QuickScan Mobile Reference Manual: 2 INSTALLATION
Pages 9 to 14 of 176, from QuickScan Mobile Reference Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic M2130
Page 9
INSTALLATION
2 INSTALLATION USING YOUR QUICKSCAN® MOBILE READING SYSTEM
2.1
Follow the procedure below to start using your QuickScan® Mobile reading system: 1. Connect a QuickScan® Mobile cradle to the Host. 2. Insert the QuickScan® Mobile reader into the cradle to start the battery charging. A full charge of the Lithium battery takes 3.5 – 6 hours.
To achieve the best battery life, it is recommended to perform a full battery charge before using the reader in hand-held mode. NOTE In hands-free use, you can immediately start using the reader, since it is powered by the cradle. Configure the QuickScan® Mobile reader. Configure the QuickScan® Mobile cradle.
3. 4.
2.2
CHANGING THE BATTERIES
To change the battery of your reader, you must: 1. Unscrew the battery cover screw (Figure 1). 2. Unplug the white connector and remove the old battery (Figure 2). 3. Insert the new battery and plug in the white connector.
When inserting the new battery into the handle pay attention to position the battery and the connector just as shown in Figure 3. NOTE
Figure 1
Figure 2
Figure 3
3
Page 10
®
QUICKSCAN MOBILE
4.
Insert the cover in the handle and screw it back into place.
Figure 4
WARNING
4
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
Page 11
INSTALLATION
2.3
SYSTEM CONNECTIONS
Connections should always be made with power OFF! CAUTION
You can connect the QuickScan® Mobile cradle to the Host through the dedicated connector, using the cable corresponding to the desired interface type. 1.
Connect the appropriate interface cable to the cradle by simply plugging it into the Host connector on the base of the cradle.
Interface Cable
QuickScan® Mobile Cradle - Bottom View
To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the connector on the base of the cradle. Push down on the clip while unplugging the cable. Refer to the following figure:
Disconnecting the Cable
5
Page 12
®
QUICKSCAN MOBILE
2.4
RS-232 CONNECTION
2.5
USB
2.6
IBM USB POS
CAB-413
2.7
WEDGE CONNECTION (only for Quickscan M2 Type:130)
CAB-391 or CAB-321 + CAB-431
6
Page 13
INSTALLATION
CAB-431 POWER SUPPLY ADAPTER
2.8
IBM PORT9B / IBM PORT 5B (only for Quickscan M2 Type:110)
CAB-445 CAB-446
2.9
PEN EMULATION CONNECTION
CAB-431 POWER SUPPLY ADAPTER
7