Page 1
OPERATOR’S MANUAL
HS870-Series Programmable Eurocard Controller
Manual Rev 7, 9-98 iG Publication # 17-1017
Page 2
Escort Memory Systems Warranty Escort Memory Systems warrants that all products of its own manufacture conform to Escort Memory Systems specifications and are free from defects in material and workmanship when used under normal operating conditions and within the service conditions for which they were furnished. The obligation of Escort Memory Systems hereunder shall expire one (1) year after delivery, unless otherwise specified, and is limited to repairing, or at its option, replacing without charge, any such product which in Escort Memory Systems’s sole opinion proves to be defective within the scope of this Warranty. In the event Escort Memory Systems is not able to repair or replace defective products or components within a reasonable time after receipt thereof, Buyers shall be credited for their value at the original purchase price. Escort Memory Systems must be notified in writing of the defect or nonconformity within the warranty period and the affected product returned to Escort Memory Systems factory or to an authorized service center within thirty (30) days after discovery of such defect or nonconformity. Shipment shall not be made without prior authorization by Escort Memory Systems. This is Escort Memory Systems’s sole warranty with respect to the products delivered hereunder. No statement, representation, agreement or understanding oral or written, made by an agent, distributor, representative, or employee of Escort Memory Systems which is not contained in this warranty, will be binding upon Escort Memory Systems, unless made in writing and executed by an authorized Escort Memory Systems employee. Escort Memory Systems makes no other warranty of any kind whatsoever, expressed or implied, and all implied warranties of merchantability and fitness for a particular use which exceed the aforestated obligation are hereby disclaimed by Escort Memory Systems and excluded from this agreement. Under no circumstances shall Escort Memory Systems be liable to Buyer, in contract or in tort, for any special, indirect, incidental, or consequential damages, expenses, losses or delay however caused. Equipment or parts which have been subject to abuse, misuse, accident, alteration, neglect, unauthorized repair or installation are not covered by warranty. Escort Memory Systems shall make the final determination as to the existence and cause of any alleged defect. No liability is assumed for expendable items such as lamps and fuses. No warranty is made with respect to custom equipment or products produced to Buyer’s specifications except as specifically stated in writing by Escort Memory Systems in the contract for such custom equipment. This warranty is the only warranty made by Escort Memory Systems with respect to the goods delivered hereunder, and may be modified or amended only by a written instrument signed by a duly authorized officer of Escort Memory Systems and accepted by the Buyer. Extended warranties of up to four years are available for purchase for most EMS products. Contact EMS or your distributor for more information.
This document contains proprietary information which is protected by copyright. All rights are reserved. The information in this manual has been carefully checked and is believed to be accurate; however, no responsibility is assumed for possible inaccuracies or omissions. Specifications are subject to change without notice. EMS®, Escort Memory Systems® and the EMS® logo are registered trademarks of Escort Memory Systems, a Datalogic Group Company. Other brand and product names mentioned are trademarks or registered trademarks of their respective holders. Escort Memory Systems, Inc. A Datalogic Group Company 3 Victor Square Scotts Valley, CA 95066 Telephone (408) 438-7000 FAX (831) 438-5768 BBS (831) 438-3250 www.ems-rfid.com ii
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 3
TABLE OF CONTENTS 1
INTRODUCTION
1
2
GETTING STARTED
2
2.1 Programmable Controller Software . . . . . . . . . 2 2.2 Evaluation Cable Connections . . . . . . . . . . . 2 2.3 Exercising the Controller . . . . . . . . . . . . . . 2
3
SPECIFICATIONS AND DIMENSIONS
3
3.1 HS870-Series Specifications . . . . . . . . . . . . 3 3.2 LED Indicators . . . . . . . . . . . . . . . . . . . 4
4
INTERFACE AND POWER 4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8
5
6
DC Inputs . . . . . . . . . . . . . . . . . . . . . . 6 DC Outputs . . . . . . . . . . . . . . . . . . . . . 7 64-pin DIN Connector Pinouts . . . . . . . . . . . 8 DIP Switch Settings . . . . . . . . . . . . . . . . . 9 Power Requirements . . . . . . . . . . . . . . . . 9 Serial Communication Protocols . . . . . . . . . . 9 RS232 Interface . . . . . . . . . . . . . . . . . . . 10 RS422 Interface . . . . . . . . . . . . . . . . . . . 11
ANTENNA INTERFACE
12
5.1 Connection to EMS Antennas . . . . . . . . . . . . 12
A
APPENDIX: MODELS & ACCESSORIES
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
13 iii
Page 4
iv
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 5
1 INTRODUCTION Escort Memory Systems provides a complete family of field-proven Read/Write Radio-Frequency Identification (RFID) products. The system consists of Tags, Reader/Writers, Controllers, Antennas, and ancillary equipment. Tags can be attached to a product or its carrier and act as an electronic identifier, job sheet, portable database or manifest. They are read and updated via a Escort Memory Systems Reader/Writer or Controller and Antenna through non-conductive materials while moving or standing still. The HS870-Series Eurocard Controller incorporates high-level language capability, two fully-buffered bi-directional serial ports, a 16K byte non-volatile file system, 32K bytes of RAM, 32 TTL-level I/O points and an interface of up to four HS-Series Antennas. The connection between the Controller and each Antenna is via two twisted pair wires (four wires) with a maximum cable length of 1,200 meters. Ten status LEDs are mounted on the front of the Controller to aid in system debug and maintenance. Programs can be created in BASIC or C on a PCcompatible computer using any editor and downloaded to the Controller. The HS403B Industrial I/O board can be used to convert the TTLlevel signals on the HS870-Series to 24VDC optically-isolated industrial I/O.
