automatically switched off and the unit has entered Sleep Mode due to extended inactivity. Host has disabled scanning.

Serves notice that a fatal FRU failure has been detected. Call systems support for service.

Occurs ONLY upon Volume/Tone button push following a FRU warning. Enables service technicians to identify FRU failures.

a. Certain functions of the LED is selectable to be enabled or disabled. Your scanner may not be programmed to display all indications.