Page 169
PC Keyboard Wedge and USB Keyboard Interfaces
Quiet Interval, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
QUIET INTERVAL = 200 MILLISECONDS
.
QUIET INTERVAL = 500 MILLISECONDS
Product Reference Guide
5-121
Page 170
Programming
Quiet Interval, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
QUIET INTERVAL = ONE SECOND
5-122
®
Magellan
2200VS and 2300HS
Page 171
Symbology Programming
Symbology Programming
NOTE
If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Changing an interface type resets ALL other configuration items, including symbology programming, to the factory default for that interface type.)
UPC-A Enable Enables/disables the ability of the scanner to decode UPC-A labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A = DISABLE
UPC-A = ENABLE
Product Reference Guide
5-123
Page 172
Programming
UPC-A Number System Character Transmission Enables/disables transmission of a UPC-A number system character. This feature MUST be enabled for IBM interfaces for proper function. NOTE
This item is ignored when the advanced feature, Full Label Edit, is enabled.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A NUMBER SYSTEM CHARACTER TRANSMISSION = DISABLE
UPC-A NUMBER SYSTEM CHARACTER TRANSMISSION = ENABLE
5-124
®
Magellan
2200VS and 2300HS
Page 173
UPC-A Enable
UPC-A Check Character Transmission Enables/disables transmission of a UPC-A check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A CHECK CHARACTER TRANSMISSION = DISABLE
UPC-A CHECK CHARACTER TRANSMISSION = ENABLE
Product Reference Guide
5-125
Page 174
Programming
Expand UPC-A to EAN-13 Enables/disables expansion of UPC-A labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EXPAND UPC-A TO EAN/JAN-13 = DISABLE
EXPAND UPC-A TO EAN/JAN-13 = ENABLE
5-126
®
Magellan
2200VS and 2300HS
Page 175
UPC-A Enable
UPC/EAN AIM ID This feature enables/disables transmission of the UPC/EAN AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC/EAN AIM ID = DISABLE
UPC/EAN AIM ID = ENABLE
Product Reference Guide
5-127
Page 176
Programming
UPC-A Label ID This feature specifies a UPC-A label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.
SET UPC-A LABEL ID
5-128
®
Magellan
2200VS and 2300HS
Page 177
UPC-A Enable
UPC-A 2-Digit Supplemental Label ID This feature specifies a UPC-A 2-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 2-DIGIT SUPPLEMENTAL LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.
SET UPC-A 2-DIGIT SUPPLEMENTAL LABEL ID
Product Reference Guide
5-129
Page 178
Programming
UPC-A 5-Digit Supplemental Label ID This feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 5-DIGIT SUPPLEMENTAL LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.
SET UPC-A 5-DIGIT SUPPLEMENTAL LABEL ID
5-130
®
Magellan
2200VS and 2300HS