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
1
Page 6
2 GETTING STARTED To become familiar with the operation of the HS870-Series Controllers, read the instruction manuals completely and exercise the system using either a standard ASCII terminal or an IBM Personal Computer (PC) or a compatible computer using the software available from Escort Memory Systems.
2.1 Programmable Controller Software See the appropriate Development Package for details.
2.2 Evaluation Cable Connections To exercise the Controller using a standard terminal or IBM PCCompatible host computer, insert the Controller into an HS640B-870 Eurocard Enclosure. The Controller may also be used with an HS403 Eurocard Industrial I/O Board, which provides 24 Volt optically isolated I/O. The Controller and I/O board would then be mounted in an HS641B-870 2-Card Enclosure. Connect the terminal blocks on the rack to the COM1: serial port of the computer, to a 24 Volt power supply, and to an HS-Series Antenna according to the pinouts given in this manual.
2.3 Exercising the Controller Once the connections are properly made, set the terminal to 9600 baud, no parity, 8 data bits (the default settings of the Controller) and connect the Controller to the evaluation cable. A prompt will appear on the terminal screen indicating that the Controller is ready to respond to commands. The programs available on the Controller can be quickly seen by typing a FILES command.
2
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 7
3 SPECIFICATIONS AND DIMENSIONS 3.1 HS870-Series Specifications Table 1 lists the specifications for the HS870-Series Eurocard. Table 1, HS870-Series Specifications Electrical Supply Voltage Max. Current Max. Ripple Memory EEPROM RAM *
Interface With Antenna Max. Cable Length Typical Data Transfer Rate Input/Output Communication With Host Interface Options Baud Rate Parity Data Bits Stop Bits Mechanical Specifications Dimensions (W× H × D) Connector, Indicators Environment Operating Temp Storage Temp Humidity Protection Class, 21 to 28 VDC, 300 mA, 2% of DC voltage, 32K bytes, 32K bytes, for user variables and programs, 4,000 ft. (1,200 m), 3,000 bytes/second, 32 DC I/O points, TTL-level, Two RS232 or RS422 bi-directional serial ports, 300, 1200, 4800, 9600, 19200, Odd, Even or None, 7 or 8, 1, 3.9 × 6.3 in. (100 × 160 mm) 64-pin DIN (32 x 2), On, Error, RX, TX and Antenna LEDs, +32 to +140°F (0 to +60°C), -40 to +185°F (-40 to +85°C), 5% to 95% non-condensing, NEMA 1 in HS640 or HS641 enclosure
*Static RAM is battery-backed in the HS876.
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
3
Page 8
3.2 LED Indicators Ten LEDs are mounted on the front of the Eurocard Controller for status indication as shown in Figure 1. The LEDS function as follows: ON, The ON LED emits RED whenever the Controller is powered.
ER(Error), The ER LED emits RED light to indicate that the Controller is reset or fails self-test.
RX1(Receive), The RX1 LED emits GREEN light when data is being received by the Controller on serial port 1.
inches All dimensions are in mm
Figure 1, Controller Layout
4
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
Page 9
TX1(Transmit), The TX1 LED emits GREEN light when data is being transmitted from the Controller to the host on serial port 1.
RX2(Receive), The RX2 LED emits GREEN light when data is being received by the Controller on serial port 2.
TX2 (Transmit), The TX2 LED emits GREEN light when data is being transmitted from the Controller to the host on serial port 2. A0-A3, The A0 - A3 LEDs emit YELLOW (Antennas) light whenever the corresponding Antenna is transmitting.
Copyright © 1998 Escort Memory Systems Inc. HS870-Series Programmable Controller
5