Page 160

®

QUICKSCAN MOBILE

WEDGE DESCRIPTION Keyboard nationality

Caps Lock Caps Lock Auto-Recognition (IBM AT compatible only) Num Lock Delays Control Character Emulation

Belgian English French German Italian Spanish Swedish USA Japanese (IBM AT compatible only) caps Lock ON caps Lock OFF disable enable Toggle Num Lock Num Lock Unchanged Inter-Character (ms) Inter-Code (s) CTRL + Shift + Key CTRL + Key

STRING FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FE1 FE0 FP0 FP1 FL1 FL0 CK00 - CK99 FG00 - FG99 FO0 FO1

PEN DESCRIPTION Operating mode interpret (does not require $+ or $-) transparent (does not require $+ or $-) Minimum output pulse 200μs 400μs 600μs 800μs 1 ms 1.2 ms Conversion to Code 39 and enable conversion to Code 39 Code 128 enable conversion to Code 128 (M series only) Output level normal inverted Idle level normal inverted Overflow narrow overflow medium overflow wide overflow Inter-Block delay (100 ms)

154

STRING $] $[ DG0 DG1 DG2 DG3 DG4 DG5 DA1 DA2 DD0 DD1 DE0 DE1 DH0 DH1 DH2 CK00-CK99

Page 161

HOST CONFIGURATION STRINGS

DATA FORMAT

NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Identifier disable Datalogic standard AIM standard Custom

Custom Code Identifier Headers

Terminators

Special Keys no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters five characters six characters seven characters eight characters special key 1 special key 2 special key 3 special key 4 special key 5

STRING EB0 EB1 EB2 EB3 EHabc EA00 EA01x EA02xx EA03xxx EA04xxxx EA05xxxxx EA06xxxxxx EA07xxxxxxx EA08xxxxxxxx EA10 EA11x EA12xx EA13xxx EA14xxxx EA15xxxxx EA16xxxxxx EA17xxxxxxx EA18xxxxxxxx 9C 9D 9E 9F A0 a = ASCII character. b, c, x = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 52. b = Hex value of the first Custom Code Identifier character from 00 to FD; FF = disable Code Identifier c = Hex value of the second Custom Code Identifier character from 00 to FD; FF = disable second character of Custom Code Identifier x = Hex value from 00 to FE

155

Page 162

®

QUICKSCAN MOBILE

DATA FORMAT (continued)

NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Length Tx

Field Adjustment

Field Adjustment Character Character Replacement

Address Stamping Address Delimiter not transmitted transmitted in variable-digit format transmitted in fixed 4-digit format disable right addition left addition right deletion left deletion disable character replacement first character replacement second character replacement third character replacement disable reader address stamping enable reader address stamping disable reader address delimiter enable reader address delimiter and select character

STRING EE0 EE1 EE2 EF0 EFa0d EFa1d EFa2d EFa3d EGe EO0 EO1afg EO2afg EO3afg RU0 RU1 RV0 RV1h a = ASCII character. d = a number from the Hex/Numeric Table e, f, g, h = HEX values representing an ASCII character a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 52. d = a number in the range 01-32 from the Hex/Numeric Table e = Hex value from 00 to FE f = Hex value of the character to be replaced from 00 to FE g = Hex value of the new character to insert from 00 to FE FF = replace with no new character (remove character)

h = a HEX value in the range from 00 - FE representing the ASCII character.

156

Page 163

HOST CONFIGURATION STRINGS

READING PARAMETERS DESCRIPTION Hand-Held Operation

Stand Operation

Hardware Trigger Mode Trigger-off Timeout (s) FLASH ON (100 ms) FLASH OFF (100 ms) Reads per Cycle Safety Time (100 ms) Beeper Intensity

Beeper Tone

Beeper Type Beeper Length Stand Recognition Beep software trigger hardware trigger automatic always on hardware trigger ready software trigger hardware trigger automatic always on trigger active level trigger active pulse one read multiple reads very low intensity low intensity medium intensity high intensity tone 1 tone 2 tone 3 tone 4 monotone bitonal long short disable enable

STRING BK0 BK1 BK2 BK3 BK4 BU1 BU3 BU0 BU2 BA0 BA1 BD00 - BD99 BB001 - BB099 BB101 - BB199 BC0 BC1 BE00 - BE99 BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 BJ0 BJ1 BI0 BI1 Ba0 Ba1

