Page 95

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

CODE SELECTION

CODABAR FAMILY

‹ disable the family

ÌAD0SÎ c Read the desired equality control code d

Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION

Standard Codabar

ÌAD113Î no start/stop character equality control no transmission

Ì12Î Standard Codabar

ÌAD127Î start/stop character equality control transmission

Ì23Î The Codabar ABC code below uses a fixed start/stop character transmission selection.

Codabar ABC

ÌAD212)Î no start/stop character equality control but transmission.

89

Page 96

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

CODE SELECTION Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation

ÌAD2321Î non start/stop character equality control but transmission

CODE LENGTH (optional) The code length selection is valid for the entire Codabar family set code length

Read the code + 4 numbers for the code length where: First 2 digits = minimum code length. Second 2 digits = maximum code length.

ÌAD*AÎ

The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.

START/STOP CHARACTER CASE IN TRANSMISSION

The start/stop character case selections below are valid for the entire Codabar family:

transmit start/stop characters in lower case

ÌADA0_Î transmit start/stop characters in upper case

ÌADA1cÎ

90

Page 97

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

MSI ‹ disable the family

ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control

ÌAE1XÎ MOD10 check digit control no check digit transmission

ÌAE2[Î MOD10 check digit control check digit transmission

ÌAE3^Î MOD11 - MOD10 check digit control no check digit transmission

ÌAE4aÎ MOD11 - MOD10 check digit control check digit transmission

ÌAE5dÎ MOD10 - MOD10 check digit control no check digit transmission

ÌAE6gÎ MOD10 - MOD10 check digit control check digit transmission

ÌAE7jÎ 91

Page 98

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

PLESSEY ‹ disable the family

ÌAF0WÎ Enable the code by selecting one of the check digit selections.

Standard Plessey no check digit control

ÌAF117Î check digit control check digit transmitted

ÌAF12;Î check digit control check digit not transmitted

ÌAF13?Î Anker Plessey no check digit control

ÌAF21:Î check digit control check digit transmitted

ÌAF22>Î check digit control check digit not transmitted

ÌAF23BÎ 92

Page 99

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

TELEPEN ‹ disable the family

ÌAL0cÎ Enable the code by selecting one of the check digit selections.

Numeric Telepen no check digit control

ÌAL11CÎ check digit control check digit transmitted

ÌAL12GÎ check digit control check digit not transmitted

ÌAL13KÎ Alphanumeric Telepen no check digit control

ÌAL21FÎ check digit control check digit transmitted

ÌAL22JÎ check digit control check digit not transmitted

ÌAL23NÎ 93

Page 100

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

DELTA IBM ‹ disable the family

ÌAH0[Î Enable the code by selecting one of the check digit selections.

no check digit control

ÌAH1^Î

Type 1 check digit control

ÌAH2aÎ

Type 2 check digit control

ÌAH3dÎ

94

Ì$-?Î

Page 101

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CODE 11 ‹ disable the family

ÌAG0YÎ Enable the code by selecting one of the check digit selections. no check digit control

ÌAG1\Î Type C check digit control check digit transmitted

ÌAG21<Î Type C check digit control check digit not transmitted

ÌAG22@Î Type K check digit control check digit transmitted

ÌAG31?Î Type K check digit control check digit not transmitted

ÌAG32CÎ Type C and Type K check digit control check digits transmitted

ÌAG41BÎ Type C and Type K check digit control check digits not transmitted

ÌAG42FÎ

95

Page 102

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CODE 16K

‹ disable the code

ÌAJ0_Î

Code 16K

ÌAJ1bÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.

CODE 49

‹ disable the code

ÌAM0eÎ

Code 49

ÌAM1hÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.

96

Page 103

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

GS1 DATABAR™ ‹ disable the family

ÌAQ0mÎ DISABLE CODE ENABLE CODE disable RSS Expanded Linear and Stacked

ÌAQ10IÎ enable RSS Expanded Linear and Stacked

ÌAQ11MÎ disable RSS Limited

ÌAQ20LÎ enable RSS Limited

ÌAQ21PÎ disable RSS 14 Linear and Stacked

ÌAQ30OÎ enable RSS 14 Linear and Stacked

ÌAQ31SÎ To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.

97

Page 104

ADVANCED FORMATTING NOT FOR PEN INTERFACES

~ ~

CONCATENATION ADVANCED FORMATTING

~ ~

Please follow the setup procedure carefully for these parameters. NOTE

The Advanced Formatting parameters may not be compatible with the IBM USB POS interface selection. NOTE

1. 2.

Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given. = Read the code and follow the procedure given ‹

3. 98

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of page.