QuickScan Mobile Reference Manual: 3 CONFIGURATION, pages 95 to 104
Pages 95 to 104 of 176, from QuickScan Mobile Reference Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic M2130
Page 95
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
CODE SELECTION
CODABAR FAMILY
‹ disable the family
ÌAD0SÎ c Read the desired equality control code d
Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION
Standard Codabar
ÌAD113Î no start/stop character equality control no transmission
Ì12Î Standard Codabar
ÌAD127Î start/stop character equality control transmission
Ì23Î The Codabar ABC code below uses a fixed start/stop character transmission selection.
Codabar ABC
ÌAD212)Î no start/stop character equality control but transmission.
89
Page 96
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
CODE SELECTION Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation
ÌAD2321Î non start/stop character equality control but transmission
CODE LENGTH (optional) The code length selection is valid for the entire Codabar family set code length
Read the code + 4 numbers for the code length where: First 2 digits = minimum code length. Second 2 digits = maximum code length.
ÌAD*AÎ
The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.
START/STOP CHARACTER CASE IN TRANSMISSION
The start/stop character case selections below are valid for the entire Codabar family:
transmit start/stop characters in lower case
ÌADA0_Î transmit start/stop characters in upper case
ÌADA1cÎ
90
Page 97
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
MSI ‹ disable the family
ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control
ÌAE1XÎ MOD10 check digit control no check digit transmission
ÌAE2[Î MOD10 check digit control check digit transmission
ÌAE3^Î MOD11 - MOD10 check digit control no check digit transmission
ÌAE4aÎ MOD11 - MOD10 check digit control check digit transmission
ÌAE5dÎ MOD10 - MOD10 check digit control no check digit transmission
ÌAE6gÎ MOD10 - MOD10 check digit control check digit transmission
ÌAE7jÎ 91
Page 98
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
PLESSEY ‹ disable the family
ÌAF0WÎ Enable the code by selecting one of the check digit selections.
Standard Plessey no check digit control
ÌAF117Î check digit control check digit transmitted
ÌAF12;Î check digit control check digit not transmitted
ÌAF13?Î Anker Plessey no check digit control
ÌAF21:Î check digit control check digit transmitted
ÌAF22>Î check digit control check digit not transmitted
ÌAF23BÎ 92
Page 99
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
TELEPEN ‹ disable the family
ÌAL0cÎ Enable the code by selecting one of the check digit selections.
Numeric Telepen no check digit control
ÌAL11CÎ check digit control check digit transmitted
ÌAL12GÎ check digit control check digit not transmitted
ÌAL13KÎ Alphanumeric Telepen no check digit control
ÌAL21FÎ check digit control check digit transmitted
ÌAL22JÎ check digit control check digit not transmitted
ÌAL23NÎ 93
Page 100
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
DELTA IBM ‹ disable the family
ÌAH0[Î Enable the code by selecting one of the check digit selections.
no check digit control
ÌAH1^Î
Type 1 check digit control
ÌAH2aÎ
Type 2 check digit control
ÌAH3dÎ
94
Ì$-?Î
Page 101
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
CODE 11 ‹ disable the family
ÌAG0YÎ Enable the code by selecting one of the check digit selections. no check digit control
ÌAG1\Î Type C check digit control check digit transmitted
ÌAG21<Î Type C check digit control check digit not transmitted
ÌAG22@Î Type K check digit control check digit transmitted
ÌAG31?Î Type K check digit control check digit not transmitted
ÌAG32CÎ Type C and Type K check digit control check digits transmitted
ÌAG41BÎ Type C and Type K check digit control check digits not transmitted
ÌAG42FÎ
95
Page 102
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
CODE 16K
‹ disable the code
ÌAJ0_Î
Code 16K
ÌAJ1bÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
CODE 49
‹ disable the code
ÌAM0eÎ
Code 49
ÌAM1hÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
96
Page 103
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
GS1 DATABAR™ ‹ disable the family
ÌAQ0mÎ DISABLE CODE ENABLE CODE disable RSS Expanded Linear and Stacked
ÌAQ10IÎ enable RSS Expanded Linear and Stacked
ÌAQ11MÎ disable RSS Limited
ÌAQ20LÎ enable RSS Limited
ÌAQ21PÎ disable RSS 14 Linear and Stacked
ÌAQ30OÎ enable RSS 14 Linear and Stacked
ÌAQ31SÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
97
Page 104
ADVANCED FORMATTING NOT FOR PEN INTERFACES
~ ~
CONCATENATION ADVANCED FORMATTING
~ ~
Please follow the setup procedure carefully for these parameters. NOTE
The Advanced Formatting parameters may not be compatible with the IBM USB POS interface selection. NOTE
1. 2.
Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given. = Read the code and follow the procedure given ‹
3. 98
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of page.