157

Page 164

®

QUICKSCAN MOBILE

DECODING PARAMETERS DESCRIPTION Ink-spread Overflow control Interdigit control Puzzle Solver

TM

Decoding Safety disable enable disable enable disable enable disable enable one read two reads three reads four reads

CODE SELECTION DESCRIPTION DISABLE ALL FAMILY CODES EAN/UPC disable EAN/UPC family EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON EAN 8/EAN 13 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 UPC A/UPC E without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 EAN/UPC with and without Add On no Autodiscrimination EAN/UPC Autodiscrimination Add On by Prefix Select Prefixes cancel all selections 378/379 434/439 414/419 977 978 979 EAN 8 check digit transmission Disable Enable EAN 13 check digit transmission disable enable UPC A check digit transmission disable enable

158

STRING AX0 AX1 AW1 AW0 AV0 AV1 AU0 AU1 ED0 ED1 ED2 ED3

STRING AZ0 AA0 AA1 AA5 AA3 AAK AAL AA6 AA4 AAM AAN AA7 AA8Ad0 AA8Ad1 ET0 ET1378ET2379 ET3434ET4439 ET5414ET6419 ET7977 ET8978 ET9979 AAG0 AAG1 AAH0 AAH1 AAI0 AAI1

Page 165

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION EAN/UPC UPC E check digit transmission disable enable conversions UPC E to UPC A UPC E to EAN 13 UPC A to EAN 13 EAN 8 to EAN 13 ISBN Conversion codes enable ISBN enable ISSN enable ISBN and ISSN disable ISBN and ISSN Code 39 disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP 39 Code 32 code length 2/5 disable Code 2/5 family Interleaved 2/5 no check digit control check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control check digit control and transmission check digit control without transmission CIP/HR

STRING AAJ0 AAJ1 AAA AAB AAC AAD AP1 AP2 AP3 AP0 AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5 xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters: Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

159

Page 166

®

QUICKSCAN MOBILE

CODE SELECTION (continued) DESCRIPTION Codabar disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC Codabar no start/stop character equality control but transmission Codabar ABC forced concatenation code length start/stop character case in transmission lower case upper case Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit Transmit GS before disable Code enable ISBT 128 enable ISBT 128 code length Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit MSI disable the family no check MOD10 no tx MOD10 with tx MOD11-MOD10 no tx MOD11-MOD10 with tx MOD10-MOD10 no tx MOD10-MOD10 with tx xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters: EXAMPLES: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

160

STRING AD0 AD111 AD112 AD121 AD122 AD212 AD232 AD*xxxx ADA0 ADA1 AI0 AI11 AI21 EQ0 EQ1 AI31 AILxxxx AK0 AK1 AE0 AE1 AE2 AE3 AE4 AE5 AE6 AE7

Page 167

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION

STRING

Plessey disable the family Standard no check Standard check - with tx Standard check - no tx Anker no check Anker check - with tx Anker check - no tx

AF0 AF11 AF12 AF13 AF21 AF22 AF23

Telepen disable the family Numeric no check Numeric check - with tx Numeric check - no tx Alpha no check Alpha check - with tx Alpha check - no tx disable the family no check Type 1 check Type 2 check disable the family no check Type C with tx Type C no tx Type K with tx Type K no tx Type C and K with tx Type C and K no tx disable enable disable enable disable the family disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked

AL0 AL11 AL12 AL13 AL21 AL22 AL23 AH0 AH1 AH2 AH3 AG0 AG1 AG21 AG22 AG31 AG32 AG41 AG42 AJ0 AJ1 AM0 AM1 AQ0 AQ10 AQ11 AQ20 AQ21 AQ30 AQ31

Delta IBM

Code 11

Code 16K Code 49 GS1 DataBar™

161

Page 168

®

QUICKSCAN MOBILE

RADIO PARAMETERS DESCRIPTION Radio Protocol Timeout enable (seconds) Power-Off Timeout Beeper Control For Radio Response normal only good decode only good reception off Single Store disable one attempt two attempts three attempts four attempts five attempts six attempts seven attempts eight attempts nine attempts Batch Mode disable normal automatic

162

STRING RH02-RH19 RP00-RP99 BF0 BF1 BF2 BF3 RO0 RO1 RO2 RO3 RO4 RO5 RO6 RO7 RO8 RO9 BZ0 BZ1 BZ2