Page 99
Interface Related Features
Maximum Host-Transmitted Message Length Specifies the maximum number of data characters allowed in messages transmitted to the host. To set the Maximum Host-Transmitted Message Length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MAXIMUM HOST-TRANSMITTED MESSAGE LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum host-transmitted message length. The selectable range is 0-249 data characters. (Labels that are longer than this length are not read.) Pad all single and double digit numbers with leading zeroes to yield a three-digit entry (000-249).
If this configuration item is set to 0 (000), there is no general length limit imposed on data being transmitted to the host. NOTE
4. The scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned
SET MAXIMUM HOST-TRANSMITTED MESSAGE LENGTH
Product Reference Guide
5-51
Page 100
Programming
Number of Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted. When the feature, Good Read Beep Control, is enabled, the scanner will beep when the data is placed in a transmission buffer. When a DISABLE SCANNER command is received from the host, the scanner will continue to transmit all data that is buffered. To select the Number of Host Transmission Buffers: 1. Scan the SWITCH bar code. 2. Scan bar code below representing the desired setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
NUMBER OF HOST TRANSMISSION BUFFERS = 1
NUMBER OF HOST TRANSMISSION BUFFERS = 2
5-52
®
Magellan
2200VS and 2300HS
Page 101
Interface Related Features
Global Prefix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the prefix that is added to beginning of label transmission. To specify the Global Prefix Character(s): 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GLOBAL PREFIX below. You’ll need to cover any unused bar codes to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the hex designation for the desired character(s). A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. Up to 20 hex pairs can be designated.
To specify “no Global Prefix,” scan 00. NOTE
4. If designating the full 20 hex pairs, the scanner will automatically exit Programming Mode when the appropriate amount of digits have been scanned. If designating less than 20 hex pairs, you can end the programming sequence early by scanning the TERMINATE SEQUENCE bar code. 5. Complete the programming sequence by scanning the SWITCH bar code.
Product Reference Guide
5-53
Page 102
Programming
Global Prefix, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
SET GLOBAL PREFIX
TERMINATE SEQUENCE
5-54
®
Magellan
2200VS and 2300HS
Page 103
Interface Related Features
Global Suffix This feature applies to RS-232 interfaces (Standard, Wincor-Nixdorf, and Single Cable). It specifies the suffix that is added to end of a label transmission. Three standard options are available below. Contact your dealer for other alternate settings for this feature. •
No Global Suffix
•
CR, Carriage Return
•
CR LF, Carriage Return, Line Feed
To set the Global Suffix: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. 3. Complete the programming sequence by scanning the SWITCH bar code.
GLOBAL SUFFIX = NO GLOBAL SUFFIX
Product Reference Guide
5-55
Page 104
Programming
Global Suffix, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GLOBAL SUFFIX = CR
GLOBAL SUFFIX = CR LF
5-56
®
Magellan
2200VS and 2300HS
Page 105
IBM Features
IBM Features IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B; Code 128, Code 93 and Codabar for IBM-USB.
When enabled, this feature has no effect on IBM Port 17. NOTE
To enable/disable the IBM Transmit Labels in Code 39 Format feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
IBM TRANSMIT LABELS IN CODE 39 FORMAT = DISABLE
IBM TRANSMIT LABELS IN CODE 39 FORMAT = ENABLE
Product Reference Guide
5-57
Page 106
Programming
IBM USB Scanner Device Type The IBM-USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB POS, you may need to change this setting to enable all scanners to communicate. Options are: •
Fixed Position Scanner
•
Handheld Scanner
To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
IBM USB SCANNER DEVICE TYPE = FIXED POSITION SCANNER
IBM USB SCANNER DEVICE TYPE = HANDHELD SCANNER
5-58
®
Magellan
2200VS and 2300HS
Page 107
RS-232 Features
RS-232 Features RS-232 Baud Rate This feature selects the baud rate required for sending and receiving data. Single cable interfaces are limited to Baud Rate selections up to 19200. They cannot communicate at Baud Rates of 38400 and up. NOTE
To specify the RS-232 Baud Rate: 1. Scan the SWITCH bar code. 2. Scan the desired baud rate from the bar codes below and on the immediately following pages. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 BAUD RATE = 1200
RS-232 BAUD RATE = 2400
Product Reference Guide
5-59
Page 108
Programming
RS-232 Baud Rate, continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 BAUD RATE = 4800
RS-232 BAUD RATE = 9600
5-60
®
Magellan
2200VS and 2300HS