Page 144
®
QUICKSCAN MOBILE
4.4.5
Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.
4.4.6
Standby
If this command is enabled, part of the CCD circuitry shuts down (Standby), in order to optimize low power consumption when not reading. When the trigger is pressed this circuitry powers up. This mode causes a minor delay of about 100 ms before the reader is ready. Standby is always enabled and is not configurable. To exit Standby press the trigger.
4.5
READING PARAMETERS
4.5.1
Hardware Trigger Mode
This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected: • trigger active level: the reader goes ON when the trigger is pressed and goes OFF when it is released
• trigger active pulse: the reader goes ON at the first trigger press and goes OFF only at a second press
4.5.2
Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired period of time.
4.5.3
Reads per Cycle
In general, a reading cycle corresponds to the ON + OFF times of a device. The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times. •
138
For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time.
Page 145
REFERENCES
•
For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events: trigger release (for trigger active level) a second trigger press (for trigger active pulse) trigger-off timeout (see par. 4.5.2).
When one read per cycle is selected, the device decodes only one code during the ON period and immediately turns the reader OFF. It is only possible to read another code when the next ON time occurs. In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For software trigger mode, the flash on period is immediately reset after each read and therefore extended. If another code is decoded before the reset flash on period expires, it is again reset and the effect is that the device remains ON, decoding codes until the flash on or timeout period expires. The Safety Time parameter should be used in this case to avoid unwanted multiple reading of the same code, see par. 4.5.4.
4.5.4
Safety Time
Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to be removed from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes. The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode, since these settings require voluntary action by the user.
4.6
DECODING PARAMETERS
CAUTION
4.6.1
These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.
Ink-Spread
The ink-spread parameter allows the decoding of codes, which are not perfectly printed because the page texture tends to absorb the ink.
139
Page 146
®
QUICKSCAN MOBILE
4.6.2
Overflow Control
The overflow control parameter can be disabled when decoding codes printed on small surfaces, which do not allow the use of an overflow space. This command does not affect code families 2/5, Code 128 and Code 93.
4.6.3
Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.
4.7 4.7.1
RADIO PARAMETERS Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the reader and the cradle is considered failed. This parameter should be set taking into consideration the radio traffic (number of readers in the same area). If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at least equal to the RX Timeout parameter for low traffic environments. It should be increased if there are many readers in the same area. It can be set between 2 and 19 seconds.
4.7.2
Power-Off Timeout
If this command is enabled, after the desired timeout in hours, the batteries are disconnected and all power consumption ceases. To restore power, press the trigger once. The reader will now be ready to read codes. Power-off does not affect configuration parameters.
4.7.3
Beeper Control for Radio Response
The data entry good read tone normally results in two beeps; the first indicates that the reader has decoded the code; the second indicates whether cradle has received the data. This can be changed according to the following selections: ♦ Normal: both good decode and good reception are signaled (two beeps).
140
Page 147
REFERENCES
♦ Only Good Decode: only the first beep indicating a good read is signaled. ♦ Only Good Reception: only the second beep indicating a good reception is signaled. ♦ Off: Neither good read nor good reception beeps are signaled. For all configurations, any transmission errors will always be signaled.
4.7.4
Single Store
When single store mode is enabled, if the QuickScan® Mobile fails to transmit a code to the cradle, it enters a special operating mode that prevents the user from reading barcodes. When such operating mode is entered, the trigger no longer enables barcode reading but is used to retry transmission itself for the number of attempts selected in configuration. Once the transmission is successful the reader returns to the standard mode. If transmission is not successful after the number of configured attempts, the code is discarded. Single store may be useful if you often read codes at the limit of the coverage area and there is a chance that code transmission can fail. In such case single store allows you to move to a more favorable position or location (i.e. closer to the cradle) and retry transmission without the necessity of re-reading the code since it is already stored in the reader. Conversely, if single store is disabled, and the user wants to retry transmission, the code must be read again, and therefore the attempt must be made from basically the same location. If the user gives up, he does not know if the transaction was successful. (Actually the transmission could have been successful but the cradle may have been unable to acknowledge the message). There are applications in which there is no risk of transmission failure. In such cases it may be better to disable single store so that the user perceives a more consistent behavior of the trigger in that it always corresponds to code reading.
4.7.5
Batch Mode
This Operating Mode allows storing read codes in the internal reader RAM memory. The stored codes are transmitted to the base station at a later time according to the type of batch mode selected. Batch mode can be enabled either manually (normal batch mode) or automatically. Normal batch mode temporarily suspends radio communication between reader and base station allowing codes to be stored in the reader on a FIFO basis. This can be useful for example, if codes must be read from a location where there is no radio network. Upon returning to the system working area, this mode requires reading the Start Normal Batch Transmission barcode to successively transmit the list of
141
Page 148
®
QUICKSCAN MOBILE stored codes to the base station. The FIFO management assures that the first code read will be the first code to be transmitted to the base station. The Delete Batch Data barcode allows canceling all barcode data stored in the reader. Automatic batch mode allows codes to be stored in the reader on a FIFO basis whenever the reader is out of radio range. In this case radio communication is not suspended and transmission is attempted after each code read. If transmission cannot be successfully completed, then the code is added to the list. When the reader returns in range, transmission of the codes to the base station resumes automatically, according to the selected communication protocol, upon simply pressing and releasing the trigger or by successfully reading a new code.
142
Page 149
REFERENCES
4.8
CONFIGURATION EDITING COMMANDS
The following commands carry out their specific function and then exit the configuration environment. Command
Description
Ì$+$*oÎ
Restore the reader default configuration (see the relative Quick Reference Manual for default settings)
Ì$+$!KÎ
Transmit the reader Software release
Ì$+$&_Î
Transmit the reader configuration in ASCII format. This command is not effective with Pen emulation interface or with the reader model.
Ì$+RX0$-qÎ
Restore the cradle default configuration (see the relative Quick Reference Manual for default settings)
Ì$+RX1$-vÎ
Transmit the cradle Software release.
Ì$+RX2$-{Î
Transmit the cradle configuration in ASCII format. This command is not effective with Pen emulation interface.
143
Page 150
®
QUICKSCAN MOBILE
4.9
DEFAULT PARAMETERS FOR POS TERMINALS
The default values of the RS-232 and Data Format parameters for POS terminals are listed in the following table: NIXDORF Mode A
FUJITSU
ICL Mode
9600 Odd 8 1 Hardware (RTS/CTS) Disabled Disabled Disabled 9.9 sec Disabled
9600 None 8 1 None Disabled Enabled Disabled 2 sec Disabled
9600 Even 8 1 RTS always ON Disabled Enabled Disabled 9.9 sec Disabled
Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled
Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled
Custom No Header CR Disabled Not Transmitted Disabled Disabled Disabled
RS-232 Group Baud Rate Parity Data Bits Stop Bits Handshaking ACK/NACK Protocol FIFO Inter-Character Delay RX Timeout Serial Trigger Lock Data Format Group Code Identifier Header Terminator Field Adjustment Code Length TX Character Replacement Address Stamping Address Delimiter
The table below lists all the Code Identifiers available for the POS terminals: CODE UPC-A UPC-E EAN-8 EAN-13 Code 39 Codabar Code 128 Interleaved 2 of 5 Code 93 Industrial 2 of 5 UCC/EAN 128 MSI/Plessey RSS Other
144
NIXDORF Mode A A0 C0 B A M N K I L H P O E None
FUJITSU A E FF F None None None None None None None None None None
ICL Mode A E FF F C [code length] N [code length] L [code length] I [code length] None H [code length] L [code length] None None None