Page 10
4 INTERFACE AND POWER 4.1 DC Inputs Sixteen TTL-Level DC Inputs are provided for interface either directly with TTL-Level equipment or with high voltage AC or DC equipment by using solid state relays (such as Opto-22 IAC5 for 90 - 140 VAC input). The DC Input specifications are shown in Table 2. Table 2, DC Input Specifications Logical One Input Voltage Logical Zero Input Voltage, - 2.0V min 0.8V max
Compatible with Opto 22 module types IAC5, IAC5A, IDC5, IDC5B, IDC5D, IDC5G.
Figure 2, Simplified DC Input Circuit
6
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 11
4.2 DC Outputs Sixteen TTL-Level DC outputs are provided for interface either directly with TTL-Level equipment or with high voltage AC or DC equipment by using solid state relays (such as Opto-22 OAC5 for 90 - 140 VAC output). The DC Output specifications are shown in Table 3. Table 3, DC Output Specifications Logical One Output Voltage, Logical Zero Output Voltage, 3.0V min at Current (Sourcing) = +2.5mA 0.4V min at Current (Sinking) = -2.5mA 1.5V min at Current (Sinking) = +12mA
Compatible with Opto 22 module types OAC5, OAC5A, OAC5A5, ODC5, ODC5A
Figure 3, Simplified DC Output Circuit
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
7
Page 12
4.3 64-pin DIN Connector Pinouts Connections between the Eurocard Controller, the user’s host computer, the 32 I/O points, and 24 Volt supply voltage are via the 64-pin DIN type connector, as listed in Table 4. Table 4, 64-pin DIN Pinouts Row A Pin # 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Row C Pin # 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31
Function Input 0 Input 1 Input 2 Input 3 Input 4 Input 5 Input 6 Input 7 Input 8 Input 9 Input 10 Input 11 Input 12 Input 13 Input 14 Input 15 Antenna 0 Pin 1 Antenna 0 Pin 2 Antenna 0 Pin 3 Antenna 0 Pin 4 Antenna 1 Pin 1 Antenna 1 Pin 2 Antenna 1 Pin 3 Antenna 1 Pin 4 Antenna 2 Pin 1 Antenna 2 Pin 2 Antenna 2 Pin 3 Antenna 2 Pin 4 Antenna 3 Pin 1 Antenna 3 Pin 2 Antenna 3 Pin 3 Antenna 3 Pin 4
2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32
Function Output 0 Output 1 Output 2 Output 3 Output 4 Output 5 Output 6 Output 7 Output 8 Output 9 Output 10 Output 11 Output 12 Output 13 Output 14 Output 15 Port 1 RS232 TX Port 1 RS232 RX Signal Ground Port 1 RS422 TX+ Port 1 RS422 TXPort 1 RS422 RX+ Port 1 RS422 RXPort 2 RS232 TX Port 2 RS232 RX Signal Ground Port 2 RS422 TX+ Port 2 RS422 TXPort 2 RS422 RX+ Port 2 RS422 RX+ 24 Volt DC Ground
Ground Lug = Frame Ground NOTE: Cable shields should be connected to Frame Ground on one end only.
8
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 13
4.4 DIP Switch Settings Switch 1, position 1, controls the Input/Output polarity of the connector pins on the HS870. With switch position 1 ON, outputs and inputs are inverted so that OUTPORT1=0 will set the pins on the connector HIGH. Conversely, with switch position 1 OFF, OUTPORT1=0 will set the pins LOW. The HS876 uses Switch 1, position 1 as follows: Switch 1 0 1 Mode Monitor Run Switch positions 2-8 are reserved for future use on both the HS870 and HS876.
4.5 Power Requirements The HS870-Series Controller must be powered by a power supply capable of providing 250 mA at 21 - 28 Volts DC to the Controller. The specifications on the input power at the Eurocard Controller terminals are: Input Voltage, 21 to 28 Volts DC Maximum Ripple, peak-to-peak ripple 2% of DC voltage Maximum Current, 300 mA
4.6 Serial Communication Protocols The HS870-Series Controller has the following communications options available : Interfaces, RS232, RS422 Baud Rates - 300, 1200, 2400, 4800, 9600, 19200 Parity, None, Even, Odd Data Bits, 7, 8 bits Stop Bits, 1
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
9
Page 14
4.7 RS232 Interface The connections for the RS232 interface are RS232 TX (Data from the Eurocard Controller), RS232 RX (Data to the Eurocard Controller) and Signal Ground, as shown in Figure 4. The signals and electrical loads on the RS232 TX and RS232 RX pins should conform to the electrical specifications of EIA Standard RS232. The maximum cable length specified under the EIA RS232 Standard is 50 feet. Good quality shielded cable should be used for these connections.
Figure 4, RS232C Connections
10
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 15
4.8 RS422 Interface The RS422/485 mode is recommended for electrically noisy environments. The connections are RS422/485 TX+ and RS422/485 TX(Data from the Eurocard Controller) and RS422/485 RX+ and RS422/485 RX- (Data to the Eurocard Controller), as shown in Figure 5. For maximum margin at very long line lengths (over 1000 feet), a 1/4 watt, 180 ohm (±5%) terminating resistor should be provided by the user across the RS422/485 RX+ and RS422/485 RX- lines at the Eurocard Controller, and across the RS422/485 TX+ and RS422/485 TX- lines at the host. The signals and electrical loads on the pins, as well as the characteristics of the shielded twisted pair cable must conform to the electrical specifications of EIA Standard RS422. The maximum recommended length of the RS422 connection is 4000 feet. Good
Figure 5, RS422 Connections quality shielded cable should be used for these connections. Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
11
Page 16
5 ANTENNA INTERFACE 5.1 Connection to EMS Antennas The Eurocard Controller can control up to four EMS Antennas. The connections to the Antennas are shown in Figure 6. Good quality shielded cable should be used for these connections. Installations with distances of 50’ or less may use a 3-pair cable such as Belden 9830 for signal and power. Applications over longer distances may require a 2-pair cable, such as Belden 9829, with a separate power ca-
Figure 6, Connections to EMS Antennas ble.
12
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 17
A APPENDIX: MODELS & ACCESSORIES The following table lists the available models and accessories for the HS870-Series RFID controller.
Table 5, Models and Accessories Available Models HS870B-4, HS876B-4, Accessories HS403BH HS403BL HS640B-870*, - - HS641B-870*, SP1012, BASIC Programmable Controller, for four Antennas. C Programmable Controller, for four Antennas. Industrial I/O Board for HS87X, Current-Sourcing. Industrial I/O Board for HS87X, Current-Sinking. Single card enclosure for HS87X, provides 32 TTL-level I/O. Two card enclosure for HS87XB and HS403, provides 32 industrial-level I/O. C Development Package for HS876
*Does not include controller board or I/O board.
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
13
Page 18
NOTES:
14
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller